Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PELICAN Status Report for Year 2021

The Pressure Drop Experimental Loop for Investigations of Core Assemblies in Advanced Nuclear Reactors, PELICAN, is a novel experimental facility designed and constructed to recreate the prototypic full scale hydraulic flow conditions for the Versatile Test Reactor (VTR) currently under development by the U.S. Department of Energy. To support VTR design efforts, PELICAN is used to replicate VTR’s primary heat transport system (PHTS) in the core assembly region. The measurement objectives for data generated from this test facility are to mimic the prototypic VTR assembly and to meet the validation needs for code calculations and simulations of the reference design for the VTR core. These objectives focus on the need to validate pressure drop results across the various segments of the fuel assembly, including the axial reflectors, fuel, and transition regions, as they relate directly to the pumping power and safety behavior of the reactor. In the following sections, the major milestones for the experimental work performed on PELICAN over the calendar year (CY) 2021 are presented. In the next section, we discuss the assembly and shakedown testing of the facility. In Section 3, an analysis of the errors in the major measurements is performed. In Section 4 and 5 we present the results from the first set of test articles placed inside the loop. The design of the remaining test articles as part of the full assembly are shown in Section 6 and the conclusion and path forward for the following year, CY22 is given in the final section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Simulation of the Natural Convection Shutdown Heat Removal Test Facility Using SAM

Natural convection systems are a promising method to passively remove heat from reactor cavities during loss of forced flow accident scenarios. In this work at Argonne National Laboratory (ANL), a highly instrumented Natural Convection Shutdown Heat Removal Test Facility (NSTF) was used to demonstrate the effectiveness of air-cooled natural convection systems. In previous work, RELAP5-3D simulations were performed on this facility with favorable comparisons to experiment for mass flow rate, pressure drop, air temperature increase, and air velocity. Both experimental and simulation efforts with this facility present a useful opportunity to perform a benchmark study with the System Analysis Module (SAM). SAM is an advanced thermal-hydraulic system code currently in development at ANL for advanced non-light water reactor safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RCCS Testing with the Water-based NSTF: Year-1 Single-Phase Results

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed to generate validation data for passive decay heat removal systems of advanced reactors. Located at Argonne National Laboratory, the Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS). This report serves as a summary of the single-phase testing results obtained during the programs first year of matrix testing. An introduction to the high-level program objectives is first presented, followed by a brief summary of facility design, instrumentation, and control systems. Details of the NQA-1 driven test method are included, which govern the programs quality assurance requirements and provide a background for the testing strategy and procedures. Checkout activities, including verification of gross system mass and energy balances, heat loss quantification, and isothermal facility characterization, were performed early in the first year and results presented in this report. These tests have identified relevant facility characteristics such as K-factors, frictional pressure losses, parasitic heat loss rates, and transient heating response. Results are then presented from four accepted matrix tests where the facility established a steady-state, single-phase mode of flow operation. All matrix tests were performed with an identical top-level procedure: first initiating a heater power ramp to target levels, and then holding power levels constant until the facilities structural members and network piping reached thermal equilibrium. Upon obtaining stable thermal and hydraulic conditions, active cooling was initiated off of the bulk storage tank to maintain constant riser inlet temperatures of 30°C. This steady-state period was then held for a minimum required duration, at which point the heaters were ramped down and test concluded. The two baseline tests completed reflect conditions prototypic to the full scale plant at both normal operation, and design basis Depressurized Loss of Forced Cooling (DLOFC) conditions. These parameters are defined by full RCCS decay heat loads of 1.4 MWt and 2.1 MWt, which translate to NSTF scale thermal power levels of 34.4 kWt and 51.6 kWt, respectively. Two additional tests were also conducted, which repeated baseline cases but included modification by single parameter variations in decay heat load, or heater power, at 700 kWt, and 2.8 MWt. Finally, a scoping test was performed to demonstrate the facilities ability to operate in a two-phase mode of operation. The facility successfully operated for a 3-hour period at this mode, reaching peak inventory temperatures of 105°C and condensing approximately 50 gallons of boil-off inventory. The testing parameters for this demonstration were based off the design basis DLOFC condition, and will be the reference for new baseline cases as the program moves forward with two-phase matrix testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress Report on Computational Analyses of Water-Based NSTF

CFD analysis has been focused on important component-level phenomena using STARCCM+ to supplement the system analysis of integral system behavior. A notable area of interest was the cavity region. This area is of particular interest for CFD analysis due to the multi-dimensional flow and complex heat transfer (thermal radiation heat transfer and natural convection), which are not simulated directly by RELAP5. CFD simulations allow for the estimation of the boundary heat flux distribution along the riser tubes, which is needed in the RELAP5 simulations. The CFD results can also provide additional data to help establish what level of modeling detail is necessary in RELAP5. It was found that the flow profiles in the cavity region are simpler for the water-based concept than for the air-cooled concept. The local heat flux noticeably increases axially, and is higher in the fins than in the riser tubes. These results were utilized in RELAP5 simulations as boundary conditions, to provide better temperature predictions in the system level analyses. It was also determined that temperatures were higher in the fins than the riser tubes, but within design limits for thermal stresses. Higher temperature predictions were identified in the edge fins, in part due to additional thermal radiation from the side cavity walls.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanisms Engineering Test Loop - Phase 1 Status Report

This report documents the current status of the Mechanisms Engineering Test Loop (METL) as of the end of FY2016. Currently, METL is in Phase I of its design and construction. Once operational, the METL facility will test small to intermediate-scale components and systems in order to develop advanced liquid metal technologies. Testing different components in METL is essential for the future of advanced fast reactors as it will provide invaluable performance data and reduce the risk of failures during plant operation.

42 ENGINEERING↗

Final Project Report on Computational Modeling and Analysis of Air-Based NSTF

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). The air-cooled RCCS uses natural convection to drive the flow of air from outside the power plant to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a ½ - scale model of the primary features of one conceptual air-cooled RCCS design. The NSTF program performs ex-vessel, passive heat removal experiments in support of Department of Energy Office of Nuclear Energy’s Advanced Reactor Technology (ART) program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗