Engineering Papers⌕ Search

Engineering topics

Li, H.

Publications and source records attributed to Li, H..

At least 91 records · Page 5

Studies of charmed strange baryons in the Λ D final state at Belle

In this report, we discuss the discovery of Ξ c ( 3055 ) 0 , observed by its decay into the final-state Λ D 0 , and present the first observation and evidence of the decays of Ξ c ( 3055 ) + and Ξ c ( 3080 ) + into Λ D + . Furthermore, we perform a combined analysis of the Λ D + with the Σ c + + K - and Σ c * + + K - decay modes to measure the ratios of branching fractions, masses and widths with improved accuracy. We measure the ratios of branching fractions B ( Ξ c ( 3055 ) + → Λ D + ) / B ( Ξ c ( 3055 ) + → Σ c + + K - ) = 5.09 ± 1.01 ± 0.76 , B ( Ξ c ( 3080 ) + → Λ D + ) / B ( Ξ c ( 3080 ) + → Σ c + + K - ) = 1.29 ± 0.30 ± 0.15 , and B ( Ξ c ( 3080 ) + → Σ c * + + K - ) / B ( Ξ c ( 3080 ) + → Σ c + + K - ) = 1.07 ± 0.27 ± 0.04 , where the uncertainties are statistical and systematic. The analysis is performed using a 980 fb - 1 data sample collected with the Belle detector at the KEKB asymmetric-energy e + e - collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of γ γ → p p ¯ K + K - and search for exotic baryons in p K systems

The process γ γ → p p ¯ K + K - and its intermediate processes are measured for the first time using a 980 fb - 1 data sample collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. The production of p p ¯ K + K - and a Λ ( 1520 ) 0 ( Λ ¯ ( 1520 ) 0 ) signal in the p K - ( p ¯ K + ) invariant mass spectrum are clearly observed. However, no evidence for an exotic baryon near 1540 MeV / c 2 , denoted as Θ ( 1540 ) 0 ( Θ ¯ ( 1540 ) 0 ) or Θ ( 1540 ) + + ( Θ ( 1540 ) - -- ), is seen in the p K - ( p ¯ K + ) or p K + ( p ¯ K - ) invariant mass spectra. Cross sections for γ γ → p p ¯ K + K - , Λ ( 1520 ) 0 p ¯ K + + c . c . and the products σ ( γ γ → Θ ( 1540 ) 0 p ¯ K + + c . c . ) B ( Θ ( 1540 ) 0 → p K - ) and σ ( γ γ → Θ ( 1540 ) + + p ¯ K - + c . c . ) B ( Θ ( 1540 ) + + → p K + ) are measured. We also determine upper limits on the products of the χ c 0 and χ c 2 two-photon decay widths and their branching fractions to p p ¯ K + K - at the 90% credibility level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Observation of the Doubly Cabibbo-Suppressed Decay of a Charmed Baryon: Λ c + → p K + π -

We report the first observation of the decay Λ c + → p K + π - using a 980 fb - 1 data sample collected by the Belle detector at the KEKB asymmetric-energy e + e - collider. This is the first observation of a doubly Cabibbo-suppressed decay of a charmed baryon. We measure the branching ratio of this decay with respect to its Cabibbo-favored counterpart to be B ( Λ c + → p K + π - ) / B ( Λ c + → p K - π + ) = ( 2.35 ± 0.27 ± 0.21 ) × 10 - 3 , where the uncertainties are statistical and systematic, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for X Y Z states in Υ ( 1 S ) inclusive decays

The branching fractions of the Υ ( 1 S ) inclusive decays into final states with a J / ψ or a ψ ( 2 S ) are measured with higher precision to be B ( Υ ( 1 S ) → J / ψ + anything ) = ( 5.25 ± 0.13 ( stat ) ± 0.25 ( syst ) ) × 10 - 4 and B ( Υ ( 1 S ) → ψ ( 2 S ) + anything ) = ( 1.23 ± 0.17 ( stat ) ± 0.11 ( syst ) ) × 10 - 4 . The first search for Υ ( 1 S ) decays into X Y Z states that decay into a J / ψ or a ψ ( 2 S ) plus one or two charged tracks yields no significant signals for X Y Z states in any of the examined decay modes, and upper limits on their production rates in Υ ( 1 S ) inclusive decays are determined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the decay B 0 → Φ γ

We have searched for the decay B 0 → Φγ using the full Belle data set of 772 × 10 6 BB¯ pairs collected at the Υ(4S) resonance with the Belle detector at the KEKB e+e– collider. No signal is observed, and we set an upper limit on the branching fraction of B(B 0 → Φγ) < 1.0 × 10 –7 at the 90% confidence level. Here, this is the most stringent limit on this decay mode to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-E-BRB-03: Implementation of PBS Proton Therapy Treatment for Free Breathing Lung Cancer Patients

Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian.; H. Li, Na.

60 APPLIED LIFE SCIENCES↗

AlN and Al oxy-nitride gate dielectrics for reliable gate stacks on Ge and InGaAs channels

AlN and Al oxy-nitride dielectric layers are proposed instead of Al{sub 2}O{sub 3} as a component of the gate dielectric stacks on higher mobility channels in metal oxide field effect transistors to improve their positive bias stress instability reliability. It is calculated that the gap states of nitrogen vacancies in AlN lie further away in energy from the semiconductor band gap than those of oxygen vacancies in Al{sub 2}O{sub 3}, and thus AlN might be less susceptible to charge trapping and have a better reliability performance. The unfavourable defect energy level distribution in amorphous Al{sub 2}O{sub 3} is attributed to its larger coordination disorder compared to the more symmetrically bonded AlN. Al oxy-nitride is also predicted to have less tendency for charge trapping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Z b ( 10610 ) and Z b ( 10650 ) Decaying to B Mesons

We detail the analysis of the three-body e + e - → B B ¯ π ± , B B ¯ * π ± , and B * B ¯ * π ± processes, including the first observations of the Z b ± ( 10 610 ) → [ B B ¯ * + c . c . ] ± and Z b ± ( 10 650 ) → [ B * B ¯ * ] ± transitions that are found to dominate the corresponding final states. We measure Born cross sections for the three-body production of σ ( e + e - → [ B B ¯ * + c . c . ] ± π ∓ ) = [ 17.4 ± 1.6 ( stat ) ± 1.9 ( syst ) ] pb and σ ( e + e - → [ B * B ¯ * ] ± π ∓ ) = [ 8.75 ± 1.15 ( stat ) ± 1.04 ( syst ) ] pb and set a 90% C.L. upper limit of σ ( e + e - → [ B B ¯ ] ± π ∓ ) < 2.9 pb . The results are based on a 121.4 fb - 1 data sample collected with the Belle detector at a center-of-mass energy near the Υ ( 10 860 ) peak.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultralow-frequency Raman system down to 10 cm{sup −1} with longpass edge filters and its application to the interface coupling in t(2+2)LGs

Ultralow-frequency (ULF) Raman spectroscopy becomes increasingly important in the area of two-dimensional (2D) layered materials; however, such measurement usually requires expensive and nonstandard equipment. Here, the measurement of ULF Raman signal down to 10 cm{sup −1} has been realized with high throughput by combining a kind of longpass edge filters with a single monochromator, which are verified by the Raman spectrum of L-cystine using three laser excitations. Fine adjustment of the angle of incident laser beam from normal of the longpass edge filters and selection of polarization geometry are demonstrated how to probe ULF Raman signal with high signal-to-noise. Davydov splitting of the shear mode in twisted (2+2) layer graphenes (t(2+2)LG) has been observed by such system in both exfoliated and transferred samples. We provide a direct evidence of twist-angle dependent softening of the shear coupling in t(2+2)LG, while the layer-breathing coupling at twisted interfaces is found to be almost identical to that in bulk graphite. This suggests that the exfoliation and transferring techniques are enough good to make a good 2D heterostructures to demonstrate potential device application. This Raman system will be potentially applied to the research field of ULF Raman spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

60 APPLIED LIFE SCIENCES↗

Disorder-induced enhancement of indirect absorption in a GeSn photodetector grown by molecular beam epitaxy

We report an investigation on the absorption mechanism of a GeSn photodetector with 2.4% Sn composition in the active region. Responsivity is measured and absorption coefficient is calculated. Square root of absorption coefficient linearly depends on photon energy indicating an indirect transition. However, the absorption coefficient is found to be at least one order of magnitude higher than that of most other indirect materials, suggesting that the indirect optical absorption transition cannot be assisted only by phonon. Our analysis of absorption measurements by other groups on the same material system showed the values of absorption coefficient on the same order of magnitude. Our study reveals that the strong enhancement of absorption for the indirect optical transition is the result of alloy disorder from the incorporation of the much larger Sn atoms into the Ge lattice that are randomly distributed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of the Decay B s 0 → K 0 K ¯ 0

We measure the decay B$^{0}_{s}$ → K 0 K¯ 0 using data collected at the Υ(5S) resonance with the Belle detector at the KEKB e + e – collider. The data sample used corresponds to an integrated luminosity of 121.4 fb–1. We measure a branching fraction B(B$^{0}_{s}$ → K 0 K¯ 0 ) = [19.6$^{+5.8}_{–5.1}$(stat.) ± 1.0(sys.)±2.0(N B$^{0}_{s}$B¯$^{0}_{s}$ )]×10 –6 with a significance of 5.1 standard deviations. Here, this measurement constitutes the first observation of this decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sn-based Ge/Ge{sub 0.975}Sn{sub 0.025}/Ge p-i-n photodetector operated with back-side illumination

We report an investigation of a GeSn-based p-i-n photodetector grown on a Ge wafer that collects light signal from the back of the wafer. Temperature dependent absorption measurements performed over a wide temperature range (300 K down to 25 K) show that (a) absorption starts at the indirect bandgap of the active GeSn layer and continues up to the direct bandgap of the Ge wafer, and (b) the peak responsivity increases rapidly at first with decreasing temperature, then increases more slowly, followed by a decrease at the lower temperatures. The maximum responsivity happens at 125 K, which can easily be achieved with the use of liquid nitrogen. The temperature dependence of the photocurrent is analyzed by taking into consideration of the temperature dependence of the electron and hole mobility in the active layer, and the analysis result is in reasonable agreement with the data in the temperature regime where the rapid increase occurs. This investigation demonstrates the feasibility of a GeSn-based photodiode that can be operated with back-side illumination for applications in image sensing systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for the rare decay D 0 → γ γ at Belle

We search for the rare radiative decay D 0 → γγ using a data sample with an integrated luminosity of 832 fb –1 recorded by the Belle detector at the KEKB e + e – asymmetric-energy collider. Furthermore we find no statistically significant signal and set an upper limit on the branching fraction of B(D 0 → γγ) < 8.5 × 10 –7 at 90% confidence level. This is the most restrictive limit on the decay channel to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗