Engineering Papers⌕ Search

Engineering topics

Long, J.

Publications and source records attributed to Long, J..

Precision half-life determination for the β + emitter N 13

A new precision half-life measurement of 13 N has been conducted using the TwinSol β-counting station at the University of Notre Dame. Here, the measured value of $t^{new}_{1/2}$ = 597.05(19) s differs from the previous world value by about 2.8σ. An evaluation of the 13N half-life results in a $t^{world}_{1/2}$ = 597.19(22) s. Updated Standard Model predictions for the Fermi to Gamow-Teller mixing ratio ρ and its associated correlation parameters have been calculated using the new 13 N world half life in preparation for a future measurement of the mixing ratio. Finally, an ab initio no-core configuration interaction (NCCI) calculation for the B(GT) of this decay, carried out using the Daejeon16 interaction, has been carried out, revealing the need for higher-order chiral corrections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Merged-Element Transmon

Transmon qubits are ubiquitous in the pursuit of quantum computing using superconducting circuits. However, they have some drawbacks that still need to be addressed. Most importantly, the scalability of transmons is limited by the large device footprint needed to reduce the participation of the lossy capacitive parts of the circuit. In this work, we investigate and evaluate losses in an alternative device geometry, namely, the merged-element transmon (mergemon). To this end, we replace the large external shunt capacitor of a traditional transmon with the intrinsic capacitance of a Josephson junction and achieve an approximately 100 times reduction in qubit dimensions. We report the implementation of the mergemon using a sputtered Nb–amorphous-Si–Nb trilayer film. In an experiment below 10 mK, the frequency of the readout resonator, capacitively coupled to the mergemon, exhibits a qubit-state-dependent shift in the low-power regime. The device also demonstrates the single-photon and multiphoton transitions that represent a weakly anharmonic system in two-tone spectroscopy. The transition spectra are explained well with master-equation simulations. Here, a participation-ratio analysis identifies the dielectric loss of the amorphous-Si tunnel barrier and its interfaces as the dominant source for qubit relaxation. We expect the mergemon to achieve high coherence for relatively small device dimensions when implemented with a low-loss, epitaxially grown, and lattice-matched trilayer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intensity of a weak 519-keV γ ray following β decay of the superallowed emitter 34 Ar determined via the 33 S(p,γ) 34 Cl reaction

The predominant branch in the β decay of 34 Ar is the superallowed 0 + → 0 + transition to the ground state of 34 Cl. To determine its important branching ratio one must first establish the ratios for the competing Gamow-Teller branches based on the measured intensities of γ rays subsequently emitted from the excited states they populate in 34 Cl. The strongest of these branches populates the 1 + state at 666 keV in 34 Cl, which has three possible γ-decay paths. Here, we report here a measurement of the decay of this state, which we populated via resonant proton capture in the reaction 33 S(p,γ) 34 Cl. We find that the intensity of the 519-keV γ-ray path is 1.46(19)% relative to that of the 666-keV path. This result is critical to new precise measurements of the superallowed decay of 34 Ar.

20 ≤ A ≤ 38↗

A new cryogenic apparatus to search for the neutron electric dipole moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). This apparatus uses superfluid 4 He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized 3 He from an Atomic Beam Source injected into the superfluid 4 He and transported to the measurement cells where it serves as a co-magnetometer. The superfluid 4 He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. Finally, these features provide an ultimate statistical uncertainty for the EDM of 2-3× 10 -28 e-cm, with anticipated systematic uncertainties below this level.

47 OTHER INSTRUMENTATION↗

Solid state streak camera prototype performance testing and future upgrades

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolving diagnostics for studying events that occur on the nanosecond to microsecond time scales. The Nevada National Security Site (NNSS) and Sandia National Laboratories (SNL) have built a 42-channel solid state streak camera (SSSC) prototype as a proof of concept for use as a streak camera replacement. This work is part of an ongoing project to develop the technology to a level competitive with analog streak cameras. This manuscript discusses the device concept, results from electronic and laser testing, and recent improvements to increase the device’s dynamic range.

Plasma diagnostics - interferometry, spectroscopy ↗

Gamma rays of 0.3-30 MeV from PSR0833 - 45

Pulsed gamma rays from the Vela pulsar PSR0833 - 45 are reported for the first time over the medium energy range 0.3-30 MeV. They were observed with a double scatter gamma-ray telescope flown on a balloon over Australia on Nov. 10, 1981, 31 days after a large glitch in the pulsar period. The first and second pulses were detected from single scatters in the top scintillators at energies over 0.3 MeV with statistical significances of 1.6 sigma each, and by double scatters from all detector cell pairs at energies of 1-30 MeV with significance of 4.8 sigma and 3.8 sigma. The phase separation of the two pulses is 0.43 + or - 0.02 at the same absolute phases previously found by SAS2 and COS B for energies over 35 MeV.

Tumer, O. T.↗

Gamma rays of 1-30 MeV from the Vela Pulsar PSR 0833-45

Results are reported for observations of gamma rays of 1-30 MeV from the Vela Pulsar PSR 0833 - 45 carried out with the UCR double scatter gamma ray telescope on a balloon launched from Alice Springs, Australia on November 10, 1981. An integrated flux of (5.3 + or - 1.3) x 10 to the -4th photons/sq cm/s is found for the Vela region above 2 MeV. This value, together with those for the energy intervals of 2-4, 4-7, and 7-15 MeV are in reasonable agreement with the power law found by COS-B at energies above 50 MeV. A sky contour map of the fluxes is shown.

Tumer, T.↗

Gamma rays of 1-30 MeV from the Galactic Center Region

Preliminary results are reported for gamma rays from the Galactic Center Region at 1-30 MeV made with a balloon-borne double Compton scatter gamma ray telescope. The Compton scatter angle, energy, and arrival time of the incident gamma ray and direction of the Compton scattered secondary for downward-moving gamma rays were measured. The handling of the data is described, and the results of Monte Carlo simulation angular resolutions and absolute efficiencies for different zenith angles of incident gamma rays are given. A contour sky map of the weighted fluxes for a southern sky region is shown whose primary feature is a significant enhancement in the Galactic Center Region. It is concluded that several discrete sources contribute to broaden the maximum in the horizontal or RA direction. Less broadening is indicated along the galactic plane.

Oneill, T.↗

Cross correlation analysis of medium energy gamma rays for the Northern Hemisphere

In the cross correlation method the observed gamma rays are compared with the expected telescope response for a discrete celestial source. The background consists of the atmospheric flux with its maximum near the horizon, the cosmic diffuse flux, and neutron induced gamma rays in the telescope. In sharp contrast to the background, a celestial source produces an asymmetric azimuthal response which varies predictably in time as the source moves through the telescope's aperture. This contrast serves as the basis of the cross correlation technique. Continuous data of 47.5 hr were obtained during a balloon flight from Palestine, TX from 0930 UT on September 30, 1978 to 2300 UT on October 1, 1978. The Crab Nebula-Anticenter region was observed on two consecutive days. A number of other medium energy source candidates also crossed the field-of-view. The obtained results are discussed.

Long, J.↗

Double Compton scatter telescope calibration

Calibration techniques for a medium energy gamma ray telescope are described. Gain calibration using Compton edge spectra involves comparisons of pulse height spectra with spectra simulated by a Monte Carlo computer code which includes Compton scattering and pair production, plural scattering and variable energy resolution, and cell size. The telescope considered comprises 56 cells of liquid scintillator in four size groups, with a total liquid volume of 325 l; each cell has its own photomultiplier tube. Energy and angular resolutions and the PMT gain calibration procedure are verified with double scatter data for monoenergetic gamma rays at a known location. Detection probabilities for any cell combination in the two telescope arrays are calculated per steradian as a function of the scattering for a number of different energies with a Van de Graaff accelerator.

Dayton, B.↗

Streak camera time calibration procedures

Time calibration procedures for streak cameras utilizing a modulated laser beam are described. The time calibration determines a writing rate accuracy of 0.15% with a rotating mirror camera and 0.3% with an image converter camera.

Long, J.↗