Engineering PapersSearch

Engineering topics

Levine, M. W.

Publications and source records attributed to Levine, M. W..

At least 19 records

Status of local oscillators for operating ultra-high resolution frequency discriminators as frequency standards

The operation of new improved frequency standards based on new ultra-high-resolution frequency discriminators requires high stability local, or 'flywheel' oscillators. We review the spectral density of phase fluctuations of existing flywheel oscillators and the related time domain frequency stability of new and proposed cryogenically cooled oscillators suitable for this application. Presently used devices include the quartz crystal oscillator, the room-temperature actively oscillating atomic hydrogen (H) maser, and the superconducting maser oscillator. Future devices include the cryogenic H-maser and other cryogenic devices using resonators of superconducting metal or solid crystalline sapphire. The relation of the phase spectral density of these devices to the characteristics of present and proposed frequency discriminators based on trapped cooled ions and cold atoms is discussed in terms of their operation as frequency standards.

Vessot, R. F. C.

Test of relativistic gravitation with a space-borne hydrogen maser

The results of a test of general relativity with use of a hydrogen-maser frequency standard in a spacecraft launched nearly vertically upward to 10,000 km are reported. The agreement of the observed relativistic frequency shift with prediction is at the 70 x 10 to the -6th level.

Vessot, R. F. C.

Gravitational redshift space-probe experiment

A Scout D rocket was launched from Wallops Island, Virginia, carrying an atomic hydrogen maser oscillator system as the payload. The frequency of signals from the oscillator was monitored on the ground at Merritt Island, Florida, by using two hydrogen masers as comparison oscillators. The first-order Doppler shift in the signals was eliminated by a go-return transponder link to the payload, and the resulting data, representing the relativistic shifts, were recovered and recorded. The objective was to measure directly the effect of gravitational potential on the frequency of an atomic hydrogen maser assuming it to be a 'proper' clock. A gravitational effect amounting to some 4.5 parts in 10 to the 10th power was measured with an oscillator having a stability better than 1 part in 10 to the 14th power. Therefore, to make the best possible use of the oscillator, all frequency shifts at the 2 to 5 X 10 to the -15 power level in delta f/f in the system must be accounted for. This includes all the phase variations that can cause such a shift to appear. The experiment, the data available and the manner in which they were processed, and the results are described.

Vessot, R. F. C.

Clock performance, reliability and cost interrelationships

Problems encountered by clock manufacturers in attempting to supply reasonably priced, reliable clocks for critical aerospace applications arise from the inherent technical difficulties of designing and fabricating equipment to provide performance at the limits of the state of the art in demanding environments. The difficulties are compounded by inconsistent and unstandardized specification practices, and by an emphasis on initial acquisition costs, rather than on life cycle costs. Conventional parts stress analyses, which do not provide a useful indication of the reliability of a clock, lead to increased parts costs for high performance aerospace clocks without comensurate benefits in improved reliability or performance. The characterization of clocks in terms of the mean time between resynchronizations, facilitates the estimation of life cycle costs and provides a means to evaluate clocks in a realistic fashion for specific systems applications.

Levine, M. W.

Performance of preproduction model cesium beam frequency standards for spacecraft applications

A cesium beam frequency standards for spaceflight application on Navigation Development Satellites was designed and fabricated and preliminary testing was completed. The cesium standard evolved from an earlier prototype model launched aboard NTS-2 and the engineering development model to be launched aboard NTS satellites during 1979. A number of design innovations, including a hybrid analog/digital integrator and the replacement of analog filters and phase detectors by clocked digital sampling techniques are discussed. Thermal and thermal-vacuum testing was concluded and test data are presented. Stability data for 10 to 10,000 seconds averaging interval, measured under laboratory conditions, are shown.

Levine, M. W.

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.

Tunable cavity resonator with ramp shaped supports

A cavity for a hydrogen maser is described consisting of three parts which provide highly stable mechanical and thermal expansion characteristics for the cavity and ease of tuning. The three parts which are made of a glass ceramic material having a very small thermal expansion coefficient (1) a top plate, (2) a cylinder with three interrupted helical ramps at its bottom, and (3) a base which includes a bottom plate and three ramp lugs on which the helical ramps of the cylinder rest when the cylinder is placed on the base with the bottom plate in the cylinder. Cavity tuning is achieved by rotating the cylinder and thereby raising or lowering it on the base, which results in changing the cylinder volume by changing the distance between the bottom and top plates.

Vessot, R. F. C.

A method of eliminating hydrogen maser wall shift

Maser output frequency shift was prevented by storage bulb kept at temperature at which wall shift is zero and effects of bulb size, shape, and surface texture are eliminated. Servo system is shown, along with bidirectional counter.

Levine, M. W.

Mechanically and thermally stable maser cavity resonator

New type cavity resonator is designed for hydrogen maser. Resonator consists of three pieces of glass-ceramic material having extremely low thermal coefficient of expansion and provides very stable mechanical tuning.

Vessot, R. F. C.

Measurement of the gravitational redshift using a clock in an orbiting satellite

A hydrogen maser clock is proposed for enclosure in an orbiting satellite to measure the gravitational effect on time scales with high accuracy. This experiment is used to test the principle of equivalence for clocks in space. Extremely narrow linewidth of Fe-57 radiation and absorption due to Mossbauer effect over 75 ft vertical distance was used to confirm the prediction of the equivalence principle to 1 part in 100. The fractional frequency shift of a satellite-borne oscillator observed from earth is also given.

Vessot, R. F. C.

System automatically tunes hydrogen masers

Automatic tuning system permits frequency synchronization between two hydrogen masers. System matches spaceborne clock performance with that of ground-based clock to test red shift theory. This system, used in conjunction with radio astronomy for long-baseline interferometer experiments, serves as a tool for investigation of distant universe phenomena.

Levine, M. W.