Engineering Papers⌕ Search

Engineering topics

Madigan, Peter

Publications and source records attributed to Madigan, Peter.

Hydra Network Automatic Configuration (Hydra Autoconfig) v1

Hydra Autoconfig is an algorithm and software program to automatically configure a resilient network of independent ASICs that are capable of being connected as a Hydra network. The Hydra network itself is described in an invention disclosure titled: "Ad-Hoc Networks of Readout ASICs for Reliable Detector Instrumentation" (2020-091). The Hydra Autoconfig software works by first configuring a Hydra node. Then it recursively builds a Hydra network by attempting to link to each available upstream node in succession, keeping links that are verified. It then repeats on each newly generated node until no possible links remain. Once it is so configured, a reliable Hydra network of ASICs remains that can be reconfigured later to respond to damage or malfunction of one or more of the constituent ASICs.

Grace, Carl↗

A New Concept for Kilotonne Scale Liquid Argon Time Projection Chambers

We develop a novel Time Projection Chamber (TPC) concept suitable for deployment in kilotonne-scale detectors, with a charge-readout system free from reconstruction ambiguities, and a robust TPC design that reduces high-voltage risks while increasing the coverage of the light-collection system and maximizing the active volume. This novel concept could be used as a far detector module in the Deep Underground Neutrino Experiment (DUNE). For the charge-readout system, we used the charge-collection pixels and associated application-specific integrated circuits currently being developed for the liquid argon (LAr) component of the DUNE Near Detector design, ArgonCube. In addition, we divided the TPC into a number of shorter drift volumes, reducing the total voltage used to drift the ionization electrons, and minimizing the stored energy per TPC. Segmenting the TPC also contains scintillation light, allowing for precise trigger localization and a more expansive light-readout system. Furthermore, the design opens the possibility of replacing or upgrading components. These augmentations could substantially improve the reliability and the sensitivity, particularly for low-energy signals, in comparison to traditional monolithic LArTPCs with projective-wire charge readouts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Captain Electronics Technical Report

This report details the current layout of the electronics for the mini-CAPTAIN detector system, as well as the lessons learned during commissioning. We will present some electronics suggestions for future LArTPC systems. Mini-CAPTAIN is one of three detectors used in the Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAPTAIN) project at Los Alamos National Lab (LANL). The detector uses many of the same electronic components as current and developing LArTPC experiments. This includes the motherboards, service cards, amplifiers and ADC made by Brookhaven National Laboratory (BNL) and the front-end modules (FEM) made by Nevis Labs. The cold electronics performed well in both vacuum and cryogenic environments after months of exposure. Mini-CAPTAIN was tested with two liquid nitrogen and three liquid argon run cycles. The final testing was performed at the Weapons Neutron Research (WNR) facility at LANSCE. Mini-CAPTAIN was able to maintain a clean electrical signal through most of the test cycles. Most noise reduction was achieved with power source filtering and careful attention to the ground configuration. Direct oscilloscope probing on the front-end output provided the fastest analysis and correction of noise sources. Ground path assumptions and integrity were verified with frequent impedance checks. A high voltage break down event damaged some of the channels on the motherboards and a number of the wire decoupling capacitors. This temporarily introduced significant noise on the wire planes due to current leakage. The detector was taken apart and reassembled three times, with successful noise reduction after each activity. The current raw signal-to-noise ratio is 9 to 1.

42 ENGINEERING↗