Engineering Papers⌕ Search

Engineering topics

Loer, B.

Publications and source records attributed to Loer, B..

44 records · Page 3

DarkSide search for dark matter

The DarkSide staged program utilizes a two-phase time projection chamber (TPC) with liquid argon as the target material for the scattering of dark matter particles. Efficient background reduction is achieved using low radioactivity underground argon as well as several experimental handles such as pulse shape, ratio of ionization over scintillation signal, 3D event reconstruction, and active neutron and muon vetos. The DarkSide-10 prototype detector has proven high scintillation light yield, which is a particularly important parameter as it sets the energy threshold for the pulse shape discrimination technique. The DarkSide-50 detector system, currently in commissioning phase at the Gran Sasso Underground Laboratory, will reach a sensitivity to dark matter spin-independent scattering cross section of 10 -45 cm 2 within 3 years of operation.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches

The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Furthermore, surface event rejection capabilities were tested with two 210 Pb sources producing ~130 beta decays/hr. We found that in ~800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 x 10 -5 at 90% C.L., corresponding to<0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light yield in DarkSide-10: A prototype two-phase argon TPC for dark matter searches

As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS

We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) \mu s and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Purification of Argon from a Diluted Stream

We report on the design, performance and commissioning of a cryogenic distillation column for low radioactivity underground argon purification that has been constructed at Fermi National Accelerator Laboratory. The plant accepts a mixture of argon, helium, and nitrogen with low argon concentration and is designed to return pure argon with a nitrogen contamination less than 10 ppm. During the commissioning, the distillation column in a continuous mode produced argon 99.9% pure. After running in batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The argon production rate was about 1 kg/day.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Commissioning of a Cryogenic Distillation Column for Low Radioactivity Underground Argon

We report on the performance and commissioning of a cryogenic distillation column for low radioactivity underground argon at Fermi National Accelerator Laboratory. The distillation column is designed to accept a mixture of argon, helium, and nitrogen and return pure argon with a nitrogen contamination less than 10 ppm. In the first commissioning, we were able to run the distillation column in a continuous mode and produce argon that is 99.9% pure. After running in a batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The efficiency of collecting the argon from the gas mixture was between 70% and 81%, at an argon production rate of 0.84-0.98 kg/day.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Depleted Argon from Underground Sources

Argon is a strong scintillator and an ideal target for Dark Matter detection; however {sup 39}Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in {sup 39}Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO{sub 2} well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO{sub 2}. We first concentrate the argon locally to 3% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation, and then the N{sub 2} and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO{sub 2} facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗