Engineering Papers⌕ Search

Engineering topics

Li, Z.

Publications and source records attributed to Li, Z..

At least 37 records · Page 2

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron tagging following atmospheric neutrino events in a water Cherenkov detector

We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218±9 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

197 MHz Waveguide Loaded Crabbing Cavity Design for the Electron-Ion Collider

The Electron-Ion Collider requires several crabbing sys-tems at both hadron storage ring and electron storage ring in order to reach the desired luminosity goal. The 197 MHz crabbing cavity system is one of the critical rf sys-tems of the collider. The crab cavity based on the rf-dipole design explores the option of waveguide load damping in suppressing the higher order modes and to meet the tight impedance specifications. The cavity is designed with compact dogbone waveguides with transi-tions to rectangular waveguides and waveguide loads. This paper presents the compact 197 MHz crab cavity design with waveguide damping and other ancillaries.

De Silva, S.U.↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Advanced Visualization of Silent Error Propagation in HPC Applications

Last year, we refactored the major components of the SpotSDC visualization platform and added a visualization component for fault tolerance boundary. Also, we designed a new analysis framework to understand an application resiliency with a significantly less amount of samples compared to previous approaches. We evaluated the visualization platform and analysis framework for multiple critical HPC computation kernels and collected evidence for the effectiveness of the method developed. We published the findings of our research in the IEEE Transactions on Visualization and Computer Graphics (TVCG), the top journal in visualization. Moreover, we submitted a new paper, "Understanding a Program's Resiliency Through Error Propagation," to the PPOPP 2021 conference.

97 MATHEMATICS AND COMPUTING↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

43 PARTICLE ACCELERATORS↗

Quenching of single-particle strengths in direct reactions

A discrepancy in the asymmetry dependence of spectroscopic factors extracted with different reaction probes calls into question whether the corresponding reaction models are properly understood. In this work, we present extracted spectroscopic factors from the Ar 46 , 34 ( p , d ) Ar 45 , 33 transfer reactions in inverse kinematics at a beam energy of 70 MeV/nucleon. The results are consistent with previous measurements of these reactions at a lower beam energy [Lee et al. , Phys. Rev. Lett. 104 , 112701 (2010) ], indicating that the transfer reaction is a reliable probe for the nuclear structure of exotic nuclei across a wide energy range. Results from a large body of transfer reaction measurements, ( p , p N ) measurements, and theoretical nuclear structure studies make a compelling case for much weaker asymmetry dependence than what is observed with single-nucleon knockout reactions on beryllium or carbon targets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Persistence of the Z = 28 shell gap in A = 75 isobars: Identification of a possible ( 1 / 2 – ) μ s isomer in Co 75 and β decay to Ni 75

Here, the evolution of shell structure around doubly magic exotic nuclei is of great interest in nuclear physics and astrophysics. In the ‘southwest’ region of 78 Ni, the development of deformation might trigger a major shift in our understanding of explosive nucleosynthesis. To this end, new spectroscopic information on key close-lying nuclei is very valuable. We intend to measure the isomeric and β decay of 75 Co, with one-proton and two-neutron holes relative to 78Ni, to access new nuclear structure information in 75 Co and its β-decay daughters 75 Ni and 74 Ni. The nucleus 75 Co is produced in relativistic in-flight fission reactions of 238 U at the Radioactive Ion Beam Factory in the RIKEN Nishina Center. Its isomeric and β decay are studied exploiting the BigRIPS and EURICA setups. We obtain partial β-decay spectra for 75 Ni and 74 Ni, and report a new isomeric transition in 75 Co. The energy [E γ = 1914(2)keV] and half-life [t 1/2 = 13(6) μs] of the delayed γ ray lend support for the existence of a J π = (1/2 – ) isomeric state at 1914(2) keV. A comparison with PFSDG-U shell-model calculations provides a good account for the observed states in 75 Ni, but the first calculated 1/2 – level in 75 Co, a prolate K = 1/2 state, is predicted about 1 MeV below the observed (1/2 – ) level. The spherical-like structure of the lowest-lying excited states in 75 Ni is proved. In the case of 75 Co, the results suggest that the dominance of the spherical configurations over the deformed ones might be stronger than expected below 78 Ni. Further experimental efforts to discern the nature of the J π = (1/2 – ) isomer are necessary.

59 ≤ A ≤ 89↗

HOM DAMPER DESIGN FOR BNL EIC 197MHZ CRAB CAVITY

For the electron Storage Ring (ESR) of Brookhaven Na-tional Lab Electron Ion Collider (BNL EIC), beam loading is a great concern due to the high beam current together with abortion gap, especially for harmonic cavities due to higher operational frequency. There were attempts to use feedback/feedforward control, using multiple cavities with counter-phasing [1]. A straightforward way to lower beam loading effect is to design a cavity with low R/Q. In this paper, we show such a design for the 3rd harmonic cavity for BNL EIC ESR.

43 PARTICLE ACCELERATORS↗