Engineering Papers⌕ Search

Engineering topics

Maekawa, Ryuji

Publications and source records attributed to Maekawa, Ryuji.

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗