Engineering Papers⌕ Search

Engineering topics

Li, Yanfei

Publications and source records attributed to Li, Yanfei.

52 records · Page 3

Sensor Impact Evaluation at Different Sensor Locations in a Multi-zone Office Building

FY 2022 Q1 deliverables include the development of an emulator that can evaluate the sensor impacts at different sensor locations (i.e., thermostat locations) in a multizone office building. This report presents the detailed procedure of developing the emulator and using the emulator for preliminary sensor impact analysis. In designing new multizone buildings or retrofitting existing buildings, the room thermostat locations or subzoning design has been often determined by best practices without considering the effects of this design in terms of energy or thermal comfort. In subzoning design, the total number of thermostats is usually smaller than the total number of rooms. As a result, one thermostat in one room often controls the indoor temperature of several other adjacent rooms. For example, five zones might share one thermostat located in one of the zones. Because the demands for thermal load in different zones could be different for the multizone buildings, this subzoning design can compromise control performance and waste building energy consumption. Furthermore, for multizone buildings, subzoning could introduce thermal discomfort for zones. This issue has not be thoroughly investigated in simulation/field studies, and the US Department of Energy’s Oak Ridge National Laboratory explored the impacts of subzoning design through modeling and experimental study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor impacts on building and HVAC controls: A critical review for building energy performance

Building operations rely heavily on control systems and sensors. This paper provides a sophisticated literature review on sensor systems in building/HVAC systems, particularly in the context of controls, and their impacts on energy efficiency and thermal comfort. This study aims to understand the previous and current research and identify future research opportunities on this subject. The reviewed sensor systems were used for heuristic rule-based controls, local controls, and advanced optimal controls for existing and emerging technologies. Five major aspects of sensors are reviewed here: control loops for sensors, sensor types, sensor locations, sensor data, and a sensor impact evaluation framework. To augment the literature review, comprehensive standardized interviews were also conducted with relevant industry experts and practitioners. These interviews were designed and performed to (1) identify significant factors for selecting sensor sets and current undergoing issues, (2) identify potential improvements in sensor configuration/deployment, and (3) integrate expert (e.g., researcher, building operation practitioner) knowledge and experiences to develop structured use-case scenarios. Researchers collected and analyzed 31 interview responses for this paper.

Building control↗

Probing Charge Dynamics in Diamond with an Individual Color Center

Control over the charge states of color centers in solids is necessary to fully utilize them in quantum technologies. However, the microscopic charge dynamics of deep defects in wide-band-gap semiconductors are complex, and much remains unknown. We utilize a single-shot charge-state readout of an individual nitrogen-vacancy (NV) center to probe the charge dynamics of the surrounding defects in diamond. We show that the NV center charge state can be converted through the capture of holes produced by optical illumination of defects many micrometers away. With this method, we study the optical charge conversion of silicon-vacancy (SiV) centers and provide evidence that the dark state of the SiV center under optical illumination is SiV 2– . These measurements illustrate that charge carrier generation, transport, and capture are important considerations in the design and implementation of quantum devices with color centers and provide a novel way to probe and control charge dynamics in diamond.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of machine learning in building load prediction

The surge of machine learning in recent years has been empowering engineer modeling in various fields. The decreasing hardware cost, increasing data accessibility, and advances of building automation system (BAS) allow the collection and storage of a significant amount of building operation data. The two facts provide great opportunities of applying machine learning to building energy systems modeling and analysis. There are a great number of research papers on this topic but there lacks a comprehensive and general review to summarize the current development, limitations, gaps and future trend. In this review paper series, machine learning techniques in building energy system modeling and analysis are reviewed under the organization and logic of the machine learning definition by Tom M. Mitchell: a computer program is said to learn from experience E with respect to some class of tasks T and performance measure P if its performance at tasks in T, as measured by P, improves with experience E. This paper is the first part of the review paper series, which focuses on building load prediction. First, the applications of building load prediction model (task T) are reviewed. Then, the modeling algorithms improving machine learning performance and accuracy (performance P) are reviewed. At the same time, the literature on the data perspective for modeling (experience E), including data engineering from sensors level to data level, pre-processing, feature extraction and selection, is reviewed. Finally, what is well-studied and what is lacking but with great potential are concluded; the gaps between present and future utilization of machine learning techniques are identified; the future trend and development are also predicted. The target readers of this paper are not only researchers from the building side who can get exposed to cutting edge machine learning tools, but also those from machine learning side who can understand the potential and challenge to apply machine learning in buildings.

Liang, Zhang↗

O3BNN-R: An Out-Of-Order Architecture for High-Performance and Regularized BNN Inference

Binarized Neural Networks (BNN) have drawn tremendous attention due to significantly reduced computational complexity and memory demand. They have especially shown great potential in cost- and power-restricted domains, such as IoT and smart edge-devices, where reaching a certain accuracy bar is often sufficient, and real-time is highly desired.In this work, we demonstrate that the highly-condensed BNN model can be shrunk significantly further by dynamically pruning irregular redundant edges. Based on two new observations on BNN-specific properties, an out-of-order (OoO) architecture – O3BNN-R, can curtail edge evaluation in cases where the binary output of a neuron can be determined early. Similar to Instruction-Level-Parallelism(ILP), these fine-grained, irregular, runtime pruning opportunities are traditionally presumed to be difficult to exploit. In order to increase the pruning opportunities, we also optimize the training process by adding 2 regularization items in the loss function (1) for pooling pruning and (2) for threshold pruning. We evaluate our design on an FPGA platform using three well-known networks, including VggNet-16, AlexNet for ImageNet, and a VGG-like network for Cifar-10.

Geng, Tong↗

AWB-GCN: A Graph Convolutional Network Accelerator with Runtime Workload Rebalancing

The recent development of deep learning has been mostly focusing on Euclidean data, such as images, videos, audios, etc. However, most real-world information and relation are often expressed as graphs. To efficiently learn from graph data, graph convolutional networks (GCNs) emerge as a promising approach, showing advantages in several practical applications such as social network analysis, knowledge discovery, 3D modeling, motion capturing, etc. Real-world graphs are usually extremely large and imbalanced, posting significant performance demand and design challenges on the hardware dedicated for GCN inference. In this paper, we propose an architecture design called UW-GCN to accelerate graph convolutional network inference. To tackle the major performance bottleneck from workload imbalance, we propose dynamic neighborhood stealing and remote chunk shuffling techniques, relying on hardware flexibility to achieve hardware auto-tuning under negligible area or delay overhead. Specifically, UW-GCN is able to smartly profile the sparse graph pattern while continuously adjusting the workload distribution via routing reconfiguration among parallel processing elements (PEs). The ideal configuration is then reused in the remaining iterations. To the best of our knowledge, this is the first accelerator design particularly for GCN and the first work relying on hardware auto-tuning, which is normally based on software, to achieve near-optimal workload balance in processing sparse structures.

Geng, Tong↗

Spawn [SWR-SWR-20-10]

Spawn is a next generation building simulation engine designed to build on the strengths of NREL's venerable EnergyPlus engine, and add new advanced HVAC and controls modeling capability by incorporating the Modelica equation based modeling language. In effect, Spawn is a hybrid of the existing EnergyPlus and Modelica software products, with some new software to provide glue between the components in order to provide a seamless end user experience.

Li, Yanfei↗

A Novel Simulation-Based Framework for Sensor Error Impact Analysis in Smart Building Systems: A Case Study for a Demand-Controlled Ventilation System

Sensors are one of the fundamental components for sensor-rich controls in buildings but are prone to different errors. Existing studies show that sensor errors hold a place among top-priority faults in building systems. Before we take countermeasures to mitigate the sensor errors, it is vital to prioritize key sensors and quantify the collective impacts of concurrent sensor errors. In response to this, a simulation-based methodology is introduced to conduct a comprehensive sensor error impact analysis in building systems, which adds a stochastic sensor prioritization through a sensitivity analysis on top of a commonly used deterministic sensor error quantification. The synergies of these two parts help better interpret the sensor error impacts on building energy consumption, ventilation performance, thermal comfort, etc. A sensor-rich CO2-based Demand-Controlled Ventilation system is used as a case study to demonstrate the viability of the methodology as a proof-of-the-concept. The results show that the energy savings potential and ventilation performance are mostly influenced by the accuracy of the AHU outdoor airflow sensors. The accuracy of zone level airflow sensors has a negligible impact on both energy savings and ventilation performance. The accuracy of zone CO2 sensors has more influence on the ventilation performance compared with the accuracy of zone airflow sensors. Compared with the baseline case with zero errors, the largest deviation percentages could reach 16.90% and 94.32%, respectively, in terms of the Heating, Ventilation, and Air-Conditioning (HVAC) annual energy consumption and the Outdoor Air Ratio (OAR) when multiple key sensors suffer from normal error intensities simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Role of Sensitivity Analysis in the Building Performance Analysis: A Critical Review

A building system is highly nonlinear and commonly includes a variety of parameters ranging from the architectural design to the building mechanical and energy system. Serving as a powerful tool to understand the complicated building system, sensitivity analysis (SA) has been receiving increasing attention in the recent decade. This review paper focused on the application of SA in the building performance analysis (BPA). First, the existing review papers on the application of SA for BPA were briefly reviewed and summarized. Then, a large amount of recent SA case studies in BPA were reviewed. The critical information regarding the implementation of a SA, such as the sampling method, the SA method, etc., were extracted and summarized. Next, an extensive analysis was performed to evaluate the role of the SA in the BPA. This includes: 1) The typical selection of the input and output parameters for the SA were visualized; 2) The uncertainty level and sampling strategies for the input parameters were investigated; 3) The principles, benefits, and drawbacks of the SA methods were analyzed and summarized; and 4) The various tools used in the SA, including the simulation software, sampling tools, and SA tools were introduced to facilitate the practitioners. Lastly, several conclusions were summarized on the role of the SA in the BPA. Suggestions were also provided to offer practical solutions to the current challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Innovative Fault Impact Analysis Framework for Enhancing Building Operations

The main goal of this paper is to rank building faults based on their impacts on the building energy penalty and occupant thermal comfort penalty considering multiple faults and fault occurrence rates. A fault impact analysis framework is created by incorporating the fault model library with the whole building energy performance simulation (e.g., EnergyPlus used in this study). The fault occurrence rate is introduced as a 'meta' parameter in the simulation. This framework involves three essential aspects of conducting a fault impact analysis: fault constructing, fault simulation, and fault impact analysis. A parametric sensitivity analysis was used to determine and rank the criticality of the faults considering the fault concurrence frequency, by using the deep-learning based response surface model (i.e., the multi-layer perceptron regression). The proposed fault analysis framework with ranking was tested and demonstrated for the DOE's prototype medium-sized office in four different climate zones (i.e., Atlanta, Chicago, Miami, and San Francisco) with 12,000 EnergyPlus fault simulations. A total of 129 fault modes from 41 groups of fault models were simulated for the medium-sized office case. The results demonstrate the proposed framework is robust and scalable for the fault impact analysis. The top critical fault for the medium-sized office is the fault of HVAC-Left-ON for the packaged rooftop unit, regarding the site energy, source energy, and HVAC energy. Excluding the fault of HVAC-Left-ON, the top critical faults vary significantly among the four climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototyping the BOPTEST Framework for Simulation-Based Testing of Advanced Control Strategies in Buildings

Advanced control strategies are becoming increasingly necessary in buildings in order to meet and balance requirements for energy efficiency, demand flexibility, and occupant comfort. Additional development and widespread adoption of emerging control strategies, however, ultimately require low implementation costs to reduce payback period and verified performance to gain control vendor, building owner, and operator trust. This is difficult in an already first-cost driven and risk-averse industry. Recent innovations in building simulation can significantly aid in meeting these requirements and spurring innovation at early stages of development by evaluating performance, comparing state-of-the-art to new strategies, providing installation experience, and testing controller implementations. This paper presents the development of a simulation framework consisting of test cases and software platform for the testing of advanced control strategies (BOPTEST - Building Optimization Performance Test). The objectives and requirements of the framework, components of a test case, and proposed software platform architecture are described, and the framework is demonstrated with a prototype implementation and example test case.

Blum, David↗

Development of control quality factor for HVAC control loop performance assessment—II: Field testing and results (ASHRAE RP-1587)

This article is the third paper from the research project RP-1587, focusing on presenting a comprehensive field test of the proposed control quality factors (CQFs; i.e., CQF-Harris and CQF-exponentially weighted moving average [EWMA]) and testing results. Firstly, the simulated control loops and real control loops are evaluated for offline assessment. Then, the field experiment implemented for different HVAC control loops is assessed online using the proposed CQFs. Test results show that the proposed CQFs are capable of adequately and effectively assessing the HVAC control loop performance. The methodology of obtaining those CQFs is provided in the companion paper: Development of Control Quality Factor for HVAC Control Loop Performance Assessment I - Methodology (ASHRAE RP-1587) (Li et al. 2019 Li, Y., Z. D. O'Neill, and X. Zhou. 2019. Development of control quality factor for HVAC control loop performance assessment I - Methodology (ASHRAE RP-1587).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of control quality factor for HVAC control loop performance assessment I—Methodology (ASHRAE RP-1587)

This article is the second paper from the ASHRAE research project RP-1587, focusing on the methodology of obtaining a control quality factor (CQF). This article presents a development of two CQFs for assessing the heating, ventilation, and air-conditioning (HVAC) control loop performance. Both CQFs are able to detect whether the control loop is able to maintain the setpoint and identify the loop's ability to handle disturbances. In addition, the reversal behaviors are assessed as well. The first CQF (CQF-Harris) is proposed based on the normalized Harris index using the recursive least squares method. This recursive least squares method is selected because of its computational efficiency compared with the maximum likelihood estimation method. The second CQF (CQF-EWMA) is based on the exponentially weighted moving average of the error ratio. The assessment scale of excellent, good, fair, bad, and failed, which indicates the quality of the HVAC control loops, is established as well. The sensitivity analysis for both CQFs is also conducted, and it provides insights on choosing the appropriate parameters to compute such CQFs. Such parameters include the sampling frequency, the length of the moving window, and the variance of the unmeasured disturbance. The field evaluations and tests of the proposed CQFs for simulated control loops and real control loops can be found in the companion paper with the title 'Development of Control Quality Factor for HVAC Control Loop Performance Assessment - III: Field Testing and Results (ASHRAE RP-1587).'

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗