Engineering Papers⌕ Search

Engineering topics

Liedahl, D. A.

Publications and source records attributed to Liedahl, D. A..

Understanding the deficiency in inertial confinement fusion hohlraum x-ray flux predictions using experiments at the National Ignition Facility

The predicted implosion performance of deuterium-tritium fuel capsules in indirect-drive inertial confinement fusion experiments relies on precise calculations of the x-ray drive in laser-heated cavities (hohlraums). This requires accurate, spectrally dependent simulations of laser to x-ray conversion efficiencies and x-ray absorption losses to the hohlraum wall. A set of National Ignition Facility experiments have identified a cause for the long-standing hohlraum “drive deficit” as the overprediction of gold emission at ~2.5 keV in nonlocal thermodynamic equilibrium coronal plasma regions within the hohlraum. Finally, reducing the emission and absorption opacity in this spectral region by ~20% brings simulations into agreement with measured x-ray fluxes and spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission Lines of Fe xiv, Fe xv, and Fe xvi in the Extreme Ultraviolet Region 40–100 Å

We report on emission spectra of iron in the extreme ultraviolet recorded at an electron density of ~10 11 cm -3 on the Lawrence Livermore electron beam ion trap facility. We present a summary of the observed emission lines, including wavelengths and emission intensities, and present spectra of pure Fe xiv through Fe xvi emission derived from our measurements in the 40–100 Å wavelength range. We show that spectral models, especially the current version of CHIANTI v10.0, describe the M-shell emission from these three charge states of iron reasonably well, and we are able to verify several transitions in CHIANTI for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantifying electron temperature distributions from time-integrated x-ray emission spectra

K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. Here we present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of $1310^{+90}_{-70}$ eV with significant contributions from temperatures down to 200 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of ionization trends in a laboratory photoionized plasma experiment at Z

We report experimental and modeling results for the charge state distribution of laboratory photoionized neon plasmas in the first systematic study over nearly an order of magnitude range of ionization parameter ξ ∝ F/N e . The range of ξ is achieved by flexibility in the experimental platform to adjust either the x-ray drive flux F at the sample or the electron number density N e or both. Experimental measurements of photoionized plasma conditions over such a range of parameters enable a stringent test of atomic kinetics models used within codes that are applied to photoionized plasmas in the laboratory and astrophysics. From experimental transmission data, ion areal densities are extracted by spectroscopic analysis that is independent of atomic kinetics modeling. The measurements reveal the net result of the competition between photon-driven ionization and electron-driven recombination atomic processes as a function of ξ as it affects the charge state distribution. Results from radiation-hydrodynamics modeling calculations with detailed inline atomic kinetics modeling are compared with the experimental results. There is good agreement in the mean charge and overall qualitative similarities in the trends observed with ξ but significant quantitative differences in the fractional populations of individual ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗

Demonstration of Geometric Effects and Resonant Scattering in the X-Ray Spectra of High-Energy-Density Plasmas

In a plasma of sufficient size and density, photons emitted within the system have a probability of being reabsorbed and reemitted multiple times—a phenomenon known in astrophysics as resonant scattering. This effect alters the ratio of optically thick to optically thin lines, depending on the plasma geometry and viewing angle, and has significant implications for the spectra observed in a number of astrophysical scenarios, but has not previously been studied in a controlled laboratory plasma. In this work, we demonstrate the effect in the x-ray spectra emitted by cylindrical plasmas generated by high power laser irradiation, and the results confirm the geometrical interpretation of resonant scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress toward NIF opacity measurements

The opacities of iron and other mid-Z elements help to regulate the transport of energy in the sun. Recent experiments on the Sandia National Laboratories Z machine have shown large discrepancies between the measured and calculated opacities of iron at certain solar conditions. To replicate these opacity measurements a platform is being developed on the National Ignition Facility to measure the opacities of iron and other elements at the same conditions as in the Z experiments. The NIF platform consists of a hohlraum to heat the opacity sample to the desired conditions, a separate backlighter to radiograph the sample, and a spectrometer to give the spectrally resolved opacity. Not only must the opacity be measured but the temperature and density of the sample must also be accurately determined. This platform has now produced its first iron transmission measurements. Overall, these measurements will be presented along with plans for future measurements and details on how the measurements will be improved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence of restricted heat transport in National Ignition Facility Hohlraums

We present experimental evidence of restricted electron thermal conduction in the high-Z coronal plasma regions of laser-driven Hohlraums on the National Ignition Facility. Four separate measurements, three of which are direct observations of Hohlraum dynamics, corroborate this finding. (1) The velocity of the coronal plasma ablated and heated by the outer-cone laser beams is determined by time-dependent imaging of the gold plasma plume, or “bubble.” The velocities of the incoming plume (perpendicular to the Hohlraum axis) are consistent with high-fidelity 2D radiation-hydrodynamic simulations using flux-limited thermal electron conduction with a flux multiplier f = 0.03. Simulations using f = 0.15, which is very nearly classical Spitzer–Härm transport, predict plume velocities slower than measured. (2) Specific features in time-resolved images of the Hohlraum wall at an angle of 19° are also more consistent with f = 0.03 simulations compared to f = 0.15. (3) Spectroscopic tracers were added to the Hohlraum wall in the outer-beam bubble region. The ratios of hydrogen-like to helium-like line emission are sensitive to the electron temperature of the bubble. The hydrogen-like to helium-like ratios extracted from the time-integrated spectra of manganese and cobalt tracers from two observation angles are consistent with f = 0.03 and not with f = 0.15. (4) The time of peak capsule emission, or “bang time,” an integrated measurement, is also more consistent with f = 0.03 than with f = 0.15. Overall, while these findings do not identify the causes of restricted thermal conduction in Hohlraums, they motivate future experiments to test specific hypotheses and focus on model development in the regions of the plasma exhibiting restricted transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the oscillator strength of intercombination lines of helium-like V ions in a laser-produced-plasma

In this work, we present results of measurements of the oscillator strength of intercombination lines of He-like Vanadium ions in high energy density (HED) laser-produced-plasmas and compare them with the simulations from commonly used codes and data from the NIST database. Whilst not yet sufficiently accurate to constrain different trusted atomic-physics models for the particular system studied, our results are in agreement with the available data within experimental error bars, yet differ from cruder approximations of the oscillator strength used in certain atomic-kinetics packages, suggesting that this general method could be further extended to be used as a measurement of the oscillator strength of additional atomic transitions under the extreme conditions that are achieved in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous UV and X-ray Spectroscopy of the Seyfert 1 Galaxy NGC 5548. I: Physical Conditions in the UV Absorbers

We present new UV spectra of the nucleus of the Seyfert 1 galaxy NGC 5548, which we obtained with the Space Telescope Imaging Spectrograph at high spectral resolution, in conjunction with simultaneous Chandra X-ray Observatory spectra. Taking advantage of the low UV continuum and broad emission-line fluxes, we have determined that the deepest UV absorption component covers at least a portion of the inner, high-ionization narrow-line region (NLR). We find nonunity covering factors in the cores of several kinematic components, which increase the column density measurements of N V and C IV by factors of 1.2 to 1.9 over the full-covering case; however, the revised columns have only a minor effect on the parameters derived from our photoionization models. For the first time, we have simultaneous N V and C IV columns for component 1 (at -1040 km/s), and find that this component cannot be an X-ray warm absorber, contrary to our previous claim based on nonsimultaneous observations. We find that models of the absorbers based on solar abundances severely overpredict the O VI columns previously obtained with the Far Ultraviolet Spectrograph, and present arguments that this is not likely due to variability. However, models that include either enhanced nitrogen (twice solar) or dust, with strong depletion of carbon in either case, are successful in matching all of the observed ionic columns. These models result in substantially lower ionization parameters and total column densities compared to dust-free solar-abundance models, and produce little O VII or O VIII, indicating that none of the UV absorbers are X-ray warm absorbers.

Crenshaw, D. M.↗

Complex Resonance Absorption Structure in the X-Ray Spectrum of IRAS 13349+2438

The luminous infrared-loud quasar IRAS 13349+2438 was observed with the XMM - Newton Observatory as part of the Performance Verification program. The spectrum obtained by the Reflection Grating Spectrometer (RGS) exhibits broad (FWHM - 1400 km/s) absorption lines from highly ionized elements including hydrogen- and helium-like carbon, nitrogen, oxygen, and neon, and several iron L - shell ions (Fe XVII - XX). Also shown in the spectrum is the first astrophysical detection of a broad absorption feature around lambda = 16 - 17 A identified as an unresolved transition array (UTA) of 2p - 3d inner-shell absorption by iron M-shell ions in a much cooler medium; a feature that might be misidentified as an O VII edge when observed with moderate resolution spectrometers. No absorption edges are clearly detected in the spectrum. We demonstrate that the RGS spectrum of IRAS 13349+2438 exhibits absorption lines from two distinct regions, one of which is tentatively associated with the medium that produces the optical/UV reddening.

Sako, M.↗

X-Ray Line Spectroscopy of Massive X-Ray Binaries

Spectra from ASCA have provided the most, detailed view to date of the X-ray spectral properties of stellar winds in massive X-ray binaries. Using detailed atomic models that account for recombination cascade kinetics, we have reexamined archival data from Vela X-1 and Cen X-3 in the context of simple models of their wind geometries and velocity distributions. Our approach emphasizes apparent differential emission measure (DEM) distributions, and their dependence on orbital phase and wind parameters. A grid of theoretical DEM distributions is used to generate model spectra, which are compared to the data. We obtain good fits, and derive constraints oil the stellar wind parameters. We provide a summary of the method, and show that, even though the companion stars in Vela X-1 and Cen X-3 have comparable mass-loss rates, the winds in these two systems are dramatically different, in character.

Liedahl, D. A.↗

Emission Line Spectra from Low-Density Laboratory Plasmas

Using spectroscopic equipment optimized for laboratory astrophysics, we are performing systematic measurements of the line emission from astrophysically relevant ions in the wavelength band between 1 and 400 Angstroms important to X-ray missions such as Chandra, XMM, Astro-E, and EUVE. Obtained in a controlled laboratory setting at electron densities similar to those found in stellar coronae, the data are used to test spectral modeling codes for accuracy and completeness. Our effort includes the compilation of the iron L-shell emission lines from 6-18 Angstroms and the iron M-shell emission lines from 50-200 Angstroms. Many lines have been identified for the first time, and the fluxes from lines missing in the spectral modeling codes are assessed. Our measurements also assess the accuracy of line excitation calculations, including direct electron-impact excitation, dielectronic recombination, and resonance excitation. These measurements yield a calibration of specific diagnostic line ratios. Examples of our current measurements are given.

Beiersdorfer, P.↗

X-Ray Spectroscopic Laboratory Experiments In Support of the NASA X-Ray Astronomy Flight Program

During the 1997 performance period, our work focused on the L-shell X-ray emission from highly charged iron ions in the 10-18 A region. Details of our accomplishments in 1997 are presented in the following. We start by describing the laboratory measurements made and their impact on the X-ray flight program and conclude by an overview of new instrumental capabilities developed for uses in the coming year.

Kahn, Steven M.↗

DXS spectra of the 0.25 keV diffuse background

Data from the diffuse X-ray spectrometer (DXS) experiment, a Shuttle payload that flew in January 1993, were analyzed. The DXS measured spectra from the local hot bubble component of the diffuse X-ray background. The soft X-ray diffuse background spectra contain emission lines and emission-line blends, indicating that the source of the low latitude diffuse background is thermal (a hot phase of the interstellar medium). The measured spectra do not resemble the model spectra of cosmic abundance or depleted abundance coronal plasmas at any temperature in the range of 10(exp 5) K to 10(exp 7) K.

Sanders, W. T.↗