Engineering Papers⌕ Search

Engineering topics

Mamedov, F.

Publications and source records attributed to Mamedov, F..

Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from weakly interacting massive particle (WIMP) dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C3F8 scale in accordance with a new nucleation mechanism, rather than one driven by a hot spike as previously supposed. Using this semiempirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c-2 and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c-2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

Final results are reported from operation of the PICO-60 C3F8 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.2×10-41 cm2 for a 25 GeV WIMP, improving on previous PICO results for 3–5 GeV WIMPs by an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calorimeter development for the SuperNEMO double beta decay experiment

SuperNEMO is a double-β decay experiment, which will employ the successful tracker–calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-β decay isotope, reaching a sensitivity to the neutrinoless double-β decay (Ovββ) half-life of the order of 10 26 yr, corresponding to a Majorana neutrino mass of 50–100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, ΔE/E, around 3%/ $\sqrt{E9MeV)}$σ, or 7% $\sqrt{E9MeV)}$ FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. Here, we describe the R&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Matter Search Results from the PICO - 60 C 3 F 8 Bubble Chamber

New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C 3 F 8 located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C 3 F 8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. In conclusion, these results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10 -41 cm 2 for a 30-GeV c -2 WIMP, more than 1 order of magnitude improvement from previous PICO results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 2 ν β β decay half-life and search for the 0 ν β β decay of Cd 116 with the NEMO-3 detector

The NEMO-3 experiment measured the half-life of the 2νββ decay and searched for the 0νββ decay of 116 Cd. Using 410 g of 116 Cd installed in the detector with an exposure of 5.26 y, (4968±74) events corresponding to the 2νββ decay of 116 Cd to the ground state of 116 Sn have been observed with a signal to background ratio of about 12. The half-life of the 2νββ decay has been measured to be T 2ν 1/2 = [2.74 ± 0.04(stat) ± 0.18(syst)] × 10 19 y. No events have been observed above the expected background while searching for 0νββ decay. The corresponding limit on the half-life is determined to be T 0ν 1/2 ≥ 1.0 × 10 23 y at the 90% C.L. which corresponds to an upper limit on the effective Majorana neutrino mass of < m ν > ≤ 1.4–2.5 eV depending on the nuclear matrix elements considered. As a result, limits on other mechanisms generating 0νββ decay such as the exchange of R-parity violating supersymmetric particles, right-handed currents and majoron emission are also obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact anti-radon facility

Suppression of radon background is one of main tasks in ultra-low background experiments. The most promising technique for suppression of radon is its adsorption on charcoal. Within the frame of the NEMO-3 experiment, radon trapping facility (RTF) was installed in Modane underground laboratory in 2004. Based on long-term experience with this facility a new compact transportable anti-radon facility was constructed in cooperation among IEAP CTU, SÚRO and ATEKO company. The device provides 20m{sup 3}/h of purified air (air radon activity at the output ∼10mBq/m{sup 3}). The basic features and preliminary results of anti-radon device testing are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present status of sensitive detector of reactor’s antineutrinos using scintillating detectors

In 2011, the reanalysis of the reactor antineutrinos spectra led to the formulation of the Reactor Antineutrino Anomaly (RAA) [1], which indicates the discrepancy between measured and expected antineutrino fluxes on short baselines. This discrepancy appears to favor the existence of the fourth “sterile” neutrino with |Δm{sup 2}|>1 eV{sup 2}. To confirm or reject this hypothesis a high sensitive antineutrino detector located close to the reactor is required. In addition to that such a detector could be used to online monitor the isotopic composition of the reactor core and to prevent illegal production and removal of{sup 239}Pu, which is the essential part of nuclear weapons. Detector DANSSino [2] already proved that even a compact antineutrino detector (∼ 1 m{sup 3}) based on polystyrene is capable of antineutrino detection in the close vicinity of a reactor core (∼ 10 m) with signal to background ratio about one. As a common activity between JINR Dubna and IEAP CTU a new prototype of detector (called S{sup 3}) has been proposed and is under construction. The construction design, selected results of Monte Carlo simulations and results of benchmark tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗