Maltz, Jonathan S.

Publications and source records attributed to Maltz, Jonathan S..

Assessing endothelial function using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve applying to the artery a substantially constant external pressure that causes the tension in the arterial wall to be reduced, where the pressure is provided via a cuff adjacent to and/or around a region of the mammal's body; determining, over the course of one or more cardiac cycles, changes in pressure in the cuff resulting from cardiac activity of the mammal to establish a baseline value for a parameter related to endothelial function in the mammal; applying a stimulus to the mammal; determining, over the course of one or more cardiac cycles, changes in pressure in the cuff resulting from cardiac activity of the mammal to establish a stimulus-effected value for a parameter related to endothelial function in the mammal; wherein the baseline value is determined from measurements made when the mammal is not substantially effected by the stimulus; and wherein differences in the baseline value and the stimulus-effected value provide a measure of endothelial function in the mammal.

Maltz, Jonathan S.↗

Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (Pm); b) applying a stimulus to the subject; and applying external pressure Pm to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (Pm); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (P.sub.m); b) applying a stimulus to the subject; and applying external pressure P.sub.m to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (P.sub.m); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (P.sub.m); b) applying a stimulus to the subject; and applying external pressure P.sub.m to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (P.sub.m); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

60 APPLIED LIFE SCIENCES↗

Web-based visual data exploration for improved radiological source detection

Radiation detection can provide a reliable means of detecting radiological material. Such capabilities can help to prevent nuclear and/or radiological attacks, but reliable detection in uncontrolled surroundings requires algorithms that account for environmental background radiation. The Berkeley Data Cloud (BDC) facilitates the development of such methods by providing a framework to capture, store, analyze, and share data sets. In the era of big data, both the size and variety of data make it difficult to explore and find data sets of interest and manage the data. Thus, in the context of big data, visualization is critical for checking data consistency and validity, identifying gaps in data coverage, searching for data relevant to an analyst's use cases, and choosing input parameters for analysis. Downloading the data and exploring it on an analyst's desktop using traditional tools are no longer feasible due to the size of the data. This study describes the design and implementation of a visualization system that addresses the problems associated with data exploration within the context of the BDC. Finally, the visualization system is based on a JavaScript front end communicating via REST with a back end web server.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Image quality improvement in megavoltage cone beam CT using an imaging beam line and a sintered pixelated array system

Purpose: To quantify the improvement in megavoltage cone beam computed tomography (MVCBCT) image quality enabled by the combination of a 4.2 MV imaging beam line (IBL) with a carbon electron target and a detector system equipped with a novel sintered pixelated array (SPA) of translucent Gd{sub 2}O{sub 2}S ceramic scintillator. Clinical MVCBCT images are traditionally acquired with the same 6 MV treatment beam line (TBL) that is used for cancer treatment, a standard amorphous Si (a-Si) flat panel imager, and the Kodak Lanex Fast-B (LFB) scintillator. The IBL produces a greater fluence of keV-range photons than the TBL, to which the detector response is more optimal, and the SPA is a more efficient scintillator than the LFB. Methods: A prototype IBL + SPA system was installed on a Siemens Oncor linear accelerator equipped with the MVision{sup TM} image guided radiation therapy (IGRT) system. A SPA strip consisting of four neighboring tiles and measuring 40 cm by 10.96 cm in the crossplane and inplane directions, respectively, was installed in the flat panel imager. Head- and pelvis-sized phantom images were acquired at doses ranging from 3 to 60 cGy with three MVCBCT configurations: TBL + LFB, IBL + LFB, and IBL + SPA. Phantom image quality at each dose was quantified using the contrast-to-noise ratio (CNR) and modulation transfer function (MTF) metrics. Head and neck, thoracic, and pelvic (prostate) cancer patients were imaged with the three imaging system configurations at multiple doses ranging from 3 to 15 cGy. The systems were assessed qualitatively from the patient image data. Results: For head and neck and pelvis-sized phantom images, imaging doses of 3 cGy or greater, and relative electron densities of 1.09 and 1.48, the CNR average improvement factors for imaging system change of TBL + LFB to IBL + LFB, IBL + LFB to IBL + SPA, and TBL + LFB to IBL + SPA were 1.63 (p < 10{sup -8}), 1.64 (p < 10{sup -13}), 2.66 (p < 10{sup -9}), respectively. For all imaging doses, soft tissue contrast was more easily differentiated on IBL + SPA head and neck and pelvic images than TBL + LFB and IBL + LFB. IBL + SPA thoracic images were comparable to IBL + LFB images, but less noisy than TBL + LFB images at all imaging doses considered. The mean MTFs over all imaging doses were comparable, at within 3%, for all imaging system configurations for both the head- and pelvis-sized phantoms. Conclusions: Since CNR scales with the square root of imaging dose, changing from TBL + LFB to IBL + LFB and IBL + LFB to IBL + SPA reduces the imaging dose required to obtain a given CNR by factors of 0.38 and 0.37, respectively. MTFs were comparable between imaging system configurations. IBL + SPA patient image quality was always better than that of the TBL + LFB system and as good as or better than that of the IBL + LFB system, for a given dose.

61 RADIATION PROTECTION AND DOSIMETRY↗