Engineering Papers⌕ Search

Engineering topics

Lu, Wei

Publications and source records attributed to Lu, Wei.

At least 541 records · Page 30

Quality of epitaxial InAs nanowires controlled by catalyst size in molecular beam epitaxy

In this study, the structural quality of Au-catalyzed InAs nanowires grown by molecular beam epitaxy is investigated. Through detailed electron microscopy characterizations and analysis of binary Au-In phase diagram, it is found that defect-free InAs nanowires can be induced by smaller catalysts with a high In concentration, while comparatively larger catalysts containing less In induce defected InAs nanowires. This study indicates that the structural quality of InAs nanowires can be controlled by the size of Au catalysts when other growth conditions remain as constants.

36 MATERIALS SCIENCE↗

The resonant tunability, enhancement, and damping of plasma waves in the two-dimensional electron gas plasmonic crystals at terahertz frequencies

The ability to manipulate plasma waves in the two-dimensional-(2D)-electron-gas based plasmonic crystals is investigated in this work. It is demonstrated that the plasmon resonance of 2D plasmonic crystal can be tuned easily at terahertz frequency due to the wavevector quantization induced by the size effect. After calculating self-consistently by taking into account several potential mechanisms for the resonant damping of plasma waves, it can be concluded that the plasmon-plasmon scattering plays the dominant role. Based on the calculations, we can predict the scattering or inter-excitation among the oblique plasmons in the 2D crystal. The results can be extended to study 2D-electron-gas plasmonic waveguides, terahertz modulators, and detectors with electrostatic gating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial-Temporal [{sup 18}F]FDG-PET Features for Predicting Pathologic Response of Esophageal Cancer to Neoadjuvant Chemoradiation Therapy

Purpose: To extract and study comprehensive spatial-temporal {sup 18}F-labeled fluorodeoxyglucose ([{sup 18}F]FDG) positron emission tomography (PET) features for the prediction of pathologic tumor response to neoadjuvant chemoradiation therapy (CRT) in esophageal cancer. Methods and Materials: Twenty patients with esophageal cancer were treated with trimodal therapy (CRT plus surgery) and underwent [{sup 18}F]FDG-PET/CT scans both before (pre-CRT) and after (post-CRT) CRT. The 2 scans were rigidly registered. A tumor volume was semiautomatically delineated using a threshold standardized uptake value (SUV) of ≥2.5, followed by manual editing. Comprehensive features were extracted to characterize SUV intensity distribution, spatial patterns (texture), tumor geometry, and associated changes resulting from CRT. The usefulness of each feature in predicting pathologic tumor response to CRT was evaluated using the area under the receiver operating characteristic curve (AUC) value. Results: The best traditional response measure was decline in maximum SUV (SUV{sub max}; AUC, 0.76). Two new intensity features, decline in mean SUV (SUV{sub mean}) and skewness, and 3 texture features (inertia, correlation, and cluster prominence) were found to be significant predictors with AUC values ≥0.76. According to these features, a tumor was more likely to be a responder when the SUV{sub mean} decline was larger, when there were relatively fewer voxels with higher SUV values pre-CRT, or when [{sup 18}F]FDG uptake post-CRT was relatively homogeneous. All of the most accurate predictive features were extracted from the entire tumor rather than from the most active part of the tumor. For SUV intensity features and tumor size features, changes were more predictive than pre- or post-CRT assessment alone. Conclusion: Spatial-temporal [{sup 18}F]FDG-PET features were found to be useful predictors of pathologic tumor response to neoadjuvant CRT in esophageal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Au impact on GaAs epitaxial growth on GaAs (111){sub B} substrates in molecular beam epitaxy

GaAs growth behaviour under the presence of Au nanoparticles on GaAs {l_brace}111{r_brace}{sub B} substrate is investigated using electron microscopy. It has been found that, during annealing, enhanced Ga surface diffusion towards Au nanoparticles leads to the GaAs epitaxial growth into {l_brace}113{r_brace}{sub B} faceted triangular pyramids under Au nanoparticles, governed by the thermodynamic growth, while during conventional GaAs growth, growth kinetics dominates, resulting in the flatted triangular pyramids at high temperature and the epitaxial nanowires growth at relatively low temperature. This study provides an insight of Au nanoparticle impact on GaAs growth, which is critical for understanding the formation mechanisms of semiconductor nanowires.

36 MATERIALS SCIENCE↗

Nanostructure Patterning Under Energetic Particle Beam Irradiation

Energetic ion bombardment can lead to the development of complex and diverse nanostructures on or beneath the material surface through induced self-organization processes. These self-organized structures have received particular interest recently as promising candidates as simple, inexpensive, and large area patterns, whose optical, electronic and magnetic properties are different from those in the bulk materials. Compared to the low mass efficiency production rate of lithographic methods, these self-organized approaches display new routes for the fabrication of nanostructures over large areas in a short processing time at the nanoscale, beyond the limits of lithography. Although it is believed that surface nanostructure formation is based on the morphological instability of the sputtered surface, driven by a kinetic balance between roughening and smoothing actions, the fundamental mechanisms and experimental conditions for the formation of these nanostructures has still not been well established, the formation of the 3-D naopatterns beneath the irradiated surface especially needs more exploration.

42 ENGINEERING↗

NOBLE GAS PRODUCTION FROM MERCURY SPALLATION AT SNS

Calculations for predicting the distribution of the products of spallation reactions between high energy protons and target materials are well developed and are used for design and operational applications in many projects both within DOE and in other arenas. These calculations are based on theory and limited experimental data that verifies rates of production of some spallation products exist. At the Spallation Neutron Source, a helium stream from the mercury target flows through a system to remove radioactivity from this mercury target offgas. The operation of this system offers a window through which the production of noble gases from mercury spallation by protons may be observed. This paper describes studies designed to measure the production rates of twelve noble gas isotopes within the Spallation Neutron Source mercury target.

DeVore, Joe R↗

Improved Moderator Performance Calculations at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory reached a nominal operating power of 1 MW in September, 2009. Even at ~2/3 of its designed capacity, SNS already becomes the brightest pulsed neutron source in the world, and a premier facility for material and life science research. To provide accurate target performance estimation and to meet future development needs, we had developed an as-built model for the operating target system of SNS. Based on this asbuilt model, the moderator performance at SNS was recalculated taking advantage of the improved physics and tallying method in the Monte Carlo simulation code, MCNPX, and most recent scattering kernels. The neutron flux intensity spectra, emission time distributions of neutron pulses and moderator brightness profiles regarding the SNS moderator performance are presented and discussed. Compared to the previous results, the current calculations show ~10-20% lower in flux with improved emission time distributions of neutron pulses. The difference between the two data sets is analyzed, as well as other factors impacting the moderator performance at SNS. The current calculation results will serve as source terms for the instrument performance simulations at SNS.

Lu, Wei↗

Comparison of 16-Channel Laser Photoreceivers for Topographic Mapping

Topographic mapping lidar instruments must be able to detect extremely weak laser return signals from high altitudes including orbital distance. The signals have a wide dynamic range caused by the variability in atmospheric transmission and surface reflectance under a fast moving spacecraft. Ideally, lidar detectors should be able to detect laser signal return pulses at the single photon level and produce linear output for multiple photon events. Silicon avalanche photodiode (APO) detectors have been used in most space lidar receivers to date. Their sensitivity is typically hundreds of photons per pulse, and is limited by the quantum efficiency, APO gain noise, dark current, and preamplifier noise. NASA is pursuing three approaches for a 16-channel laser photoreceiver for use on the next generation direct-detection airborne and spacebome lidars. We present our measurement results and a comparison of their performance.

Krainak, Michael A.↗

Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating

Purpose: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. Methods: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. Results: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. Conclusions: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06{+-}0.02 s at peak inhalation and 0.05{+-}0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SNS second target station moderator performance update

In its first years of operations of its first target station, the Spallation Neutron Source (SNS) is working towards a facility upgrade by a megawatt-class second target station operated at 20 Hz repetition rate, which is intended to complement the existing ORNL neutron sources, the first SNS target station and the HFIR reactor, with high-intensity cold neutron beams.The first round of optimization calculations converged on larger-volume cylindrical para-hydrogen moderators placed in wing configuration on top and bottom of a flat mercury target, pre-moderated by layers of ambient water and surrounded by beryllium reflector. The metric of these optimization calculations was time-averaged and energy-integrated neutron brightness below 5 meV with the requirement to be able to serve 20 ports with neutrons. A summary of these calculations will be given including lessons learned from the variety of simulated configurations and detailed neutron performance characteristics like spectral intensities, emission time distributions, local variations of moderator brightness at the viewed areas, and sensitivity of the optimization metric to optimized parameters for the most promising configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗