Engineering Papers⌕ Search

Engineering topics

Lin, S.

Publications and source records attributed to Lin, S..

At least 37 records · Page 2

Search for slow magnetic monopoles with the NOvA detector on the surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 95-day exposure of the NOvA experiment’s Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of 2 × 10 -14 cm -2 s -1 sr -1 at 90% C.L. for monopole speed 6 × 10 -4 < β < 5 × 10 -3 and mass greater than 5 × 10 8 GeV. Because of NOvA’s small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of neutrino-induced neutral-current coherent $π^0$ production in the NOvA near detector

The cross section of neutrino-induced neutral-current coherent $\pi^0$ production on a carbon-dominated target is measured in the NOvA near detector. This measurement uses a narrow-band neutrino beam with the average neutrino energy of 2.7\,GeV, xwhich is of interest to the ongoing and future long-baseline neutrino oscillation experiments. The measured, flux-averaged cross section is $\sigma = 14.0\pm0.9$\,(stat.)$\pm2.1$\,(syst.)$\times 10^{-40}$ $\text{cm}^2/$nucleus, consistent with model prediction. This result is the most precise measurement of neutral-current coherent $\pi^0$ production in the few-GeV neutrino energy region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for multimessenger signals in NOvA coincident with LIGO/Virgo detections

Using the NOvA neutrino detectors, a broad search has been performed for any signal coincident with 28 gravitational wave events detected by the LIGO/Virgo Collaboration between September 2015 and July 2019. For all of these events, NOvA is sensitive to possible arrival of neutrinos and cosmic rays of GeV and higher energies. For five (seven) events in the NOvA Far (Near) Detector, timely public alerts from the LIGO/Virgo Collaboration allowed recording of MeV-scale events. No signal candidates were found.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adjusting neutrino interaction models and evaluating uncertainties using NOvA near detector data

The two-detector design of the NOvA neutrino oscillation experiment, in which two functionally identical detectors are exposed to an intense neutrino beam, aids in canceling leading order effects of cross-section uncertainties. However, limited knowledge of neutrino interaction cross sections still gives rise to some of the largest systematic uncertainties in current oscillation measurements. We show contemporary models of neutrino interactions to be discrepant with data from NOvA, consistent with discrepancies seen in other experiments. Adjustments to neutrino interaction models in GENIE are presented, creating an effective model that improves agreement with our data. We also describe systematic uncertainties on these models, including uncertainties on multi-nucleon interactions from a newly developed procedure using NOvA near detector data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of seasonal variation of atmospheric multiple-muon events in the NOvA Near Detector

Using two years of data from the NOvA Near Detector at Fermilab, we report a seasonal variation of cosmic ray induced multiple-muon (Nμ≥2) event rates which has an opposite phase to the seasonal variation in the atmospheric temperature. The strength of the seasonal multiple-muon variation is shown to increase as a function of the muon multiplicity. However, no significant dependence of the strength of the seasonal variation of the multiple-muon variation is seen as a function of the muon zenith angle, or the spatial or angular separation between the correlated muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high precision calibration of the nonlinear energy response at Daya Bay

A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment’s antineutrino detectors is observed. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by γ calibration points from deployed and naturally occurring radioactive sources, the β spectrum from 12 B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. With this beind said, less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New constraints on oscillation parameters from {nu}e appearance and {nu}{mu} disappearance in the NOvA experiment

We present updated results from the NOvA experiment for v(mu) -> v(mu) and v(mu) -> v(e) oscillations from an exposure of 8.85 x 10(20) protons on target, which represents an increase of 46% compared to our previous publication. The results utilize significant improvements in both the simulations and analysis of the data. A joint fit to the data for v(mu) disappearance and v(e) appearance gives the best-fit point as normal mass hierarchy, Delta m(32)(2) = 2.44 x 10(-3) eV(2)/c(4), sin(2) theta(23) = 0.56, and delta(CP) = 1.21 pi. The 68.3% confidence intervals in the normal mass hierarchy are Delta m(32)(2) is an element of[2.37, 2.52] x 10(-3) eV(2)/c(4) , sin(2) theta(23) is an element of [0.43; 0.51] boolean OR [0.52; 0.60], and delta(CP) is an element of [0, 0.21 pi] boolean OR [0.91 pi, 2 pi]. The inverted mass hierarchy is disfavored at the 95% confidence level for all choices of the other oscillation parameters.

Acero, M. A.↗

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

Here, the 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for active-sterile neutrino mixing using neutral-current interactions in NOvA

Here, we report results from the first search for sterile neutrinos mixing with active neutrinos through a reduction in the rate of neutral-current interactions over a baseline of 810 km between the NOvA detectors. Analyzing a 14-kton detector equivalent exposure of 6.05 × 10 20 protons-on-target in the NuMI beam at Fermilab, we observe 95 neutral-current candidates at the Far Detector compared with 83.5 ± 9.7(stat) ± 9.4(syst) events predicted assuming mixing only occurs between active neutrino species. No evidence for νμ→νs transitions is found. Interpreting these results within a 3+1 model, we place constraints on the mixing angles θ 24 < 20.8° and θ 34 < 31.2° at the 90% C.L. for 0.05 eV 2 ≤ Δm 41 2 ≤ 0.5 eV 2 , the range of mass splittings that produce no significant oscillations over the Near Detector baseline.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evolution of the Reactor Antineutrino Flux and Spectrum at Daya Bay

Here, the Daya Bay experiment has observed correlations between reactor core fuel evolution and changes in the reactor antineutrino flux and energy spectrum. Four antineutrino detectors in two experimental halls were used to identify 2.2 million inverse beta decays (IBDs) over 1230 days spanning multiple fuel cycles for each of six 2.9 GW th reactor cores at the Daya Bay and Ling Ao nuclear power plants. Using detector data spanning effective 239 Pu fission fractions F 239 from 0.25 to 0.35, Daya Bay measures an average IBD yield ¯σf of (5.90±0.13)×10 –43 cm 2 /fission and a fuel-dependent variation in the IBD yield, dσ f /dF 239 , of (–1.86±0.18)×10 –43 cm 2 /fission. This observation rejects the hypothesis of a constant antineutrino flux as a function of the 239 Pu fission fraction at 10 standard deviations. The variation in IBD yield is found to be energy dependent, rejecting the hypothesis of a constant antineutrino energy spectrum at 5.1 standard deviations. While measurements of the evolution in the IBD spectrum show general agreement with predictions from recent reactor models, the measured evolution in total IBD yield disagrees with recent predictions at 3.1σ. This discrepancy indicates that an overall deficit in the measured flux with respect to predictions does not result from equal fractional deficits from the primary fission isotopes 235 U, 239 Pu, 238 U, and 241 Pu. Based on measured IBD yield variations, yields of (6.17±0.17) and (4.27±0.26)×10 –43 cm 2 /fission have been determined for the two dominant fission parent isotopes 235 U and 239 Pu. A 7.8% discrepancy between the observed and predicted 235 U yields suggests that this isotope may be the primary contributor to the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on oscillation parameters from v e appearance and v μ disappearance in NOvA

Results are reported from an improved measurement of ν μ → ν e transitions by the NOvA experiment. Using an exposure equivalent to 6.05 × 10 20 protons on target, 33 νe candidates are observed with a background of 8.2 ± 0.8 (syst.). In this paper, combined with the latest NOvA νμ disappearance data and external constraints from reactor experiments on sin 2 2θ 13 , the hypothesis of inverted mass hierarchy with θ 23 in the lower octant is disfavored at greater than 93% C.L. for all values of δ CP .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗