International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard

Herein, a nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Qualitative assessment of uranium ore concentrates and related materials using scanning electron microscopy

Several studies have evaluated the morphology of uranium compounds produced under controlled conditions at the laboratory scale, but it is unclear whether the morphological characteristics of these materials persist in commercially produced uranium ore concentrates (UOCs). To assess the morphology in “real-world” UOCs, we qualitatively evaluated the morphological profile of secondary electron images from over 100 commercial UOCs using a previously published lexicon. We observe differences between samples with differing chemical composition and samples with similar chemical composition and differing provenance. Further, this work contextualizes morphology for commercially produced UOCs and will provide a basis for future machine learning efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

Exploring the use of thorium isotope compositions and concentrations as nuclear forensic signatures for uranium ore concentrates

This interlaboratory study measured thorium concentrations and isotope compositions in uranium ore concentrates from different geographical locations to examine whether thorium impurities may be useful forensic signatures for uranium ore concentrates found out of regulatory control. Measured 230 Th/ 232 Th in fifteen uranium ore concentrates record over three orders of magnitude of compositional variation. Results demonstrate that 230 Th/ 232 Th used in combination with U/Th ratios resulted in a unique signature for individual uranium ore concentrates from different processing locations. Data presented here suggest potential for 230 Th/ 232 Th and U/Th to be used as comparative signatures to investigate the provenance of seized uranium ore concentrates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Molybdenum isotope compositions of uranium ore concentrates by double spike MC-ICP-MS

The molybdenum (Mo) isotope composition of uranium ore concentrate (UOC) has been proposed as a nuclear forensic signature due to the ubiquitous presence of Mo in the nuclear fuel cycle and to the possibility that different UOC production pathways lead to characteristic Mo isotope fractionation. Furthermore, Mo forms a volatile hexafluoride which leads to the retainment of Mo in the nuclear fuel cycle through U enrichment and reactor operation processes. As a result, it is possible that the nuclear fuel cycle generates a rich array of Mo isotope signatures. The first step in interpreting Mo isotope signatures generated during the nuclear fuel cycle is to characterize the Mo isotope composition of starting materials. In this study, a suite of UOC samples were analyzed for their Mo isotope composition in order to constrain the range of Mo isotope compositions entering the front end of the nuclear fuel cycle. Analytical protocols were developed to purify Mo from a U rich matrix prior to Mo isotope analysis by double spike MC-ICP-MS. A >3‰ variation in the 98 Mo/ 95 Mo ratio was observed in the suite of UOC samples with δ 98 Mo ranging from -1.15 to +1.96‰ relative to the NIST 3134 Mo standard reference material. The δ98Mo range observed in the UOC samples is very similar to the δ 98 Mo range observed in crustal igneous rocks and Mo-bearing minerals, suggesting that Mo isotope variability in UOC is driven by variability in the parent U ores. However, Mo isotope fractionation during UOC production is evident with one of the UOC samples being isotopically heavy relative to its parent U ore by 0.75‰, suggesting that different UOC production processes also contribute to the total Mo isotope variability observed. Overall, it is expected that the Mo isotope signatures generated during enrichment and reactor process will be clearly discernible from those generated during UOC production.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Northwest Africa 8159 martian meteorite: Expanding the martian sample suite to the early Amazonian

Northwest Africa (NWA) 8159 is an augite-rich shergottite, with a mineralogy dominated by Ca-, Fe-rich pyroxene, plagioclase, olivine, and magnetite. NWA 8159 crystallized from an evolved melt of basaltic composition under relatively rapid conditions of cooling, likely in a surface lava flow or shallow sill. Redox conditions experienced by the melt shifted from relatively oxidizing (with respect to known Martian lithologies, ~QFM) on the liquidus to higher oxygen fugacity (~QFM + 2) during crystallization of the groundmass, and under subsolidus conditions. This shift resulted in the production of orthopyroxene and magnetite replacing olivine phenocryst rims. NWA 8159 contains both crystalline and shock-amorphized plagioclase (An 50–62 ), often observed within a single grain; based on known calibrations we bracket the peak shock pressure experienced by NWA 8159 to between 15 and 23 GPa. The bulk composition of NWA 8159 is depleted in LREE, as observed for Tissint and other depleted shergottites; however, NWA 8159 is distinct from all other martian lithologies in its bulk composition and oxygen fugacity. Here, we obtain a Sm-Nd formation age of 2.37 ± 0.25 Ga for NWA 8159, which represents an interval in Mars geologic time which, until recently, was not represented in the other martian meteorite types. The bulk rock 147 Sm/ 144 Nd value of 0.37 ± 0.02 is consistent with it being derived directly from its source and the high initial ε 143 Nd value indicates this source was geochemically highly depleted. Cr, Nd, and W isotopic compositions further support a unique mantle source. While the rock shares similarities with the 2.4-Ga NWA 7635 meteorite, there are notable distinctions between the two meteorites that suggest differences in mantle source compositions and conditions of crystallization. Nevertheless, the two samples may be launch-paired. Finally, NWA 8159 expands the known basalt types, ages and mantle sources within the Mars sample suite to include a second igneous unit from the early Amazonian.

58 GEOSCIENCES↗

Analysis of a Uranium Oxide Sample Interdicted in Slovakia (FSC 12-3-1)

We provide a concise summary of analyses of a natural uranium sample seized in Slovakia in November 2007. Results are presented for compound identification, water content, U assay, trace element abundances, trace organic compounds, isotope compositions for U, Pb, Sr and O, and age determination using the 234 U – 230 Th and 235 U – 231 Pa chronometers. The sample is a mixture of two common uranium compounds - schoepite and uraninite. The uranium isotope composition is indistinguishable from natural; 236 U was not detected. The O, Sr and Pb isotope compositions and trace element abundances are unremarkable. The 234 U – 230 Th chronometer gives an age of 15.5 years relative to the date of analysis, indicating the sample was produced in January 1997. A comparison of the data for this sample with data in the Uranium Sourcing database failed to find a match, indicating the sample was not produced at a facility represented in the database.

07 ISOTOPE AND RADIATION SOURCES↗

Colloid-Facilitated Radionuclide Transport in Fractured Carbonate Rock from Yucca Flat, Nevada National Security Site

In the Yucca Flat basin of the Nevada National Security Site (NNSS), ~750 nuclear detonations were conducted, primarily within the tuff confining unit (TCU) and the overlying alluvium. The regional carbonate aquifer (lower carbonate aquifer) is located below the TCU and is the most likely pathway for radionuclide migration off the NNSS. The regional carbonate aquifer underlies most of the NNSS and is known to be highly transmissive. Two principal pathways for LCA contamination exist in Yucca Flat. The first is composed of shortcuts (e.g. fractures) through the TCU which may provide a radionuclide transport pathway from tests conducted in the overlying alluvium and volcanics. The second is the release and migration of radionuclides from a small number (four) of tests conducted directly in the carbonate rock. Two of those tests were located near the saturated zone (Nash and Bourbon).

58 GEOSCIENCES↗

Nuclear Smuggling International Technical Working Group (ITWG): Round Robin #3 (Final Report)

Full nuclear forensics analysis of the two samples is complete. All uranium isotopic analyses indicate that both samples are weapons-usable, highly enriched uranium. Therefore, both seizures indicate that the statutes of the country of Texmex regarding the transport of uranium materials have been violated (>1 gram, >1% enriched in U235). Isotopic analysis by multicollector inductively coupled plasma-mass spectrometry (MC-ICP-MS) indicates that the two samples (Sample A, Sample B) have isotopic compositions that differ outside analytical uncertainty (k=2). The model ages of the two samples (apparent time since last chemical separation of parent and daughter nuclides) also differ outside analytical uncertainty (k=2). These results would indicate that, even with all of the other similarities between the two samples, the two questioned samples originate from different source materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Draft SOP for Sample Matching using ICP-MS

The purpose of this standard operating procedure (SOP) is to provide an assay for testing the hypothesis that two samples are from the same sub-population, which can mean they came from the same batch, set of replicate batches, or the same process. The outcome is a likelihood ratio, which should be used in combination with prior odds to determine the posterior odds of the two samples coming from the same sub-population. Note that the term “match” is not used because it is imprecise in the context of determining the relationship between two samples. Under this SOP, inductively coupled plasma mass spectrometer (ICP-MS) is used to generate elemental composition data, which is used to test the hypothesis that two samples come from the same sub-population. ICP-MS is a highly sensitive bulk analysis method. The quantity of sample required is ultimately determined by the instrumentation used and the elements selected for generating ROC curves. This SOP specifies that greater than 5 mg of sample be used to enable accurate weights to be obtained for the sample in tared 3 mL Teflon vials. However, we have conducted preliminary assays with our instrumentation that suggest that sample quantity can be reduced to 50 micrograms if elemental abundances are normalized to total metal content (see Step 10). We use ICP-MS because it is the most sensitive method for determining the concentration of the largest number of elements. Other elemental analysis methods could be used to generate data for this test (e.g., ICP-OES), but specific tests would be necessary to work out the SOP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗