Engineering Papers⌕ Search

Engineering topics

Mannion, Danielle R.

Publications and source records attributed to Mannion, Danielle R..

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical Assessment of Impurities Found in Process Gases using the InfiTOF, a High Resolution, Low Mass, Variable Time-of-Flight Mass Spectrometer

The JEOL InfiToF is a high-resolution, low mass (HRLM) mass spectrometer (MS) with the application potential to meet analytical needs for tritium handling systems, such as those at the Savannah River Tritium Facilities (SRTE) and those used in fusion research. The Service Level Agreement (SLA) #144 line 27 “InfiTOF R&D” has concluded its first year of efforts under Tritium Recycle and Renewal. The project goals for FY22 were: (1) Production of a finalized modification list for tritium hardened components in the InfiTOF, (2) perform an assessment on impurity gases commonly found in process gases from Tritium Facilities and (3) begin developing a set of standardized work instructions that will be used as a basis for operations on the InfiTOF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

LDRD External Report Summary

Matrix-Assisted Ionization is a new and highly promising mass spectrometry technique for rapid analysis of uranium; however, the chemistry and physics underlying this ionization mechanism are largely unknown. This effort seeks to understand the fundamental ionization phenomena by characterizing both ionization matrix materials themselves and analyte chemistry ionization trends.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗