Cavitation characteristics of a small centrifugal pump in He I and He II
The cavitation characteristics of a small preinduced centrifugal pump operating in He I and He II over the temperature range 1.8-4.2 K are presented. The pump and close-coupled induction motor operate immersed in liquid helium. A six-blade propeller inducer and a three-blade screw inducer were both tested. With this pump configuration using either inducer, there is a tremendous difference between the cavitation characteristics of He I and He II. The net positive suction head requirements for this pump with the screw inducer could not be determined for He I, but it is less than -100 mm and, depending on flow rate, ranges between 35 and 165 mm for He II.