A planar-sheet nongraphitic zero-bandgap sp 2 carbon phase made by the low-temperature reaction of γ-graphyne

The highest sheet symmetry form of graphyne, with one triple bond between each neighboring hexagon in graphene, irreversibly transforms exothermically at ambient pressure and low temperatures into a nongraphitic, planar-sheet, zero-bandgap phase consisting of intrasheet-bonded sp 2 carbons. The synthesis of this sp 2 carbon phase is demonstrated, and other carbon phases are described for possible future synthesis from graphyne without breaking graphyne bonds. While measurements and theory indicate that the reacting graphyne becomes nonplanar because of sheet wrinkling produced by dimensional mismatch between reacted and nonreacted sheet regions, sheet planarity is regained when the reaction is complete. Although the observed elimination of triple bonds to make parallel planar sp 2 carbon sheets likely requires ordered transformation within each sheet, diffraction data for reacted multisheet stacks indicate that the relative lateral positions of neighboring sheets are disordered, as predicted, since no crystalline diffraction peak (other than for the intersheet spacing) is observed.

Aliev, Ali E. (ORCID:0000000300349707)↗

SELF-HEALING PNEUMATIC ACTUATOR DIAPHRAGMS

In the oil and gas industry, damaged diaphragms in pneumatic actuators can lead to unintended methane leaks, increasing emissions. In this work, replacement self-healing diaphragms are manufactured for a commercial pneumatic actuator. To enable self-healing, hollow microvascular networks are created within the diaphragms using sacrificial 3D printed PLA w/ tin(II) oxalate. These microvascular networks are filled with healing chemistries and, upon damage, rupture. After rupturing, the healing chemistries mix and cure to “heal” the damage and reduce leaks. Separate actuator test stands using nitrogen gas and using natural gas were developed to assess the healing performance of diaphragms. A fatigue stand was also developed to evaluate the effects of the different microvascular network geometries on the fatigue life of diaphragms. Our results demonstrate self-healing in diaphragms subjected to damage and tested for leaks. In fatigue testing, our results indicate that the introduction of microvascular networks does not influence the fatigue life.

Self-healing, pneumatic actuator↗