Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Power System Resilience Considering Hurricane Storms and Generator Step-up Transformers

Power system resilience describes the system’s ability to withstand and recover quickly from unexpected power outages due to extreme events. As society’s electrification continues at a rapid rate, it is imperative electric infrastructure is designed and operated with extra security. This work studies the impact of severe hurricane storms on the power system located along the United States’ Eastern Seaboard. Specific focus is designated to steady state system operation and loss of large generation step up power transformers. A series of phasor domain power system simulations are conducted to determine the critical point at which the system loses steady state operability. Additionally, active power load shedding and generator dispatching are studied as mitigation and recovery strategies. Results indicate generator dispatching as an effective proactive mitigation strategy and load shedding as an effective recovery strategy.

Liu, Yilu↗

Hardware-in-the-Loop Testing of Wide-Area Damping Controller for Field Implementation in Large-scale Power Grid

In our previous work, an adaptive measurement-driven wide-area damping controller (WADC) for suppressing inter-area oscillations has been proposed and a hardware prototype was developed and validated through hardware-in-the-loop tests. As a continuation of the work, this paper introduces a WADC software prototype to handle the realistic challenges for field implementation in the control room of the power grid. The WADC software is developed and operated as an openPDC adapter with a graphical user interface (GUI) to monitor the WADC inputs and output, the communication delays and other variables. The software prototype has been fully tested through an enhanced hardware-in-the-loop (HIL) test setup. Its performance is verified under various realistic communication uncertainties, such as random time delays and data losses, with different communication protocols. The experiment results have proven the WADC software can deliver sufficient damping to suppress the targeted oscillation mode in handling various communication uncertainties for future field deployment.

Jia, Xinlan↗

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

Measurement-Based Approach for Inertia-Trend Analysis of the US Western Interconnection

Rising deployment of inverter-based resources (IBRs), characterized by a lack of rotating mass, is decreasing the total inertia of the system. This can lead to an increased Rate of Change of Frequency (RoCoF) during the disturbance and false activation of protective devices. There is a need to assess the inertia over the past decade amidst the evolving landscape of renewable energy sources to develop strategies for integrating energy storage, enhancing resilience measures, and ensuring the stable and reliable operation of the grid. Therefore, a realistic assessment of the inertia trend using a measurement-based approach that addresses the limitations of existing models is proposed. An inertia study of the Western Interconnection in the United States is performed utilizing the data from 2013 to 2022, obtained from FNET/ GridEye network. The three-second RoCoF time window is chosen for the study as it showed an optimum balance between a strong correlation with the power imbalance (ΔP) and minimum inclusion of primary response from governor. The obtained inertia trend result shows a small percentage declination of inertia over the decade. By examining the result alongside a generation mix graph, insights are gained into the dynamic interplay between shifting energy landscape and system inertia.

Dulal, Saurav↗

Method for Coupled Electromagnetic and Circuit Simulations to Evaluate Surge Arrester Performance in Protecting Equipment Against E1 HEMP

Surge arrester behavioral modeling for realistic systems embedded in an E1 high-altitude electromagnetic pulse environment inherently encompasses three interconnected complications: (1) the need to account for signal propagation across two domains, electromagnetics and electrical; (2) the need to include both linear and nonlinear circuit components in the analysis; and (3) the need to understand that the over-current and over-voltage mitigation performance is dependent not only on the properties of the surge arrester and protected load but also on the topology of the overall electrical network. This study presents a framework to address these challenges in a systematic manner to consider the effectiveness of protective measures for a common class of equipment in power generation facilities. Full-wave simulations were carried out to derive circuit-domain (i.e., lumped element–based) equivalent models for the excitation waveform and the physical components of the system. Then, these equivalent models were imported to a circuit solver and combined with a high-frequency surge arrester model to evaluate mitigation performance. The methodology outlined is general enough such that it can be applied for other electromagnetic interference problems that involve E2/E3 HEMP or microwave emissions.

42 ENGINEERING↗

Impact of the Exciter and Governor Parameters on Forced Oscillations

In recent years, the frequency of forced oscillation events due to control system malfunctions or improper parameter settings has increased. Tuning the parameters of exciters and governor models is crucial for maintaining power system stability. Traditional simulation studies typically involve small transient disturbances or step changes to find optimal parameter sets, but existing optimization algorithms often fall short in fine-tuning for forced oscillations. Identifying the sensitive parameters within these control models is essential for ensuring stability during large, sustained disturbances. This study focuses on identifying these critical exciter and governor model parameters by analyzing their influence on sustained forced oscillations. Using Kundur’s two-area system, we analyze common exciter models such as SCRX, ESST1A, and AC7B, along with governor models like GAST, HYGOV, and GGOV1, utilizing PSS®E software version 34. Sustained forced oscillations are injected at generator-1 of area-1, with individual parameter changes dynamically simulated. By considering a local oscillation frequency of 1.4 Hz and an inter-area oscillation mode of 0.25 Hz, we analyze the impact of each parameter change on the magnitude and frequency of forced oscillations as well as on active and reactive power outputs. This novel approach highlights the most influential parameters of each tested model—such as exciter, governor, and turbine gains, as well as time constant parameters—on the impact of forced oscillations. Based on our findings, the sensitive parameters of each tested model are ranked. These would provide valuable insights for industry operators to fine-tune control settings during oscillation events, ultimately enhancing system stability.

42 ENGINEERING↗

Development of Real-Time High-Density Pulsar Data Transmission and Processing for Grid Synchronization

Taking advantage of the extreme stability of the pulsar period, it can serve as the timing source for grid synchronization to compensate for the timing drift instigated by the loss of GPS signal. Nevertheless, the real-time transmission and processing of the pulsar data suffer from its high-frequency data rate, varying from megahertz to gigahertz, resulting in reduced computing speed and increased time delay. To mitigate this issue, the hardware and software frameworks are implemented for the high-density pulsar data transmission and processing for grid synchronization in this research. Initially, the high-density pulsar data is transferred using open-source software. The complementary duty cycle timing module is designed to coordinate the operation of the dual-channel high-speed interface and software. Subsequently, the multiple-threading is applied to the receiving, parsing, and splicing pulsar data. Next, the pulsar signal extraction method is implemented based on the polyphase filterbank and time of arrival estimation. Ultimately, real-time performance verification experiments are carried out for different components under two hardware platforms. Finally, the results demonstrate that only 0.482 s is required for processing 4 Gigabyte data through multiple-threading, which is 3.8 times faster than the single thread. The pulsar signal extraction can also be executed within 707 ms for 4.8 seconds of data, thereby indicating that real-time requirements can be met.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100): Final Report

The Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) is a comprehensive analysis based on extensive stakeholder input of possible pathways for Puerto Rico to achieve its goal of 100% renewable energy by 2050. PR100 was an integrated effort drawing on expertise and capabilities of the contributing national laboratories that explored possible pathways for Puerto Rico to achieve its goal of 100% renewable energy in the long term (by 2050), increase reliability and resilience in the immediate term (within the next few years), and work toward energy justice. The purpose of the study is to provide decision support and inform investment decisions for implementers of Puerto Rico's energy transition. See NREL/TP-6A20-88614 for the Spanish translation of this report.

100% renewable energy target↗

El Estudio de Resiliencia de la Red Electrica de Puerto Rico y Transiciones a Energia 100% Renovable (PR100): Informe Final [Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100): Final Report]

El Estudio de Resiliencia de la Red de Puerto Rico y Transiciones a Energia 100% Renovable (PR100) es un analisis integral basado en amplios aportes de las partes interesadas sobre posibles caminos para que Puerto Rico alcance su meta de 100% de energía renovable para 2050. PR100 fue un esfuerzo integrado que se baso en experiencia y capacidades de los laboratorios nacionales contribuyentes que exploraron posibles caminos para que Puerto Rico logre su objetivo de 100% de energía renovable en el largo plazo (para 2050), aumente la confiabilidad y la resiliencia en el plazo inmediato (dentro de los proximos anos), y trabajar hacia la justicia energetica. El proposito del estudio es brindar apoyo a las decisiones e informar las decisiones de inversion para los implementadores de la transicion energetica de Puerto Rico. See NREL/TP-6A20-88384 for the English translation of this report.

100% renewable energy target↗

Ambient-Frequency-Data Based System-Level Inertia Estimation Using Physical Equation and its Practice on Hawaii Islands

Here, in this paper, a practical ambient-frequency-data-based inertia estimation method using a physical equation is proposed and validated by real measurement data from Hawaii island grids. With high renewable penetration, accurate inertia estimation is important and urgent. Ambient frequency oscillation always exists in power grids, so the proposed method has advantages of real-time inertia estimation and no need for additional disturbances. This paper first developed the physical equation for inertia estimation to offer a clear mechanism for easy implementation in practice. To apply the proposed method in actual grids, a practical method to extract the ambient frequency oscillation from frequency measurement is further proposed. The inertia estimation using the physical equation is validated by KIUC simulation data and HECO field data, in which error rates are around 2% and 8%, respectively. Practical inertia estimation is challenging due to the large amounts of resources contributing to the power grid's effective inertia, but the method provided in this paper can offer a novel way for practical inertia estimation, which can help renewable penetration to boost carbon-free grid.

14 SOLAR ENERGY↗

Effects on Structure’s Electromagnetic Shielding Effectiveness Considering Penetrating Cables Coupling Energy from HEMP Event

The threat of weaponized electromagnetic pulse (EMP) is a serious factor in defining power system resilience. Without adequate knowledge regarding the interaction between EMP and power system infrastructure, system personnel may be unable to plan for and operate during an EMP event and major blackouts could occur. This work studies the interaction between EMP and structures, specifically analyzing the shielding effectiveness of buildings emulating power generation facilities. The main focus is to determine how penetrating cables affect the structure’s shielding effectiveness. Several cable parameters including height above ground, radius, termination configuration, and length are analyzed via computational electromagnetic simulations. Results demonstrated penetrating cables can significantly diminish a structure’s shielding effectiveness, especially the electric field. Length of cable is the most influential parameter.

Mignardot, David↗

PR100 Final Results

This presentation includes a summary of the final results from the Puerto Rico Grid Resilience and Transition to 100% Renewable Energy Study (PR100). Led by the U.S. Department of Energy's Grid Deployment Office and the National Renewable Energy Laboratory, and funded by the Federal Emergency Management Agency, the PR100 Study was a two-year effort resulting in stakeholder-driven pathways for Puerto Rico to meet its clean energy goals. For Spanish version see https://www.nrel.gov/docs/fy24osti/88975.pdf.

100% renewable energy target↗

Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model

Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.

14 SOLAR ENERGY↗

Data Security Defense: Modeling and Detection of Synchrophasor Data Spoofing Attack for Grid Edge

Data security and cyberattack have become critical issues in the distributed power system where adversaries can swap the source information of sensors or even spoof and alter measurements. However, the cyber security of the power system is challenged by the unpredictability and stealth of the spoofing attacks. Here, to protect the data security at the grid edge, this paper developed a synchrophasor data spoofing attack detection framework based on the time-frequency feature extraction techniques including the short-time Fourier transform (STFT) and object detection network for real-time synchrophasor data categorization and spoofing attack localization. The proposed approach outperforms earlier work in terms of spoofing attack detection and offers a vital localization function employing distributed synchrophasor sensors.