Engineering PapersSearch

Engineering topics

Ma, Zhiwen [National Renewable Energy Lab., Golden, CO (United States)] (ORCID:0000000337188038)

Publications and source records attributed to Ma, Zhiwen [National Renewable Energy Lab., Golden, CO (United States)] (ORCID:0000000337188038).

Development of a Digital Twin for Hydrogen Dispersion and Safety Assessment in an Electrolyzer Based Hydrogen Production Facility

Digital twin models are virtual representations of physical systems that use real-time data to simulate and optimize performance. This study presents the development and initial implementation of a digital twin (DT) for the electrolyzer-based hydrogen production facility at NREL's Advanced Research on Integrated Energy Systems (ARIES), focused on enhancing safety and optimizing sensor placement through physics-based simulations and metadata integration. The DT incorporates detailed facility-specific information, including component layout, leak locations, and controlled release parameters, to model hydrogen dispersion under varying environmental conditions. Using steady-state computational fluid dynamics (CFD) simulations informed by real meteorological data, such as wind speed, direction, and vertical wind profiles, the DT enables visualization of hydrogen plume behavior and spatial concentration distributions. Comparative analysis between high and low wind speed scenarios illustrates the significant influence of wind dynamics on plume shape and extent, with horizontal momentum dominating dispersion at higher speeds, while buoyancy effects become more prominent under low wind conditions. These simulations generate a rich dataset embedded within the DT, allowing users to assess potential leak outcomes and identify optimal sensor locations based on concentration thresholds. The model supports scenario-based analysis to guide safety strategies and equipment deployment for open-area hydrogen infrastructure. The digital twin thus serves as a dynamic platform for virtual prototyping, providing predictive insight into hydrogen behavior and enhancing risk-informed decision-making. This initial phase establishes a validated foundation for future integration of transient, uncontrolled leak scenarios and real-time sensor feedback, positioning the DT as a critical tool for safety design, operational planning, and adaptive monitoring in hydrogen systems. Overall, the approach demonstrates the value of combining environmental data with digital simulations to inform safer and more efficient deployment of hydrogen technologies.

08 HYDROGEN

Particle Handling in Particle-Based Pumped Thermal Energy Storage

A particle-based pumped thermal electricity storage system stores high-temperature heat (~1000 degrees C) in low-cost silica sand and generates power through an efficient power cycle. Central to this system is a counterflow direct-contact gas/particle fluidized-bed heat exchanger, which can significantly improve the heat exchange process due to the large heat transfer surface area of particles. To showcase a lab-scale 10- to 20-kWe heat exchange process with particles heating up to 300 degrees C, a comprehensive hydrodynamic analysis of the fluidization condition inside the heat exchanger was conducted. The heat exchanger was designed to target for heat exchange process of 10-20 kW and accommodate an air mass flow rate of 0.3-0.7 kg/s. The fluidization condition was set to maintain stable bubbling fluidization, thereby maximizing the particle-to-air heat transfer. An air distributor was designed to equally distribute air over the bed, which can avoid defluidized zones in the heat exchanger. Additionally, particle handling systems including L-valves, screw conveyors, and pneumatic conveyors were developed for the prototype heat exchanger, efficiently conveying high-temperature particles at 0.2-0.5 kg/s. This work lays the foundation for scaling up the system and integrating it into larger energy storage applications, demonstrating its potential for efficient, high-temperature thermal energy storage and power generation.

25 ENERGY STORAGE

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE