FAULT PROPAGATION AND EFFECTS ANALYSIS FOR DESIGNING AN ONLINE MONITORING SYSTEM FOR THE SECONDARY LOOP OF A NUCLEAR POWER PLANT PART OF A HYBRID ENERGY SYSTEM

This paper studies the propagation and effects of faults of critical components that pertain to the secondary loop of a nuclear power plant found in Nuclear Hybrid Energy Systems (NHES). This information is used to design an on-line monitoring (OLM) system which is capable of detecting and forecasting faults that are likely to occur during NHES operation. In this research, the causes, features, and effects of possible faults are investigated by simulating the propagation of faults in the secondary loop. The simulation is accomplished by using the Integrated System Failure Analysis (ISFA). ISFA is used for analyzing hardware and software faults during the conceptual design phase. In this paper, the models of system components required by ISFA are initially constructed. Then, the fault propagation analysis is implemented, which is conducted under the bounds set by acceptance criteria derived from the design of an OLM system. The result of the fault simulation is utilized to build a database for fault detection and diagnosis, provide preventive measures, and propose an optimization plan for the OLM system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methods to Determine Recommended Feeder-Wide Advanced Inverter Settings for Improving Distribution System Performance

This paper describes methods that a distribution engineer could use to determine advanced inverter settings to improve distribution system performance. These settings are for fixed power factor, volt-var, and volt-watt functionality. Depending on the level of detail that is desired, different methods are proposed to determine single settings applicable for all advanced inverters on a feeder or unique settings for each individual inverter. Seven distinctly different utility distribution feeders are analyzed to simulate the potential benefit in terms of hosting capacity, system losses, and reactive power attained with each method to determine the advanced inverter settings.

14 SOLAR ENERGY↗

Failure Diagnosis for the Holdup Tank System via ISFA

This paper discusses the use of the integrated system failure analysis (ISFA) technique for fault diagnosis for the holdup tank system. ISFA is a simulation-based, qualitative and integrated approach used to study fault propagation in systems containing both hardware and software subsystems. The holdup tank system consists of a tank containing a fluid whose level is controlled by an inlet valve and an outlet valve. We introduce the component and functional models of the system, quantify the main parameters and simulate possible failure-propagation paths based on the fault propagation approach, ISFA. The results show that most component failures in the holdup tank system can be identified clearly and that ISFA is viable as a technique for fault diagnosis. Since ISFA is a qualitative technique that can be used in the very early stages of system design, this case study provides indications that it can be used early to study design aspects that relate to robustness and fault tolerance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Failure Diagnosis for the Holdup Tank System via ISFA

This paper discusses the use of the integrated system failure analysis (ISFA) technique for fault diagnosis for the holdup tank system. ISFA is a simulation-based, qualitative and integrated approach used to study fault propagation in systems containing both hardware and software subsystems. The holdup tank system consists of a tank containing a fluid whose level is controlled by an inlet valve and an outlet valve. We introduce the component and functional models of the system, quantify the main parameters and simulate possible failure-propagation paths based on the fault propagation approach, ISFA. The results show that most component failures in the holdup tank system can be identified clearly and that ISFA is viable as a technique for fault diagnosis. Since ISFA is a qualitative technique that can be used in the very early stages of system design, this case study provides indications that it can be used early to study design aspects that relate to robustness and fault tolerance. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report Report: Smart Grid Ready PV Inverters with Utility Communication

In 2011, EPRI began a four-year effort under the Department of Energy (DOE) SunShot Initiative Solar Energy Grid Integration Systems - Advanced Concepts (SEGIS-AC) to demonstrate smart grid ready inverters with utility communication. The objective of the project was to successfully implement and demonstrate effective utilization of inverters with grid support functionality to capture the full value of distributed photovoltaic (PV). The project leveraged ongoing investments and expanded PV inverter capabilities, to enable grid operators to better utilize these grid assets. Developing and implementing key elements of PV inverter grid support capabilities will increase the distribution system’s capacity for higher penetration levels of PV, while reducing the cost. The project team included EPRI, Yaskawa-Solectria Solar, Spirae, BPL Global, DTE Energy, National Grid, Pepco, EDD, NPPT and NREL. The project was divided into three phases: development, deployment, and demonstration. Within each phase, the key areas included: head-end communications for Distributed Energy Resources (DER) at the utility operations center; methods for coordinating DER with existing distribution equipment; back-end PV plant master controller; and inverters with smart-grid functionality. Four demonstration sites were chosen in three regions of the United States with different types of utility operating systems and implementations of utility-scale PV inverters. This report summarizes the project and findings from field demonstration at three utility sites.

14 SOLAR ENERGY↗

Wireless Communication for Controlling Microgrids: Co-simulation and Performance Evaluation

A microgrid with wireless communication links for microgrid control has been designed and developed. The complete simulation model has been developed in MatLab SimuLink with seamless integration of the power subsystem and the communication subsystem. Unlike the conventional co-simulators that usually glue two existing simulators together by creating an interface, which has a steep learning curve, the proposed simulator is a compact single-unit model. Detailed modeling of the power subsystem and communication system is presented as well as the microgrid control architecture and strategies. The impact of different communication system performances on microgrid control has been studied and evaluated in the proposed simulator.

Mao, Rukun↗

Real Power and Reactive Power Control of a Three-Phase Single-Stage-PV System and PV voltage Stability

Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous and Adaptive Voltage Control using Multiple Distributed Energy Resources

Voltage regulation using distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control has drawn increasing interests. This paper addresses the challenges of controlling multiple DEs to regulate voltages in distribution systems using an autonomous and adaptive control approach. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters with multiple DEs. Hence, the proposed control method is theoretically solid. Simulation results confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation or inefficiency. This method is autonomous based on local information and the other DEs input without the instructions from any control center, is widely adaptive to variable power system operational situations, and has a high tolerance to data shortage of systems parameter. Hence, it is suitable for broad utility application

Li, Huijuan↗

Air Conditioning Stall Phenomenon Testing, Model Development, and Simulation

Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.

air conditioning stall↗

Impacts of Varying Penetration of Distributed Resources with & without Volt/Var Control: Case Study of Varying Load Types

This paper provides a follow-up to an earlier one on impacts of distributed energy resources (DR) on distribution feeders. As DR penetration level on the feeder increases, there can be impacts to distribution system/feeder capacity, line losses, and voltage regulation. These can vary as the penetration level reaches the capacity of the distribution feeder/system or loading. The question is how high of a DR level can be accommodated without any major changes to system operation, system design and protection. Our objective for this work was to address the question of how the DR impacts vary in regards to both DR voltage regulation capability and load mix. A dynamic analysis was used to focus on the impacts of DR with and without volt/var control with different load composition on the distribution feeder. The study considered an example 10MVA distribution feeder in which two inverter-based DRs were used to provide voltage regulation. The results due to DR without voltage regulation capability are compared with DR capable of providing local (at its bus) voltage regulation. The analysis was repeated for four different feeder load compositions consisting of (1) constant power, (2) constant impedance, (3) constant current and (4) ZIP (equal combination of previous three).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Side Voltage and PQ Control with Inverter-based Photovoltaic Systems

Distributed energy resources (DER) are small generators located close to the load centers. The DERs that are integrated to the grid with the power electronic converter interfaces are capable of providing nonactive power in addition to active power. Hence, they are capable of regulating the voltages of the weak buses in the distribution systems. This paper discusses the voltage control capability of photovoltaic (PV) systems as compared to the traditional capacitor banks. The simulation results prove the effectiveness of dynamic voltage control capability of inverter-based PV. With the proper control algorithm, the active and nonactive power from the DERs like battery banks or solar photovoltaic can be controlled independently. This paper also presents the scenario of controlling the active and nonactive power from the PV array to track and supply the local load.

99 GENERAL AND MISCELLANEOUS↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Instantaneous Active and Nonactive Power Control of Distributed Energy Resources with Current Limiter

Abstract -- Distributed energy resources (DER) with a power electronics inverter interface can provide both active power and nonactive power simultaneously and independently. A decoupled control algorithm of active power and nonactive power is developed based on the instantaneous active power and nonactive power theory. A current limiter is combined to the control algorithm, and it ensures that the inverter is not overloaded. During the normal system operation, the active power has higher priority over the nonactive power so that the energy from a DER can be fully transferred to the grid. Within the inverter s capability, nonactive power is provided to the grid as required. With this control algorithm, the inverter s capabilities are taken full advantage at all times, both in terms of functionality as well as making use of its full KVA rating. Through the algorithm, the inverter s active power and nonactive power are controlled directly, simultaneously, and independently. Several experimental results fully demonstrate the validity and effectiveness of this new control algorithm. As evidenced by the fast dynamic response that results, a DER system with the control algorithm can provide full services to the grid in both steady state and during transient events.

30 DIRECT ENERGY CONVERSION↗

An Adaptive Voltage Control Algorithm with Multiple Distributed Energy

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preventing Delayed Voltage Recovery with Voltage-Regulating Distributed Energy Resources

With the large use of residential air conditioner (A/C) motors during the summer peaks, the potential of motor stalling events have increased in the recent years. The stalled motor loads have been found to be the most important cause of delayed voltage recovery following severe system disturbances, such as a subtransmission fault. The proper modeling of the stalled motors is a very important factor in identifying the effect of these motors in voltage recovery after the fault. This paper presents a methodology for modeling the stalled low inertia induction motors based on a sample utility system and a small primary distribution circuit. The prevention of the stalling of motors plays an important role in maintaining the voltage profile of the system after system disturbances. Distributed Energy Resource (DER) is used to prevent the motor stalling events so that the delayed voltage recovery of the system may be avoided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗