Engineering Papers⌕ Search

Engineering topics

Mandjavidze, I.

Publications and source records attributed to Mandjavidze, I..

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

Design, construction, and performance of the GEM based radial time projection chamber for the BONuS12 experiment with CLAS12

Here, a new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar devices constructed for previous experiments, including cylindrical amplification layers constructed from single continuous GEM foils with less than 1% dead area. Particular attention had been paid to producing excellent geometric uniformity of all electrodes, including the very thin metalized polyester film of the cylindrical cathode. This manuscript describes the design, construction, and performance of this new detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring strips. However, to effectively extract the inherent positional information, the lateral spacing of the straight strips must be comparable to or preferably smaller than the full extent of the incident charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the incident charge with a pitch appreciably larger than the charge cloud.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CLAS12 Data Acquisition System

The CLAS12 Data Acquisition System was designed and built as part of the CLAS12 detector project in Hall B at Jefferson Laboratory. This article contains a full description of the system, including requirements, design, hardware, and software descriptions, as well as the achieved performance. The associated computing, network, and slow controls systems are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Test Beam Facility Annual Report: FY19

This Technical Memorandum (TM) summarizes the Fermilab Test Beam Faciltiy (FTBF) operations for FY2019. It is one of a series of annual publications intended to gather information in one place. This TM discusses the experiments performed at the Test Beam from November 2018 to July 2019. The experiments are listed in Table 1. Each experiment wrote a summary that was edited for clarity and is included in this report.

43 PARTICLE ACCELERATORS↗

The CLAS12 Forward Tagger

This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO$_4$ crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2$^\circ$ to 5$^\circ$ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Micromegas Vertex Tracker

The Micromegas Vertex Tracker was designed to improve upon the tracking capabilities of the baseline design of the CLAS12 spectrometer in Hall~B at Jefferson Laboratory. A Barrel Micromegas Tracker made with six concentric cylinders, each made of three 120$^\circ$-sector tiles, surrounds the Silicon Vertex Tracker, and a Forward Micromegas Tracker composed of 6 disks is placed 30~cm downstream of the liquid-hydrogen target. Both trackers sit in a 5~T solenoid magnetic field. All Micromegas elements are based on resistive technology to withstand luminosities up to $10^{35}$~cm$^{-2}$s$^{-1}$, as well as on bulk technology to enforce gain uniformity and mechanical robustness. Due to the high magnetic field, dedicated electronics have been designed and displaced $\sim$2~m away from the detectors. The electronics readout is based on the DREAM ASICs that allow sustained operation up to 20~kHz trigger rate at the maximum luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ASACUSA Micromegas Tracker: A cylindrical, bulk Micromegas detector for antimatter research

The ASACUSA Micromegas Tracker (AMT; ASACUSA: Atomic Spectroscopy and Collisions Using Slow Antiprotons) was designed to be able to reconstruct antiproton-nucleon annihilation vertices in three dimensions. The goal of this device is to study antihydrogen formation processes in the ASACUSA cusp trap, which was designed to synthesise a spin-polarised antihydrogen beam for precise tests of Charge, Parity, and Time (CPT) symmetry invariance. This paper discusses the structure and technical details of an AMT detector built into such an environment, its data acquisition system and the first performance with cosmic rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The readout system for the Clas12 Micromegas vertex tracker

In this paper, the architecture of the Clas12 Micromegas vertex tracker readout is described and the details of its implementation are given. The innovations allowing to meet the challenging requirements of the tracker operation are presented. The system performance is evaluated based on detector tests with a cosmic rays trigger and on standalone high rate validation tests. Finally, the perspectives to adapt the readout system or a part of it to other experiments are discussed.

Attie, D.↗