Engineering PapersSearch

Engineering topics

Lowrance, J. L.

Publications and source records attributed to Lowrance, J. L..

Evaluation of selected detector arrays for space applications

The development of a high density Schottky barrier Infrared Charged Coupled Device (IRCCD) type image sensor for earth observation was initiated. A dual band 512 pixel linear array was developed, which was capable of being butted end to end to make an arbitrarily long linear array. Measurement made on palladium silicide IRCCDs that were two-dimensional 63 x 32 pixel arrays were summarized. The test data on a 512 pixel linear array is also summarized.

Lowrance, J. L.

Evaluation of RCA thinned buried channel charge-coupled devices /CCDs/ for scientific applications

An experimental version of a thinned illuminated buried-channel 512 x 320 pixel CCD with reduced amplifier input capacitance has been produced which is characterized by lower readout noise. Changes made to the amplifier are discussed, and readout noise measurements obtained by several different techniques are presented. The single energetic electron response of the CCD in the electron-bombarded mode and the single 5.9 keV X-ray pulse height distribution are reported. Results are also given on the dark current versus temperature and the spatial frequency response as a function of signal level.

Zucchino, P.

Echelle spectroscopy with a charge-coupled device /CCD/

The recent availability of large format CCD's with high quantum efficiency makes it possible to achieve significant advances in high dispersion astronomical spectroscopy. An echelle CCD combination excels or equals other techniques presently available, and offers the advantage of complete spectral coverage of several thousand Angstroms in a single exposure. Attention is given to experiments which were conducted with a CCD camera head and an echelle spectrograph on a 4-meter telescope. It was found possible to achieve a signal-to-noise ratio of 150/1 on a 13th magnitude star at 6000 A in a two-hour exposure at 0.16 A/pixel, limited primarily by photon statistics. For fainter objects, readout noise is the limiting factor in precision. For 20 electron rms readout noise, an S/N = 15/1 at 18th magnitude is expected, all other things being equal.

York, D. G.

Electron bombardment charge-coupled device /CCD/ detectors for the vacuum ultraviolet

Development work is underway at Princeton and NRL on electronic-readout imaging detectors for the VUV which are based on electron-bombardment CCD arrays and opaque alkali-halide photocathodes. These detectors provide single-photoelectron detection capability and wide dynamic range combined with almost the maximum possible quantum efficiency (in excess of 50% in the wavelength range below 1300 A). The Princeton work is based on an oblique-focusing electron optical configuration, while the NRL program is based on a Schmidt optical system with opaque photocathode. Results of preliminary tests at Princeton and overall system concepts for the Princeton and NRL cameras are discussed, and applications to possible space astronomy studies are examined.

Lowrance, J. L.

TV system considerations for the Space Telescope

The Space Telescope, designed as a permanent observatory in space, will be launched into orbit, maintained, and refurbished by the Space Shuttle. One of the primary instruments to fly with the telescope is the f/24 Camera. The camera's mission requirements and their impact on the choice and design of a television system are discussed, along with the system engineering aspects of the TV system design and spacecraft design. An SEC type television camera tube was selected as the primary data acquisition sensor, because of its ability to accommodate exposure times of several hours with only modest cooling.

Lowrance, J. L.

Large format SEC orthicon integrating television sensor for LST

The Large Space Telescope will employ a 70 mm format SEC type television camera tube as the data sensor for one or more scientific instruments. The characteristics of this tube are described. The current performance is characterized by an MTF of 50% at 20 line pairs per mm and a signal-to-noise ratio that is about one-half the theoretical based on the square root of the number of photoelectrons. The paper presents some astronomical results and the status of the environmental testing of the tube. Other topics such as radiation sensitivity and thermal design are also discussed.

Lowrance, J. L.

Soft X-ray detection with the Fairchild 100 by 100 CCD

The soft X-ray sensitivity of the Fairchild 100 x 100 element CCD is studied for possible use as a detector in plasma physics research. The experimental setup and laboratory results are reported including data on slow scan operation of the CCD and performance when cooled. Results from digital computer processing of the data to correct for element-to-element nonuniformities are also discussed.

Renda, G.

Study of Permanent Magnet Focusing for Astronomical Camera Tubes

A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

Long, D. C.

Large space telescope television sensor development

Studies conducted towards the development of space astronomy television sensors are reported. The SEC vidicon tubes being utilized in the development effort are described. The operational characteristics of these tubes are given in tables and charts together with discussions of their significance.

Lowrance, J. L.

The spectrum of the quasi-stellar object PHL 957.

Spectra of the radio-quiet quasar PHL 957 were obtained at a 200-in. telescope with a Cassegrain image tube, a Cassegrain multichannel spectrometer, and an integrating television camera on the spectrograph. The image-tube spectra revealed 64 absorption lines between 3200 and 6800 A. The absolute energy distribution indicates that this quasar is one of the most luminous known. The absorption line redshifts and line profiles observed are discussed.

Lowrance, J. L.

Recent developments and applications of the SEC vidicon for astronomy

The engineering development of the SEC vidicon as an astronomical sensor has continued in parallel with its operational use. One scientific application was the six hour exposure of the quasar PHL-957 at the Coude spectrograph of the 200-inch Hale telescope. The developmental effort includes both the enhancement of the basic attributes that make the SEC an appropriate sensor, namely, high quantum efficiency, low threshold, and long integration; as well as work to broaden its scientific usefulness, such as the development of a MgF2 photocathode window for vacuum ultraviolet sensitivity, and a permanent magnet focus design for thermal compatibility with proposed large space telescopes. Additional details on the characteristics of the SEC tube are discussed, as well as plans to make a larger and higher resolution version.

Zucchino, P.

Development of television tubes for the large space telescope

Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. The performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode is discussed. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope 2 for direct high resolution imagery is also discussed. The paper also discusses the large space telescope image sensor requirements and the development of a larger television tube for this mission.

Lowrance, J. L.

Development of television tubes for the large space telescope.

Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. This paper discusses the performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope II for direct high resolution imagery is also discussed. The paper also discusses the Large Space Telescope image sensor requirements and the development of a larger television tube for this mission.

Lowrance, J. L.