Engineering Papers⌕ Search

Engineering topics

Li, Ke

Publications and source records attributed to Li, Ke.

At least 37 records · Page 2

Intercalation-Induced Reversible Electrochromic Behavior of Two-Dimensional Ti 3 C 2 T x MXene in Organic Electrolytes

MXenes, a large family of two-dimensional materials, have attracted tremendous attention due to their unique physical and chemical properties. Reversible ion intercalation between MXene layers allows modification of the optical, thermal, magnetic, and chemical properties. The electrochemical charge/discharge of MXenes in aqueous electrolytes was reported to lead to reversible electrochromic behavior. In this work, the electrochromic effect of semitransparent Ti 3 C 2 T x MXene film was probed by electrochemical intercalation of Li ions. Correspondingly, a peak shift of 100 nm was observed in the UV-vis spectrum. By combining in-situ Raman spectroscopy, in-situ X-ray diffraction, and density functional theory calculations, we show that the electrochromic shift is primarily due to the formation of robust O-Li bonds and the emerging bands induced changes of inter-band excitations. Finally, understanding the mechanism of electrochromic behavior in Ti 3 C 2 T x lays the foundations of designating 2D materials with durable, controllable, and efficient intercalation-induced electrochromic behaviors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Demonstration of a Class 6 Range-Extended Electric Vehicle for Commercial Pickup and Delivery Operation: Preprint

Range-extended hybrids are an attractive option for medium- and heavy-duty commercial vehicle fleets because they offer the efficiency of an electrified powertrain with the driving range of a conventional diesel powertrain. The vehicle essentially operates as if it was purely electric for most trips, while ensuring that all commercial routes can be completed in any weather conditions or geographic terrain. Fuel use and point-source emissions can be significantly reduced, and in some cases eliminated, as many shorter routes can be fully electrified with this architecture. Under a U.S. Department of Energy (DOE)-funded project for Medium- and Heavy-Duty Vehicle Powertrain Electrification, Cummins has developed a plug-in hybrid electric Class 6 truck with a range-extending engine designed for pickup and delivery application. The National Renewable Energy Laboratory (NREL) assisted by developing representative workday drive cycles for Class 6 operation and an adapted cycle to enable vehicle track testing. A novel, automated driving system was utilized by Southwest Research Institute (SwRI) to improve the repeatability of the track testing conducted to quantify vehicle energy consumption. Cummins used a drivetrain model to design the hybrid control system for increased fuel savings. The control system functionality and fuel savings objective of 50% or more were confirmed by track testing described in this paper.

ADVANCED PROPULSION SYSTEMS↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Influences from solvents on charge storage in titanium carbide MXenes

We report that pseudocapacitive energy storage in supercapacitor electrodes differs significantly from the electrical double-layer mechanism of porous carbon materials, which requires a change from conventional thinking when choosing appropriate electrolytes. Here we show how simply changing the solvent of an electrolyte system can drastically influence the pseudocapacitive charge storage of the two-dimensional titanium carbide, Ti 3 C 2 (a representative member of the MXene family). Measurements of the charge stored by Ti 3 C 2 in lithium-containing electrolytes with nitrile-, carbonate- and sulfoxide-based solvents show that the use of a carbonate solvent doubles the charge stored by Ti 3 C 2 when compared with the other solvent systems. We find that the chemical nature of the electrolyte solvent has a profound effect on the arrangement of molecules/ions in Ti 3 C 2 , which correlates directly to the total charge being stored. Finally, having nearly completely desolvated lithium ions in Ti 3 C 2 for the carbonate-based electrolyte leads to high volumetric capacitance at high charge–discharge rates, demonstrating the importance of considering all aspects of an electrochemical system during development.

25 ENERGY STORAGE↗

Ionic conductivity and counterion condensation in nanoconfined polycation and polyanion brushes prepared from block copolymer templates

Microphase separated block copolymer electrolyte (BCE) systems are attractive candidates for electrochemical systems because the concentrated ionic groups in one block provide pathways for facile ion transport while the non-ionic block bestows mechanical integrity and suppresses excess water uptake. Numerous researchers have prepared and studied bulk BCEs as ion conductors, but these materials inherent complex nature and imprecise architecture makes it difficult to extract definitive conclusions how the macromolecular structure influences ion transport. In this work, the process of block copolymer lithography was demonstrated to create model nano-confined polymer electrolyte brushes that mimic lamellae structures found in bulk BCE membranes. Both nano-confined anion and cation conducting polymer brushes were prepared and excellent ionic conductivities (10 -2 S cm -1 to 10 -1 S cm -1 ) were obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-low-dose limited renal CT for volumetric stone surveillance: advantages over standard unenhanced CT

Purpose: To describe and validate a novel CT approach using volumetric analysis for renal stone surveillance. Materials and methods: This prospective trial consisted of a standard low-dose non-contrast CT (SLD) of the abdomen and pelvis, immediately followed by an ultra-low-dose non-contrast CT (ULD) with reconstruction limited to the kidneys. A novel dedicated software tool was applied that automates stone volume, density, and maximum linear size. Manual linear stone size was measured by a radiology fellow and urology resident for comparison. CT dose and clinical charges were considered. Results: Twenty-eight stones in 16 patients were analyzed. Mean effective dose of ULD CT was 0.57 mSv, an average 92% lower than the SLD CT dose. For SLD, mean size ± SD (range) (mm) was 7.9 ± 6.2 (2.6–30.5) for Reader 1, 7.3 ± 6 (2.4–30.7) for Reader 2, and 9.3 ± 6.4 (3.7–33.1) for the automated software. For ULD, mean size ± SD (range) (mm) was 7.3 ± 6 (2.5–30.5) for Reader 1, 7.2 ± 6.1 (2.1–30.7) for Reader 2, and 9.1 ± 6.4 (4.2–32.8) for the automated software. Automated stone diameters were larger than manual diameters for 27/28 stones (mean difference, 23%); difference was ≥ 2 mm in 30%. Average variability between manual measurements was 8.6% (SLD) and 7.8% (ULD), but was 0% for the automated technique. Our institutional charge for ULD renal CT is slightly less than renal US, and > 4× less than SLD CT. The Medicare global fee for the ULD renal CT is less than the SLD CT of the abdomen and pelvis. Conclusions: This focused stone surveillance CT protocol is lower cost and lower dose compared to the standard CT approach. Automated assessment of stone burden provides improved reproducibility over manual linear measurement and offers the advantages of 3D measurements and volumetry. We now offer and perform this protocol in routine clinical practice for stone surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination of DESI2 and endostatin gene therapy significantly improves antitumor efficacy by accumulating DNA lesions, inducing apoptosis and inhibiting angiogenesis

Highlights: • Combination of DESI2 with endostatin could improve the therapy efficacy in vitro and in vivo. • The combination of DESI2 with endostatin causes DNA lesions accumulation. • The improved antitumor effect was associated with inhibition of cell proliferation via apoptosis. • The enhanced antitumor effect also partially resulted from inhibition of angiogenesis. DESI2 is a novel pro-apoptotic gene. We previously reported that DESI2 overexpression induces S phase arrest and apoptosis by activating checkpoint kinases. This work was to test whether the combination of endostatin, an endogenous antiangiogenic inhibitor, with DESI2 could improve the therapy efficacy in vitro and in vivo. The recombinant plasmid co-expressing DESI2 and endostatin was encapsulated with DOTAP/Cholesterol cationic liposome. Mice bearing CT26 colon carcinoma and LL2 lung cancer were treated with the DNA-liposome complex. We found that, in vitro, the combination of DESI2 and endostatin more efficiently inhibited proliferation of CT26, LL2, HCT116 and A549 cancer cells via apoptosis, as assessed by MTT assay, colony-formation assays, flow cytometric analysis, hoechst staining and activation of caspase-3, respectively. In addition, DESI2 overexpression caused up-regulation of RPS7, a substrate of DESI2 deubiquitination. Furthermore, siRNA targeting RPS7 partially abrogated, whereas RPS7 overexpression enhanced DESI2-induced inhibition of cell proliferation. Importantly, the combination also caused DNA lesions accumulation, which further promotes apoptosis. Mechanistic rationale suggested that endostatin first inhibits DNA-PKcs kinase, and partly abrogated DESI2-induced phosphorylation of DNA-PKcs, leading to increase of DNA damage, then contributes to DESI2-induced apoptosis. In vivo, the combined gene therapy more significantly inhibited tumor growth and efficiently prolonged the survival of tumor bearing mice than mono therapy. The improved antitumor effect was associated with inhibition of cell proliferation via apoptosis, as analyzed by TUNEL assay and PCNA immunostaining. The combination also inhibited angiogenesis, as assessed by alginate-encapsulated tumor cell assay and CD31 staining. Our data suggest that the combined gene therapy of DESI2 and endostatin can significantly enhance the antitumor activity as a DNA lesions accumulator, apoptosis inducer and angiogenesis inhibitor. The present study may provide a novel method for the treatment of cancer.

60 APPLIED LIFE SCIENCES↗

ATM inhibition induces synthetic lethality and enhances sensitivity of PTEN-deficient breast cancer cells to cisplatin

Highlights: • ATM is a synthetically lethal target in breast cancer cells with PTEN defects. • ATM inhibitor KU-60019 preferentially sensitizes PTEN-deficient breast cancer cells to cisplatin. • The selective cytotoxicity results from the increase of DNA damage accumulation and the decreased capability of DNA repair. • PTEN-deficient MDA-MB-468 cells have lower level of Rad51, higher ATM kinase activity than PTEN wild-type MDA-MB-231 cells. PTEN deficiency often causes defects in DNA damage repair. Currently, effective therapies for breast cancer are lacking. ATM is an attractive target for cancer treatment. Previous studies suggested a synthetic lethality between PTEN and PARP. However, the synthetically lethal interaction between PTEN and ATM in breast cancer has not been reported. Moreover, the mechanism remains elusive. Here, using KU-60019, an ATM kinase inhibitor, we investigated ATM inhibition as a synthetically lethal strategy to target breast cancer cells with PTEN defects. We found that KU-60019 preferentially sensitizes PTEN-deficient MDA-MB-468 breast cancer cells to cisplatin, though it also slightly enhances sensitivity of PTEN wild-type breast cancer cells. The increased cytotoxic sensitivity is associated with apoptosis, as evidenced by flow cytometry and PARP cleavage. Additionally, the increase of DNA damage accumulation due to the decreased capability of DNA repair, as indicated by γ-H2AX and Rad51 foci, also contributed to this selective cytotoxicity. Mechanistically, compared with PTEN wild-type MDA-MB-231 cells, PTEN-deficient MDA-MB-468 cells have lower level of Rad51, higher ATM kinase activity, and display the elevated level of DNA damage. Moreover, these differences could be further enlarged by cisplatin. Our findings suggest that ATM is a promising target for PTEN-defective breast cancer.

60 APPLIED LIFE SCIENCES↗

Development of 80- and 100- Mile Work Day Cycles Representative of Commercial Pickup and Delivery Operation

When developing and designing new technology for integrated vehicle systems deployment, standard cycles have long existed for chassis dynamometer testing and tuning of the powertrain. However, to this day with recent developments and advancements in plug-in hybrid and battery electric vehicle technology, no true 'work day' cycles exist with which to tune and measure energy storage control and thermal management systems. To address these issues and in support of development of a range-extended pickup and delivery Class 6 commercial vehicle, researchers at the National Renewable Energy Laboratory in collaboration with Cummins analyzed 78,000 days of operational data captured from more than 260 vehicles operating across the United States to characterize the typical daily performance requirements associated with Class 6 commercial pickup and delivery operation. In total, over 2.5 million miles of real-world vehicle operation were condensed into a pair of duty cycles, an 80-mile cycle and a 100-mile cycle representative of the daily operation of U.S. class 3-6 commercial pickup and delivery trucks. Using novel machine learning clustering methods combined with mileage-based weighting, these composite representative cycles correspond to 90th and 95th percentiles for daily vehicle miles traveled by the vehicles observed. In addition to including vehicle speed vs time drive cycles, in an effort to better represent the environmental factors encountered by pickup and delivery vehicles operating across the United States, a nationally representative grade profile and key status information were also appended to the speed vs. time profiles to produce a 'work day' cycle that captures the effects of vehicle dynamics, geography, and driver behavior which can be used for future design, development, and validation of technology.

100 mile↗