8-9 and 14-15 mue Two-Color 640X486 AAS/AIGaAs Quantum Well Infrared Photodetector (QWIP) Focal Plane Array Camera
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Long, J..
Explore the source record for details and available documents.
An optimized long-wavelength two-color Quantum Well Infrared Phototdetector (QWIP) device structure has been designed. This device structure was grown on a three-inch semi-insulating GaAs substrate by molecular beam epitaxy (MBE).
An optimized long-wavelength very long-wavelength two-color Quantum Well Infrared Photodetector (QWIP) device structure has been designed.
Pulsed gamma rays from the Vela pulsar PSR0833 - 45 are reported for the first time over the medium energy range 0.3-30 MeV. They were observed with a double scatter gamma-ray telescope flown on a balloon over Australia on Nov. 10, 1981, 31 days after a large glitch in the pulsar period. The first and second pulses were detected from single scatters in the top scintillators at energies over 0.3 MeV with statistical significances of 1.6 sigma each, and by double scatters from all detector cell pairs at energies of 1-30 MeV with significance of 4.8 sigma and 3.8 sigma. The phase separation of the two pulses is 0.43 + or - 0.02 at the same absolute phases previously found by SAS2 and COS B for energies over 35 MeV.
Results are reported for observations of gamma rays of 1-30 MeV from the Vela Pulsar PSR 0833 - 45 carried out with the UCR double scatter gamma ray telescope on a balloon launched from Alice Springs, Australia on November 10, 1981. An integrated flux of (5.3 + or - 1.3) x 10 to the -4th photons/sq cm/s is found for the Vela region above 2 MeV. This value, together with those for the energy intervals of 2-4, 4-7, and 7-15 MeV are in reasonable agreement with the power law found by COS-B at energies above 50 MeV. A sky contour map of the fluxes is shown.
Preliminary results are reported for gamma rays from the Galactic Center Region at 1-30 MeV made with a balloon-borne double Compton scatter gamma ray telescope. The Compton scatter angle, energy, and arrival time of the incident gamma ray and direction of the Compton scattered secondary for downward-moving gamma rays were measured. The handling of the data is described, and the results of Monte Carlo simulation angular resolutions and absolute efficiencies for different zenith angles of incident gamma rays are given. A contour sky map of the weighted fluxes for a southern sky region is shown whose primary feature is a significant enhancement in the Galactic Center Region. It is concluded that several discrete sources contribute to broaden the maximum in the horizontal or RA direction. Less broadening is indicated along the galactic plane.
In the cross correlation method the observed gamma rays are compared with the expected telescope response for a discrete celestial source. The background consists of the atmospheric flux with its maximum near the horizon, the cosmic diffuse flux, and neutron induced gamma rays in the telescope. In sharp contrast to the background, a celestial source produces an asymmetric azimuthal response which varies predictably in time as the source moves through the telescope's aperture. This contrast serves as the basis of the cross correlation technique. Continuous data of 47.5 hr were obtained during a balloon flight from Palestine, TX from 0930 UT on September 30, 1978 to 2300 UT on October 1, 1978. The Crab Nebula-Anticenter region was observed on two consecutive days. A number of other medium energy source candidates also crossed the field-of-view. The obtained results are discussed.
Calibration techniques for a medium energy gamma ray telescope are described. Gain calibration using Compton edge spectra involves comparisons of pulse height spectra with spectra simulated by a Monte Carlo computer code which includes Compton scattering and pair production, plural scattering and variable energy resolution, and cell size. The telescope considered comprises 56 cells of liquid scintillator in four size groups, with a total liquid volume of 325 l; each cell has its own photomultiplier tube. Energy and angular resolutions and the PMT gain calibration procedure are verified with double scatter data for monoenergetic gamma rays at a known location. Detection probabilities for any cell combination in the two telescope arrays are calculated per steradian as a function of the scattering for a number of different energies with a Van de Graaff accelerator.
Time calibration procedures for streak cameras utilizing a modulated laser beam are described. The time calibration determines a writing rate accuracy of 0.15% with a rotating mirror camera and 0.3% with an image converter camera.