Engineering Papers⌕ Search

Engineering topics

Liu, H

Publications and source records attributed to Liu, H.

At least 37 records · Page 2

WE-FG-202-12: Investigation of Longitudinal Salivary Gland DCE-MRI Changes

Purpose: To determine the correlation between dose and changes through treatment in dynamic contrast enhanced (DCE) MRI voxel parameters (Ktrans, kep, Ve, and Vp) within salivary glands of head and neck oropharyngeal squamous cell carcinoma (HNSCC) patients. Methods: 17 HNSCC patients treated with definitive radiation therapy completed DCE-MRI scans on a 3T scanner at pre-treatment, mid-treatment, and post-treatment time points. Mid-treatment and post-treatment DCE images were deformably registered to pre-treatment DCE images (Velocity software package). Pharmacokinetic analysis of the DCE images used a modified Tofts model to produce parameter maps with an arterial input function selected from each patient’s perivertebral space on the image (NordicICE software package). In-house software was developed for voxel-by-voxel longitudinal analysis of the salivary glands within the registered images. The planning CT was rigidly registered to the pre-treatment DCE image to obtain dose values in each voxel. Voxels within the lower and upper dose quartiles for each gland were averaged for each patient, then an average of the patients’ means for the two quartiles were compared. Dose-relationships were also assessed by Spearman correlations between dose and voxel parameter changes for each patient’s gland. Results: Changes in parameters’ means between time points were observed, but inter-patient variability was high. Ve of the parotid was the only parameter that had a consistently significant longitudinal difference between dose quartiles. The highest Spearman correlation was Vp of the sublingual gland for the change in the pre-treatment to mid-treatment values with only a ρ=0.29. Conclusion: In this preliminary study, there was large inter-patient variability in the changes of DCE voxel parameters with no clear relationship with dose. Additional patients may reduce the uncertainties and allow for the determination of the existence of parameter and dose relationships.

60 APPLIED LIFE SCIENCES↗

WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-209-08: Next Generation Dedicated 3D Breast Imaging with XACT

Purpose: Exposure to radiation increases the risk of cancer. We have designed a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, an X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to conventional breast CT. Methods: Theoretical calculations are done to determine the appropriate X-ray energy and ultrasound frequency in breast XACT imaging. A series of breast CT image along the coronal plane from a patient with calcifications in the breast tissue are used as the source image. HU value based segmentation is done to distinguish the skin, adipose tissue, glandular tissue, breast calcification, and chest bone from each CT image. X-ray dose deposition in each pixel is calculated based on the tissue type by using GEANT4 Monte Carlo toolkits. The initial pressure rise caused by X-ray energy deposition is calculated according to tissue properties. Then, the X-ray induced acoustic wave propagation is simulated by K-WAVE toolkit. Breast XACT images are reconstructed from the recorded time-dependent ultrasound waves. Results: For imaging a breast with large size (16cm in diameter at chest wall), the photon energy of X-ray source and the central frequency of ultrasound detector is determined as 20keV and 5.5MHz. Approximately 10 times contrast between a calcification and the breast tissue can be acquire from XACT image. The calcification can be clearly identified from the reconstructed XACT image. Conclusion: XACT technique takes the advantages of X-ray absorption contrast and high ultrasonic resolution. With the proposed innovative technology, one can potentially reduce radiation dose to patient in 3D breast imaging as compared with current x-ray modalities, while still maintaining high imaging contrast and spatial resolution.

60 APPLIED LIFE SCIENCES↗

SU-E-I-37: Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation

Purpose: To investigate the eye lens dose reduction by CT scan with organ based tube current modulation (OBTCM) using GPU Monte Carlo code ARCHER-CT. Methods: 36 X-ray sources and bowtie filters were placed around the patient head with the projection angle interval of 10° for one rotation of CT scan, each projection was simulated respectively. The voxel eye models with high resolution(0.1mm*0.1mm*0.1mm) were used in the simulation and different tube voltage including 80kVp, 100kVp, 120kVp and 140kVp were taken into consideration. Results: The radiation doses to the eye lens increased with the tube voltage raised from 80kVp to 140kVp, and the dose results from 0° (AP) direction are much higher than those from 180° (PA) direction for all the 4 different tube voltage investigated. This 360° projection dose characteristic enables organ based TCM, which can reduce the eye lens dose by more than 55%. Conclusion: As the eye lens belongs to superficial tissues, its radiation dose to external exposure like CT is direction sensitive, and this characteristic feature makes organ based TCM to be an effective way to reduce the eye lens dose, so more clinical use of this technique were recommended. National Nature Science Foundation of China(No.11475047)

60 APPLIED LIFE SCIENCES↗

SU-E-I-65: Estimation of Tagging Efficiency in Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI

Purpose: pCASL was recommended as a potent approach for absolute cerebral blood flow (CBF) quantification in clinical practice. However, uncertainties of tagging efficiency in pCASL remain an issue. This study aimed to estimate tagging efficiency by using short quantitative pulsed ASL scan (FAIR-QUIPSSII) and compare resultant CBF values with those calibrated by using 2D Phase Contrast (PC) MRI. Methods: Fourteen normal volunteers participated in this study. All images, including whole brain (WB) pCASL, WB FAIR-QUIPSSII and single-slice 2D PC, were collected on a 3T clinical MRI scanner with a 8-channel head coil. DeltaM map was calculated by averaging the subtraction of tag/control pairs in pCASL and FAIR-QUIPSSII images and used for CBF calculation. Tagging efficiency was then calculated by the ratio of mean gray matter CBF obtained from pCASL and FAIR-QUIPSSII. For comparison, tagging efficiency was also estimated with 2D PC, a previously established method, by contrast WB CBF in pCASL and 2D PC. Feasibility of estimation from a short FAIR-QUIPSSII scan was evaluated by number of averages required for obtaining a stable deltaM value. Setting deltaM calculated by maximum number of averaging (50 pairs) as reference, stable results were defined within ±10% variation. Results: Tagging efficiencies obtained by 2D PC MRI (0.732±0.092) were significantly lower than which obtained by FAIRQUIPPSSII (0.846±0.097) (P<0.05). Feasibility results revealed that four pairs of images in FAIR-QUIPPSSII scan were sufficient to obtain a robust calibration of less than 10% differences from using 50 pairs. Conclusion: This study found that reliable estimation of tagging efficiency could be obtained by a few pairs of FAIR-QUIPSSII images, which suggested that calibration scan in a short duration (within 30s) was feasible. Considering recent reports concerning variability of PC MRI-based calibration, this study proposed an effective alternative for CBF quantification with pCASL.

60 APPLIED LIFE SCIENCES↗

SU-E-I-85: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner

Purpose: To quantify the simulated absorbed dose delivered for a typical scan from a commercially available microCT scanner in order to aid in the dose estimation. Methods: The simulations were conducted using the Geant4 Monte Carlo Toolkit (version 10) with the standard electromagnetic classes. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating the energy fluence and angular distributions of generated photons, spatial dimensions of nominal source-to-object and source-to-detector distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) with a 300 angular spread from the source for the 90 kVp X-ray beams with no additional filtration. The nominal distances from the source to object consisted of three setups: 154.0 mm, 104.0 mm, and 51.96 mm. Our simulations recorded the dose absorbed in a cylindrical phantom of PMMA with a fixed length of 2 cm and varying radii (10, 20, 30 and 40 mm) using 100 million incident photons. The averaged absorbed dose in the object was then quantified for all setups. An exposure measurement of 417 mR was taken using a Radcal 9095 system utilizing 10×9–180 ion chamber with the given technique of 90 kVp, 63 μA, and 12 s. The exposure rate was also simulated with same setup to calculate the conversion factor of the beam current and the number of incident photons. Results: For a typical cone-beam scan with non-filtered 90kVp, the dose coefficients (the absorbed dose per mAs) were 2.614, 2.549 and 2.467 μGy/mAs under source to object distance of 104 mm for the object diameters of 10 mm, 20 mm and 30 mm, respectively. Conclusion: A look-up table was developed where an investigator can estimate the delivered dose using this particular microCT given the scanning protocol (kVp and mAs) as well as the size of the scanned object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-47: Comparison of Online Image Registrations of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac Imaging Systems

Purpose To compare online image registrations of TrueBeam cone-beam CT (CBCT) and BrainLab ExacTrac imaging systems. Methods Tests were performed on a Varian TrueBeam STx linear accelerator (Version 2.0), which is integrated with a BrainLab ExacTrac imaging system (Version 6.0.5). The study was focused on comparing the online image registrations for translational shifts. A Rando head phantom was placed on treatment couch and immobilized with a BrainLab mask. The phantom was shifted by moving the couch translationally for 8 mm with a step size of 1 mm, in vertical, longitudinal, and lateral directions, respectively. At each location, the phantom was imaged with CBCT and ExacTrac x-ray. CBCT images were registered with TrueBeam and ExacTrac online registration algorithms, respectively. And ExacTrac x-ray image registrations were performed. Shifts calculated from different registrations were compared with nominal couch shifts. Results The averages and ranges of absolute differences between couch shifts and calculated phantom shifts obtained from ExacTrac x-ray registration, ExacTrac CBCT registration with default window, ExaxTrac CBCT registration with adjusted window (bone), Truebeam CBCT registration with bone window, and Truebeam CBCT registration with soft tissue window, were: 0.07 (0.02–0.14), 0.14 (0.01–0.35), 0.12 (0.02–0.28), 0.09 (0–0.20), and 0.06 (0–0.10) mm, in vertical direction; 0.06 (0.01–0.12), 0.27 (0.07–0.57), 0.23 (0.02–0.48), 0.04 (0–0.10), and 0.08 (0– 0.20) mm, in longitudinal direction; 0.05 (0.01–0.21), 0.35 (0.14–0.80), 0.25 (0.01–0.56), 0.19 (0–0.40), and 0.20 (0–0.40) mm, in lateral direction. Conclusion The shifts calculated from ExacTrac x-ray and TrueBeam CBCT registrations were close to each other (the differences between were less than 0.40 mm in any direction), and had better agreements with couch shifts than those from ExacTrac CBCT registrations. There were no significant differences between TrueBeam CBCT registrations using different windows. In ExacTrac CBCT registrations, using bone window led to better agreements than using default window.

60 APPLIED LIFE SCIENCES↗

SU-E-T-65: A Prospective Trial of Open Face Masks for Head and Neck Radiotherapy

Purpose: Open face head and neck masks allow for active patient monitoring during treatment and may reduced claustrophobia and anxiety compared to closed masks. The ability of open masks to limit intrafraction motion and to preserve the patient shape/position from simulation over protracted treatments should be considered. Methods: Thirty-two head and neck patients were prospectively randomized to treatment in a closed mask or a novel open face mask. All patients received daily volumetric imaging. The daily images were automatically rigidly registered to the planning CT’s offline using a commercial image processing tool. The shifts needed to optimize the registration, the mutual information coefficient (MI), and the Pearson correlation (PC) coefficients were recorded to evaluate shape preservation. The open group was set-up and monitored with surface imaging at treatment. The real time surface imaging information was recorded to evaluate intrafraction motion. Results: Sixteen patients were included in each group. Evaluations were made over a total of 984 fractions. The mean MI and PC showed significantly higher shape preservation for the open group than for the closed group (p = 0). The mean rotations for the open group were smaller or < 0.15° larger versus the closed group. The mean intrafraction motion for the open group was 0.93 +/−0.99 mm (2 SD). The maximum single fraction displacement was 3.2 mm. Fourteen of 16 patients showed no significant correlation of motion with fraction number (p > 0.05). Conclusion: The open masks preserved shape as well as the closed masks, and they limited motion to < 2 mm for 95% of the treated fractions. These results are consistent over treatment courses of up to 35 fractions. The open mask is suitable for treatment with or without active monitoring. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-177: Clinical Experience with Spirometer Guided Breath Hold Lung SBRT

Purpose: Tumor motion in lung SBRT is typically managed by creating an internal target volume (ITV) based on 4D-CT information. Another option, which may reduce lung dose and imaging artifact, is to use a breath hold (BH) during simulation and delivery. Here we evaluate the reproducibility of tumor position at repeated BH using a newly released spirometry system. Methods: Three patients underwent multiple BH CT’s at simulation. All patients underwent a BH cone beam CT (CBCT) prior to each treatment. All image sets were registered to a patient’s first simulation CT based on local bony anatomy. The gross tumor volume (GTV), and the diaphragm or the apex of the lung were contoured on the first image set and expanded in 1 mm increments until the GTVs and diaphragms on all image sets were included inside an expanded structure. The GTV and diaphragm margins necessary to encompass the structures were recorded. Results: The first patient underwent 2 BH CT’s and fluoroscopy at simulation, the remaining patients underwent 3 BH CT’s at simulation. In all cases the GTV’s remained within 1 mm expansions and the diaphragms remained within 2 mm expansions on repeat scans. Each patient underwent 3 daily BH CBCT’s. In all cases the GTV’s remained within a 2 mm expansions, and the diaphragms (or lung apex in one case) remained within 2 mm expansions at daily BH imaging. Conclusions: These case studies demonstrate spirometry as an effective tool for limiting tumor motion (and imaging artifact) and facilitating reproducible tumor positioning over multiple set-ups and BH’s. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

SU-E-T-450: How Important Is a Reproducible Breath Hold for DIBH Breast Radiotherapy?

Purpose: Deep inspiration breath hold (DIBH) for left-sided breast cancer has been shown to reduce heart dose. Surface imaging helps to ensure accurate breast positioning, but does not guarantee a reproducible breath hold (BH) at DIBH treatments. We examine the effects of variable BH positions for DIBH treatments. Methods: Twenty-Five patients with free breathing (FB) and DIBH scans were reviewed. Four plans were created for each patient: 1) FB, 2) DIBH, 3) FB-DIBH – the DIBH plans were copied to the FB images and recalculated (image registration was based on breast tissue), and 4) P-DIBH – a partial BH with the heart shifted midway between the FB and DIBH positions. The FB-DIBH plans give “worst case” scenarios for surface imaging DIBH, where the breast is aligned by surface imaging but the patient is not holding their breath. Students t-tests were used to compare dose metrics. Results: The DIBH plans gave lower heart dose and comparable breast coverage versus FB in all cases. The FB-DIBH plans showed no significant difference versus FB plans for breast coverage, mean heart dose, or maximum heart dose (p >= 0.10). The mean heart dose differed between FB-DIBH and FB by < 2 Gy for all cases, the maximum heart dose differed by < 2 Gy for 21 cases. The P-DIBH plans showed significantly lower mean heart dose than FB (p = 0.01). The mean heart doses for the P-DIBH plans were < FB for 22 cases, the maximum dose < FB for 18 cases. Conclusions: A DIBH plan delivered to a FB patient set-up with surface imaging will yield similar dosimetry to a plan created and delivered FB. A DIBH plan delivered with even a partial BH can give reduced heart dose compared to FB techniques when the breast tissue is well aligned.

60 APPLIED LIFE SCIENCES↗

SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation

Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulation (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)

60 APPLIED LIFE SCIENCES↗

SU-E-T-621: Analysis of Robustness of Proton Pencil Beam Scanning Technique for Delivery of Craniospinal Irradiation

Purpose: To investigate the robustness and safety of craniospinal irradiation (CSI) planned with a proton pencil beam scanning (PBS) technique which overcomes the complexity of the planning associated with feathering match lines. Methods: Six CSI patients were planned with gradient-dose matching using PBS technique. Uniform dose coverage to the entire target volumes was achieved with averaged junction lengths of 6.9±0.3 cm. Robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in longitudinal direction and compared with the original non-shifted plan with metrics of conformity number (CN) and homogeneity index (HI). An anthropomorphic phantom study using film measurements was also carried out on a plan with 5 cm junction length. Results: For a given junction length, the dose errors were directly proportional to the setup errors. Setup errors of 3 mm from each field caused on average 3.5% lower CN and 2.1% higher HI. Minimal D95% to PTV and D98% to CTV were reduced by 2.2%±1.5% and 2.8%±1.7% respectively. A drop of maximal 6.8%±5.5% on the minimal dose to the cribriform plate was also observed. When the junction length was 5cm or longer, these 3mm setup errors from each field resulted in up to 12% dose errors. Consistent results were reached between film measurements and planned dose profiles in the junction area. Due to near-zero exit doses beyond the target volume, sparing of anterior organs such as heart, liver, lung and kidney were observed. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the CSI treatment with matched proton fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust and safe to longitudinal setup errors compared to conventional feathering methods.

60 APPLIED LIFE SCIENCES↗