Engineering Papers⌕ Search

Engineering topics

Luiten, Andre N

Publications and source records attributed to Luiten, Andre N.

Testing Lorentz invariance using an odd-parity asymmetric optical resonator

We present the first experimental test of Lorentz invariance using the frequency difference between counter-propagating modes in an asymmetric odd-parity optical resonator. This type of test is {approx}10{sup 4} more sensitive to odd-parity and isotropic (scalar) violations of Lorentz invariance than equivalent conventional even-parity experiments due to the asymmetry of the optical resonator. The disadvantages of odd-parity resonators have been negated by the use of counter-propagating modes, delivering a high level of immunity to environmental fluctuations. With a nonrotating experiment our result limits the isotropic Lorentz violating parameter {kappa}-tilde{sub tr} to 3.4{+-}6.2x10{sup -9}, the best reported constraint from direct measurements. Using this technique the bounds on odd-parity and scalar violations of Lorentz invariance can be improved by many orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative atomic spectroscopy for primary thermometry

Quantitative spectroscopy has been used to measure accurately the Doppler broadening of atomic transitions in {sup 85}Rb vapor. By using a conventional platinum resistance thermometer and the Doppler thermometry technique, we were able to determine k{sub B} with a relative uncertainty of 4.1x10{sup -4} and with a deviation of 2.7x10{sup -4} from the expected value. Our experiment, using an effusive vapor, departs significantly from other Doppler-broadened thermometry (DBT) techniques, which rely on weakly absorbing molecules in a diffusive regime. In these circumstances, very different systematic effects such as magnetic sensitivity and optical pumping are dominant. Using the model developed recently by Stace and Luiten, we estimate the perturbation due to optical pumping of the measured k{sub B} value was less than 4x10{sup -6}. The effects of optical pumping on atomic and molecular DBT experiments is mapped over a wide range of beam size and saturation intensity, indicating possible avenues for improvement. We also compare the line-broadening mechanisms, windows of operation and detection limits of some recent DBT experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Colloquium: Comparison of astrophysical and terrestrial frequency standards

The stability of pulse arrival times from pulsars and white dwarfs have been reanalyzed using several analysis tools for measuring the noise characteristics of sampled time and frequency data. The best terrestrial artificial clocks are shown to substantially exceed the performance of astronomical sources as timekeepers in terms of accuracy (as defined by cesium primary frequency standards) and stability. This superiority in stability can be directly demonstrated over time periods up to 2 years, where there is high quality data for both. Beyond 2 years there is a deficiency of data for clock-to-clock comparisons, and both terrestrial and astronomical clocks show equal performance being equally limited by the quality of the reference time scales used to make the comparisons. Nonetheless, the detailed accuracy evaluations of modern terrestrial clocks imply that these new clocks are likely to have a stability better than any astronomical source up to comparison times of at least hundreds of years. This article is intended to provide a correct appreciation of the relative merits of natural and artificial clocks. The use of natural clocks as tests of physics under the most extreme conditions is entirely appropriate; however, the contention that these natural clocks, particularly white dwarfs, can compete as timekeepers against devices constructed by mankind is shown to be doubtful.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fractional frequency instability in the 10{sup -14} range with a thermal beam optical frequency reference

We demonstrate a means of increasing the signal-to-noise ratio in a Ramsey-Borde interferometer with spatially separated oscillatory fields on a thermal atomic beam. The {sup 1}S{sub 0}{r_reversible}{sup 3}P{sub 1} intercombination line in neutral {sup 40}Ca is used as a frequency discriminator, with an extended cavity diode laser at 423 nm probing the ground state population after a Ramsey-Borde sequence of 657 nm light-field interactions with the atoms. Evaluation of the instability of the Ca frequency reference is carried out by comparison with (i) a hydrogen-maser and (ii) a cryogenic sapphire oscillator. In the latter case the Ca reference exhibits a square-root {Lambda} variance of 9.2x10{sup -14} at 1 s and 2.0x10{sup -14} at 64 s. This is an order-of-magnitude improvement for optical beam frequency references, to our knowledge. The shot noise of the readout fluorescence produces a limiting square-root {Lambda} variance of 7x10{sup -14}/{radical}({tau}), highlighting the potential for improvement. This work demonstrates the feasibility of a portable frequency reference in the optical domain with 10{sup -14} range frequency instability.

74 ATOMIC AND MOLECULAR PHYSICS↗