A thermal scanning study of coastal upwelling in Lake Superior

The use of a thermal scanner to monitor the time evolution of the thermal structure of the coastal waters in Lake Superior during an upwelling event is described. Mosaics of thermal imagery from ten different times are described. Qualitative descriptions of the imagery give insight into the upwelling event. Recommendations for future use of a thermal scanner to monitor an upwelling event are discussed.

Scarpace, F. L.

Interactive analysis of thermal imagery

Necessary knowledge is presented on data acquisition and preparation for analysis of thermal imagery of power plant heated discharges remotely sensed from an aircraft, with special emphasis on analog to digital conversion of analog tapes acquired during scanning and to geometrical scaling. The central element in the interactive analysis of thermal imagery is an interactive graphics computer terminal which allows an interpreter to effectively interact with a large-scale computer, providing decisions or data as computations are carried out. A temperature calibration is performed, which the interpreter may test anywhere on the image. When satisfied that calibration is correct, the portion of the image to be analyzed is outlined. Printed and microfiche analyses of the plume are produced. The flow chart of programs for analysis of thermal imagery is presented and discussed in some detail.

Madding, R. P.

Scanning thermal plumes

Over a three-year period 800 thermal line scans of power plant plumes were made by an airborne scanner, with ground truth measured concurrently at the plants. Computations using centered finite differences in the thermal scanning imagery show a lower bound in the horizontal temperature gradient in excess of 1.6 C/m. Gradients persist to 3 m below the surface. Vector plots of the velocity of thermal fronts are constructed by tracing the front motion in successive thermal images. A procedure is outlined for the two-point ground calibration of a thermal scanner from an equation describing the scanner signal and the voltage for two known temperatures. The modulation transfer function is then calculated by input of a thermal step function and application of digital time analysis techniques using Fast Fourier Transforms to the voltage output. Field calibration tests are discussed. Data accuracy is limited by the level of ground truth effort chosen.

Scarpace, F. L.

Scanning thermal plumes

In order to study the behavior and effects of thermal plumes associated with the condenser cooling of power plants, thermal line scans are periodically made from aircraft over all power plants along the Wisconsin shore of Lake Michigan. Simultaneous ground truth is also gathered with a radiometer. Some sequential imagery has been obtained for periods up to two hours to study short term variations in the surface temperature of the plume. The article concentrates on the techniques used to analyze thermal scanner data for a single power plant which was studied intensively. The calibration methods, temperature dependence of the thermal scanner, and calculation of the modulation transfer function for the scanner are treated. It is concluded that obtaining quantitative surface-temperature data from thermal scanning is a nontrivial task. Accuracies up to plus or minus 0.1 C are attainable.

Scarpace, F. L.