Engineering PapersSearch

Engineering topics

Luecke, William E.

Publications and source records attributed to Luecke, William E..

Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

Luecke, William E.

Neutron Diffraction Study Oxygen Dissolution Alpha(sub 2)-Ti3Al

Rietveld refinements of neutron powder diffraction data on alpha(sub 2)-Ti3Al have been performed to determine the crystal structure as a function of interstitial oxygen (O) concentration for three alloys with a Ti/Al ratio of approximately equal to 2.34 and O concentrations of 0.25%, 3.99% and 7.71%. The structures of the allows are hexagonal in space group P6(sub 3)/mmc where Ti and Al atoms populate unique sites with excess Al at the Ti site and O atoms occupy octahedral interstitial sites surrounded by six Ti sites. The length of the c-axis was found to increase linearly as the O occupancy of the interstitial sites increased; this lattice lengthening effect was much less pronounced along the alpha axis. Correspondingly, the increases in the lengths of Ti-Al and Ti-Ti bonds with a major component of their direction parallel to the c-axis were roughly an order of magnitude greater than the increases in the lengths of Ti-al and Ti-Ti bonds more closely aligned with the alpha-axis. Densities calculated form the lattice parameters and occupancy factors fall in the range (4.118 plus or minus 0.004) grams per cubic centimeter to (4.194 plus or minus 0.004) grams per cubic centimeter, and exhibit a nearly linear increase with oxygen concentration. Measured densities of (4.113 plus or minus 0.001) grams per cubic centimeter, (4.146 plus or minus 0.009) grams per cubic centimeter, and (4.191 plus or minus 0.002) grams per cubic centimeter for these alloys agree with the results of the refinements.

Jones, Camille Y.