Spatiotemporal migration of antiferromagnetic domain walls in Sr2IrO4
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Madsen, Anders.
Explore the source record for details and available documents.
Abstract Transient grating spectroscopy is a specialized application of the four-wave-mixing methodology and constitutes a versatile technique for investigating the dynamics of vibrational, magnetic and electronic degrees of freedom of matter in a background-free fashion. Recent developments in free-electron laser sources have enabled the extension of this technique into the extreme ultraviolet range. Ongoing efforts to expand transient grating spectroscopy into the x-ray regime promise numerous advantages: (1) substantial penetration depths that allow for probing bulk material properties, (2) element specificity via specific core-excited states, and (3) short wavelengths that allow for excitation gratings with higher momentum transfer and improved spatial resolution. In this study, we comprehensively outline the procedures for conducting x-ray transient grating pump/optical probe experiment. The process encompasses the design and alignment of the experimental setup, as well as the subsequent steps involved in data acquisition and analysis. This paper is intended as a comprehensive guide for researchers interested in implementing x-ray transient grating spectroscopy, providing valuable insights into the intricacies of the experimental workflow required for this novel technique. Furthermore, we discuss the potential for extending this methodology to an x-ray pump/x-ray probe scheme, envisioning a future direction that holds promise for enhancing the capabilities and scope of x-ray transient grating spectroscopy, opening new opportunities for studying ultrafast processes with unprecedented temporal and spatial resolutions.
High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV –1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.
Resonant oscillators with stable frequencies and large quality factors help us to keep track of time with high precision. Examples range from quartz crystal oscillators in wristwatches to atomic oscillators in atomic clocks, which are, at present, our most precise time measurement devices. The search for more stable and convenient reference oscillators is continuing. Nuclear oscillators are better than atomic oscillators because of their naturally higher quality factors and higher resilience against external perturbations. One of the most promising cases is an ultra-narrow nuclear resonance transition in 45 Sc between the ground state and the 12.4-keV isomeric state with a long lifetime of 0.47 s (ref. 10 ). The scientific potential of 45 Sc was realized long ago, but applications require 45 Sc resonant excitation, which in turn requires accelerator-driven, high-brightness X-ray sources that have become available only recently. Here we report on resonant X-ray excitation of the 45 Sc isomeric state by irradiation of Sc-metal foil with 12.4-keV photon pulses from a state-of-the-art X-ray free-electron laser and subsequent detection of nuclear decay products. Simultaneously, the transition energy was determined as ${\mathrm{12,389.59}}_{+0.12\left({\rm{syst}}\right)}^{\pm 0.15\left({\rm{stat}}\right)}\,{\rm{eV}}$ with an uncertainty that is two orders of magnitude smaller than the previously known values. These advancements enable the application of this isomer in extreme metrology, nuclear clock technology, ultra-high-precision spectroscopy and similar applications.
Higher-order statistical analysis of X-ray scattering from dilute solutions of polydisperse goethite nanorods was performed and revealed structural information which is inaccessible by conventional small-angle scattering. For instance, a pronounced temperature dependence of the correlated scattering from suspension was observed. The higher-order scattering terms deviate from those expected for a perfectly isotropic distribution of particle orientations, demonstrating that the method can reveal faint orientational order in apparently disordered systems. The observation of correlated scattering from polydisperse particle solutions is also encouraging for future free-electron laser experiments aimed at extracting high-resolution structural information from systems with low particle heterogeneity.
Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.
A precise spectral characterization of every single pulse is required in many x-ray free-electron laser (XFEL) experiments due to the fluctuating spectral content of self-amplified spontaneous emission (SASE) beams. Bent single-crystal spectrometers can provide sufficient spectral resolution to resolve the SASE spikes while also covering the full SASE bandwidth. To better withstand the high heat load induced by the 4.5 MHz repetition rate of pulses at the forthcoming European XFEL facility, a spectrometer based on single-crystal diamond has been developed. Here, we report a direct comparison of the diamond spectrometer with its Si counterpart in experiments performed at the Linac Coherent Light Source.
Abstract not provided
Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (UHRIX) has achieved 0.6 meV and 0.25 nm -1 spectral and momentum-transfer resolutions, respectively. However, further improvements down to 0.1 meV and 0.02 nm -1 are required to close the gap in energy–momentum space between high- and low-frequency probes. It is shown that this goal can be achieved by further optimizing the X-ray optics and by increasing the spectral flux of the incident X-ray pulses. UHRIX performs best at energies from 5 to 10 keV, where a combination of self-seeding and undulator tapering at the SASE-2 beamline of the European XFEL promises up to a 100-fold increase in average spectral flux compared with nominal SASE pulses at saturation, or three orders of magnitude more than what is possible with storage-ring-based radiation sources. Wave-optics calculations show that about 7 × 10 12 photons s -1 in a 90 µeV bandwidth can be achieved on the sample. This will provide unique new possibilities for dynamics studies by IXS.
Here, a structural understanding of whole cells in three dimensions at high spatial resolution remains a significant challenge and, in the case of X-rays, has been limited by radiation damage. By alleviating this limitation, cryogenic coherent diffractive imaging (cryo-CDI) can in principle be used to bridge the important resolution gap between optical and electron microscopy in bio-imaging. Here, the first experimental demonstration of cryo-CDI for quantitative three-dimensional imaging of whole frozen-hydrated cells using 8 Kev X-rays is reported. As a proof of principle, a tilt series of 72 diffraction patterns was collected from a frozen-hydrated Neospora caninum cell and the three-dimensional mass density of the cell was reconstructed and quantified based on its natural contrast. This three-dimensional reconstruction reveals the surface and internal morphology of the cell, including its complex polarized sub-cellular structure. Finally, it is believed that this work represents an experimental milestone towards routine quantitative three-dimensional imaging of whole cells in their natural state with spatial resolutions in the tens of nanometres.
In order to exploit the femtosecond pulse duration of X-ray Free-Electron Lasers (XFEL) operating in the hard X-ray regime for ultrafast time-resolved protein crystallography experiments, critical parameters that determine the crystallographic signal-to-noise (I/σI) must be addressed. For single-crystal studies under low absorbed dose conditions, it has been shown that the intrinsic pulse intensity stability as well as mode structure and jitter of this structure, significantly affect the crystallographic signal-to-noise. Here, geometrical parameters are theoretically explored for a three-beam scheme: X-ray probe, optical pump, X-ray probe (or “probe-pump-probe”) which will allow experimental determination of the photo-induced structure factor amplitude differences, ΔF, in a ratiometric manner, thereby internally referencing the intensity noise of the XFEL source. In addition to a non-collinear split-beam geometry which separates un-pumped and pumped diffraction patterns on an area detector, applying an additional convergence angle to both beams by focusing leads to integration over mosaic blocks in the case of well-ordered stationary protein crystals. Ray-tracing X-ray diffraction simulations are performed for an example using photoactive yellow protein crystals in order to explore the geometrical design parameters which would be needed. The specifications for an X-ray split and delay instrument that implements both an offset angle and focused beams are discussed, for implementation of a probe-pump-probe scheme at the European XFEL. We discuss possible extension of single crystal studies to serial femtosecond crystallography, particularly in view of the expected X-ray damage and ablation due to the first probe pulse.
Third-generation X-ray synchrotrons like the European Synchrotron Radiation Facility (ESRF) are optimized to produce intense undulator radiation. Insertion devices, such as undulators, ensure the highest possible brilliance--the key parameter for the success of e.g. coherent scattering, which is one of the main techniques employed at ESRF's TROIKA beamline. Nowadays, the constant efforts to reduce the emittance and improve the stability of the electron beam allow using small-gap insertion devices and increase the brilliance. Obviously, it is important to have an experimental technique for evaluating the performance of the undulator source. Here we present a method based on measuring the diffuse scattering from a light amorphous material by a photon counting detector. The measured spectral intensities show a very good agreement with the simulated spectra, demonstrating the high brilliance (above 10{sup 20} ph/s/0.1%bw/mrad{sup 2}/mm{sup 2}) achieved at modern facilities.
X-ray diffraction microscopy (XDM) is well suited for nondestructive, high-resolution biological imaging, especially for thick samples, with the high penetration power of x rays and without limitations imposed by a lens. We developed nonvacuum, cryogenic (cryo-) XDM with hard x rays at 8 keV and report the first frozen-hydrated imaging by XDM. By preserving samples in amorphous ice, the risk of artifacts associated with dehydration or chemical fixation is avoided, ensuring the imaging condition closest to their natural state. The reconstruction shows internal structures of intact D. radiodurans bacteria in their natural contrast.