Engineering Papers⌕ Search

Engineering topics

Lizarazo, J

Publications and source records attributed to Lizarazo, J.

Warm Magnetic Field Measurements of LARP HQ Magnet

The US-LHC Accelerator Research Program is developing and testing a high-gradient quadrupole (HQ) magnet, aiming at demonstrating the feasibility of Nb{sub 3}Sn technologies for the LHC luminosity upgrade. The 1 m long HQ magnet has a 120 mm bore with a conductor-limited gradient of 219 T/m at 1.9 K and a peak field of 15 T. HQ includes accelerator features such as alignment and field quality. Here we present the magnetic measurement results obtained at LBNL with a constant current of 30 A. A 100 mm long circuit-board rotating coil developed by FNAL was used and the induced voltage and flux increment were acquired. The measured b{sub 6} ranges from 0.3 to 0.5 units in the magnet straight section at a reference radius of 21.55 mm. The data reduced from the numerical integration of the raw voltage agree with those from the fast digital integrators.

43 PARTICLE ACCELERATORS↗

ASSEMBLY AND TEST OF A 120 MM BORE 15 T NB3SN QUADRUPOLE FOR THE LHC UPGRADE

In support of the Large Hadron Collider (LHC) luminosity upgrade, the US LHC Accelerator Research Program (LARP) has been developing a 1-meter long, 120 mm bore Nb{sub 3}Sn IR quadrupole magnet (HQ). With a design short sample gradient of 219 T/m at 1.9 K and a peak field approaching 15 T, one of the main challenges of this magnet is to provide appropriate mechanical support to the coils. Compared to the previous LARP Technology Quadrupole and Long Quadrupole magnets, the purpose of HQ is also to demonstrate accelerator quality features such as alignment and cooling. So far, 8 HQ coils have been fabricated and 4 of them have been assembled and tested in HQ01a. This paper presents the mechanical assembly and test results of HQ01a.

43 PARTICLE ACCELERATORS↗

A Superconducting transformer system for high current cable testing

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

43 PARTICLE ACCELERATORS↗

Analysis of Voltage Signals from Superconducting Accelerator Magnets

We present two techniques used in the analysis of voltage tap data collected during recent tests of superconducting magnets developed by the Superconducting Magnet Program at Lawrence Berkeley National Laboratory. The first technique was used on a quadrupole to provide information about quench origins that could not be obtained using the time-of-flight method. The second technique illustrates the use of data from transient flux imbalances occurring during magnet ramping to diagnose changes in the current-temperature margin of a superconducting cable. In both cases, the results of this analysis contributed to make improvements on subsequent magnets.

43 PARTICLE ACCELERATORS↗

Recent Test Results of the High Field Nb3Sn Dipole Magnet HD2

The 1 m long Nb{sub 3}Sn dipole magnet HD2, fabricated and tested at Lawrence Berkeley National Laboratory, represents a step towards the development of block-type accelerator quality magnets operating in the range of 13-15 T. The magnet design features two coil modules composed of two layers wound around a titanium-alloy pole. The layer 1 pole includes a round cutout to provide room for a bore tube with a clear aperture of 36 mm. After a first series of tests where HD2 reached a maximum bore field of 13.8 T, corresponding to an estimated peak field on the conductor of 14.5 T, the magnet was disassembled and reloaded without the bore tube and with a clear aperture increased to 43 mm. We describe in this paper the magnet training observed in two consecutive tests after the removal of the bore tube, with a comparison of the quench performance with respect to the previous tests. An analysis of the voltage signals recorded before and after training quenches is then presented and discussed, and the results of coil visual inspections reported.

43 PARTICLE ACCELERATORS↗

Measurements on Subscale Y-Ba-Cu-O Racetrack Coils at 77 K and Self-Field

YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) tapes carry significant amount of current at fields beyond the limit of Nb-based conductors. This makes the YBCO tapes a possible conductor candidate for insert magnets to increase the bore field of Nb{sub 3}Sn high-field dipoles. As an initial step of the YBCO insert technology development, two subscale racetrack coils were wound using Kapton-insulated commercial YBCO tapes. Both coils had two layers; one had 3 turns in each layer and the other 10 turns. The coils were supported by G10 side rails and waxed strips and not impregnated. The critical current of the coils was measured at 77 K and self-field. A 2D model considering the magnetic-field dependence of the critical current was used to estimate the expected critical current. The measured results show that both coils reached 80%-95% of the expected values, indicating the feasibility of the design concept and fabrication process.

43 PARTICLE ACCELERATORS↗

Test results of TQS03: a LARP shell-based Nb3Sn quadrupole using 108/127 conductor

Future insertion quadrupoles with large apertures and high gradients will be required for the Phase II luminosity upgrade (10{sup 35} cm{sup -2}s{sup -1}) of the Large Hadron Collider (LHC). Although improved designs, based on NbTi, are being considered as an intermediate step for the Phase I upgrade, the Nb{sub 3}Sn conductor is presently the best option that meets the ultimate performance goals for both operating field and temperature margin. As part of the development of Nb{sub 3}Sn magnet technology, the LHC Accelerator Research Program (LARP) developed and tested several 1-meter long, 90-mm aperture Nb{sub 3}Sn quadrupoles. The first two series of magnet used OST MJR 54/61 (TQ01 series) and OST RRP 54/61 (TQ02 series) strands. The third series (TQ03) used OST RRP 108/127 conductor. The larger number of sub-elements and the consequent reduction of the effective filament size, together with an increased fraction of copper and a lower Jc were expected to improve the conductor stability. The new coils were tested in the TQS03 series using a shell structure assembled with keys and bladders. The objective of the first test (TQS03a) was to evaluate the performances of the 108/127 conductor and, in particular, its behaviour at 1.9 K, while the second test (TQS03b) investigated the impact on high azimuthal pre-stress on the magnet performance. This paper reports on TQS03 fabrication, the strain gauge measurements performed during assembly, cool-down, excitation and the quench behavior of the two magnets.

43 PARTICLE ACCELERATORS↗

MAGNETIC FIELD MEASUREMENTS OF HD2, A HIgh Nb3Sn DIPOLE MAGNET

The Superconducting Magnet Program at Lawrence Berkeley National Laboratory has designed and tested HD2, a 1 m long Nb{sub 3}Sn accelerator-type dipole based on a simple block-type coil geometry with flared ends. HD2 represents a step toward the development of cost-effective accelerator quality magnets operating in the range of 13-15 T. The design was optimized to minimize geometric harmonics and to address iron saturation and conductor magnetization effects. Field quality was measured during recent cold tests. The measured harmonics are presented and compared to the design values.

43 PARTICLE ACCELERATORS↗

Test Results of LARP Nb3Sn Quadrupole Magnets Using a Shell-based Support Structure (TQS)

Among the magnet development program of a large-aperture Nb{sub 3}Sn superconducting quadrupole for the Large Hadron Collider luminosity upgrade, six quadrupole magnets were built and tested using a shell based key and bladder technology (TQS). The 1 m long 90 mm aperture magnets are part o fthe US LHC Accelerator Research Program (LARP) aimed at demonstrating Nb{sub 3}Sn technology by the year 2009, of a 3.6 m long magnet capable of achieving 200 T/m. In support of the LARP program the TQS magnets were tested at three different laboratories, LBNL, FNAL and CERN and while at CERN a technology-transfer and a four days magnet disassembly and reassembly were included. This paper summarizes the fabrication, assembly, cool-down and test results of the six magnets and compres measruements with design expectations.

43 PARTICLE ACCELERATORS↗

Assembly and Test of HD2, a 36 mm bore high field Nb3Sn Dipole Magnet

We report on the fabrication, assembly, and test of the Nb{sub 3}Sn dipole magnet HD2. The magnet, aimed at demonstrating the application of Nb{sub 3}Sn superconductor in high field accelerator-type dipoles, features a 36 mm clear bore surrounded by block-type coils with tilted ends. The coil design is optimized to minimize geometric harmonics in the aperture and the magnetic peak field on the conductor in the coil ends. The target bore field of 15 T at 4.3 K is consistent with critical current measurements of extracted strands. The coils are horizontally pre-stressed during assembly using an external aluminum shell pre-tensioned with water-pressurized bladders. Axial pre-loading of the coil ends is accomplished through two end plates and four aluminum tension rods. The strain in coil, shell, and rods is monitored with strain gauges during assembly, cool-down and magnet excitation, and compared with 3D finite element computations. Magnet's training performance, quench locations, and ramp-rate dependence are then analyzed and discussed.

43 PARTICLE ACCELERATORS↗

Use of High Resolution DAQ System to Aid Diagnosis of HD2b, a High Performance Nb3Sn Dipole

A novel voltage monitoring system to record voltage transients in superconducting magnets is being developed at LBNL. This system has 160 monitoring channels capable of measuring differential voltages of up to 1.5kV with 100kHz bandwidth and 500kS/s digitizing rate. This paper presents analysis results from data taken with a 16 channel prototype system. From that analysis we were able to diagnose a change in the current-temperature margin of the superconducting cable by analyzing Flux-Jump data collected after a magnet energy extraction failure during testing of a high field Nb{sub 3}Sn dipole.

43 PARTICLE ACCELERATORS↗

Construction and Test of 3.6 m Nb3Sn Racetrack Coils for LARP

Development of high-performance Nb{sub 3}Sn quadrupoles is one of the major goals of the LHC Accelerator Research Program (LARP). As part of this program, long racetrack magnets were made in order to check the fabrication steps for long Nb{sub 3}Sn coils, that the changes in coil length that take place during reaction and cooldown are correctly accounted for in the quadrupole design, and the use of a long aluminum shell for the support structure. This paper reports the construction of the first long Nb{sub 3}Sn magnet with racetrack coils 3.6 m long. The magnet reached a nominal 'plateau' at 9596 A after five quenches. This is about 90% of the estimated conductor limit. The peak field in the coils at this current was 11 T.

43 PARTICLE ACCELERATORS↗

Test and Analysis of 4 Technology Quadrupole Shell (TQS) models for LARP

Test results are reported on TQS02a, a second model in support of the development of a large-aperture Nb{sub 3}Sn superconducting quadrupole for the US LHC Accelerator Research Program (LARP). The magnet uses key and bladder technology with supporting iron yoke and an aluminum shell. Changes from the previous first model (tested in 2006) include: (1) Titanium island poles; (2) no axial island gaps during reaction; and (3) RRP Nb3Sn conductor. Design changes resulted from previous tests with three different magnet assemblies (TQS01a, TQS01b and TQS01c) using coils with bronze segmented islands, with gaps and MJR conductor The paper summarizes the assembly, cool-down and performance of TQS01a, TQS01b, TQS01c, and TQS02 and compares measurements with design expectations.

43 PARTICLE ACCELERATORS↗

LARP Long Nb3Sn Quadrupole Design

A major milestone for the LHC Accelerator Research Program (LARP) is the test, by the end of 2009, of two 4m-long quadrupole magnets (LQ) wound with Nb{sub 3}Sn conductor. The goal of these magnets is to be a proof of principle that Nb{sub 3}Sn is a viable technology for a possible LHC luminosity upgrade. The design of the LQ is based on the design of the LARP Technological Quadrupoles, presently under development at FNAL and LBNL, with 90-mm aperture and gradient higher than 200 T/m. The design of the first LQ model will be completed by the end of 2007 with the selection of a mechanical design. In this paper we present the coil design addressing some fabrication technology issues, the quench protection study, and three designs of the support structure.

43 PARTICLE ACCELERATORS↗

Measurement of Fast Voltage Transients in High-Performance Nb3Sn Magnets

The Superconducting Magnet group at Lawrence Berkeley National Laboratory has been developing Nb{sub 3}Sn high-field accelerator magnet technology for the last fifteen years. In order to support the magnet R&D effort, we are developing a diagnostic system that can help identify the causes of performance limiting quenches by recording small flux-changes within the magnet prior to quench-onset. These analysis techniques were applied to the test results from recent Nb{sub 3}Sn magnets. This paper will examine various types of events and their distinguishing characteristics. The present measurement techniques are discussed along with the design of a new data acquisition system that will substantially improve the quality of the recorded signals.

43 PARTICLE ACCELERATORS↗