Engineering Papers⌕ Search

Engineering topics

Mairani, Andrea

Publications and source records attributed to Mairani, Andrea.

The FLUKA code: Overview and new developments

The FLUKA Monte Carlo Radiation Transport and Interaction code package is widely used to simulate the interaction of particles with matter in a variety of fields, including high energy physics, space radiation, medical applications, radiation protection and shielding assessments, accelerator studies, astrophysical studies and well logging. This paper gives a brief overview of the FLUKA program and describes recent developments, in particular, improvements in the modelling of particle interactions and transport are described in detail. In addition, an overview of selected applications is given.

Ballarini, Francesca↗

Deciphering Time-Dependent DNA Damage Complexity, Repair, and Oxygen Tension: A Mechanistic Model for FLASH-Dose-Rate Radiation Therapy

Irradiation with ultrahigh dose rates (FLASH) has reemerged as a promising radiation therapy approach to effectively lower potential damage burden on normal tissue without sacrificing tumor control. However, the large number of recent FLASH studies have been conducted under vastly different experimental conditions and circumstances (ie, investigated biological endpoint, radiation quality, and environmental oxygen level), with unverified biological mechanisms of action and unexplored interplay effect of the main dependencies. To facilitate radiobiological investigation of FLASH phenomena and assessment of clinical applicability, we present an extension of the mechanistic radiobiological model “UNified and VERSatile bio response Engine” (UNIVERSE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Biological Modeling for Voxel-based Heavy Ion Treatment Planning Using the Mechanistic Repair-Misrepair-Fixation Model and Nuclear Fragment Spectra

Purpose: The physical and biological differences between heavy ions and photons have not been fully exploited and could improve treatment outcomes. In carbon ion therapy, treatment planning must account for physical properties, such as the absorbed dose and nuclear fragmentation, and for differences in the relative biological effectiveness (RBE) of ions compared with photons. We combined the mechanistic repair-misrepair-fixation (RMF) model with Monte Carlo-generated fragmentation spectra for biological optimization of carbon ion treatment plans. Methods and Materials: Relative changes in double-strand break yields and radiosensitivity parameters with particle type and energy were determined using the independently benchmarked Monte Carlo damage simulation and the RMF model to estimate the RBE values for primary carbon ions and secondary fragments. Depth-dependent energy spectra were generated with the Monte Carlo code FLUKA for clinically relevant initial carbon ion energies. The predicted trends in RBE were compared with the published experimental data. Biological optimization for carbon ions was implemented in a 3-dimensional research treatment planning tool. Results: We compared the RBE and RBE-weighted dose (RWD) distributions of different carbon ion treatment scenarios with and without nuclear fragments. The inclusion of fragments in the simulations led to smaller RBE predictions. A validation of RMF against measured cell survival data reported in published studies showed reasonable agreement. We calculated and optimized the RWD distributions on patient data and compared the RMF predictions with those from other biological models. The RBE values in an astrocytoma tumor ranged from 2.2 to 4.9 (mean 2.8) for a RWD of 3 Gy(RBE) assuming (α/β){sub X} = 2 Gy. Conclusions: These studies provide new information to quantify and assess uncertainties in the clinically relevant RBE values for carbon ion therapy based on biophysical mechanisms. We present results from the first biological optimization of carbon ion radiation therapy beams on patient data using a combined RMF and Monte Carlo damage simulation modeling approach. The presented method is advantageous for fast biological optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of FLUKA Monte Carlo Code for Nuclear and Accelerator Physics

FLUKA is a general purpose Monte Carlo code capable of handling all radiation components from thermal energies (for neutrons) or 1 keV (for all other particles) to cosmic ray energies and can be applied in many different fields. Presently the code is maintained on Linux. The validity of the physical models implemented in FLUKA has been benchmarked against a variety of experimental data over a wide energy range, from accelerator data to cosmic ray showers in the Earth atmosphere. FLUKA is widely used for studies related both to basic research and to applications in particle accelerators, radiation protection and dosimetry, including the specific issue of radiation damage in space missions, radiobiology (including radiotherapy) and cosmic ray calculations. After a short description of the main features that make FLUKA valuable for these topics, the present paper summarizes some of the recent applications of the FLUKA Monte Carlo code in the nuclear as well high energy physics. In particular it addresses such topics as accelerator related applications.

43 PARTICLE ACCELERATORS↗