Engineering PapersSearch

Engineering topics

Levine, A. M.

Publications and source records attributed to Levine, A. M..

At least 19 records

RXTE and BeppoSAX Observations of the Transient X-ray Pulsar XTE J 18591+083

We present observations of the 9.8 s X-ray pulsar XTE J159+083 made with the All-Sky Monitor (ASM) and Proportional Counter Array (PCA) on board the Rossi X-ray Timing Explorer (RXTE), and the Wide Field Cameras (WFC) on board BeppoSAX. The ASM data cover a 12 year time interval and show that an extended outburst occurred between approximately MJD50, 250, and 50, 460 (1996 June 16 to 1997 January 12). The ASM data excluding this outburst interval suggest a possible 61 day modulation. Eighteen sets of PCA observations were obtained over an approx. one month interval in 1999. The flux variability measured with the PCA appears consistent with the possible period found with the ASM. The PCA measurements of the pulse period showed it to decrease non-monotonically and then to increase significantly. Doppler shifts due to orbital motion rather than accretion torques appear to be better able to explain the pulse period changes. Observations with the WFC during the extended outburst give an error box which is consistent with a previously determined PCA error box but is significantly smaller. The transient nature of XTE J1859+083 and the length of its pulse period are consistent with it being a Be/neutral star binary. The possible 61 day orbital period would be of the expected length for a Be star system with a 9.8 s pulse period.

Corbet, R. H. D.

The X-ray Timing Explorer

The capabilities of the X-ray Timing Explorer (XTE) are described with particular attention paid to current scientific problems it will address from galactic neutron star systems to active galactic nuclei. It features a low-background continuous 2-200 keV response with large apertures (a 0.63 sq m proportional counter array and a 0.16 sq m dual rocking NaI/CsI scintillation array). Rapid response (in hours) to temporal phenomena, e.g. transients, is obtained by virtue of a scanning all-sky monitor and rapid maneuverability. XTE will carry out detailed energy-resolved studies of phenomena close to neutron stars (e.g. QPO's) because of its submillisecond timing, its high telemetry rates, and the high throughput of its data system.

Bradt, H. V.

Transmission grating spectroscopy and the Advanced X-ray Astrophysics Facility (AXAF)

The use of transmission gratings with grazing-incidence telescopes in celestial X-ray astrononmy is reviewed. The basic properties of transmission grating spectrometers and the use of 'phased' gratings to enhance the diffraction efficiency are outlined. The fabrication of the gratings is examined, giving special attention to the AXAF High Energy Transmission Grating. The performance of finite-period thick gratings is briefly discussed, and the performance of the transmission grating spectrometers planned for SPECTROSAT and AXAF are examined.

Schattenburg, M. L.

Performance of high spatial frequency X-ray transmission gratings

The performance of high spatial frequency 'phased' X-ray transmission gratings developed for the High Energy Transmission Grating Spectrometer on the Advanced X-ray Astrophysics FAcility (AXAF) is examined. The gratings tested here nominally consist of 1-micron-thick gold lines of 0.2 micron period covering approximately 5 sq cm of a polyimide membrane. A table-top setup at MIT employs the gratings in reflection to diffract UV (325 nm) laser light. It is used to measure grating periods and indicates that period variations within and between gratings are a few parts in 10,000. Tests performed at the Marshall Space Flight Center 304 m X-ray Facility using 1.5 keV X-rays in transmission corroborate the UV measurements and demonstrate geometrically-limited resolving powers of E/Delta E about 750. Finally, X-ray transmission tests performed in the MIT 25 m X-ray facility provide measurements of period, line thickness, space-to-period ratio, tilt of grating lines, and efficiency.

Fischbach, K. F.

The MIT spectroscopy investigations on AXAF and the study of supernova remnants

The MIT High Resolution X-Ray Spectroscopy experiment on the AXAF, which will study physical conditions in celestial sources by means of detailed measurements of emission and absorption features in their spectra, involves two complementary dispersive instruments: Bragg Crystal Spectrometer (BCS) and High Energy Transmission Grating (HETG). This paper discusses the principles of operation of BCS and HETG and the results that will be obtained by these instruments. Measurements of individual line strengths obtained by the AXAF spectrometers will allow the application of plasma diagnostic techniques to a study of the detailed physical conditions in celestial objects, particularly in the optically thin plasma of supernova remnants, which is particularly well suited to the application of plasma diagnostics.

Canizares, C. R.

Matching a curved focal plane with CCD's - Wide field imaging of glancing incidence X-ray telescopes

The design of a wide field imaging camera suitable for use with a glancing incidence X-ray telescope is complicated by the sharply concave nature of the optimum focal surface of such a telescope. Such a camera made up of a mosaic of CCDs is being designed which is intended for flight aboard the Advanced X-ray Astrophysics Facility (AXAF). The design rationale and tradeoffs are discussed, and the layout for the imaging CCD array is presented. The related issue of optimizing performance of transmission objective gratings is also discussed, and the array of CCD orientations suitable for this problem is presented.

Nousek, J. A.

HEAO 1 high-energy X-ray observations of three bright transient X-ray sources H1705-250 (Nova Ophiuchi), H1743-322, and H1833-077 (Scutum X-1)

The bright X-ray transients H1705-250 (Nova Ophiuchi) and H1743-322 in the energy range 12-180 keV were observed, and the presence of high-energy spectral components was revealed. On the basis of X-ray spectra in the 1-10 keV range, transients are classified as 'soft' (kT = 4 keV) or 'hard' (kT = 17 keV); and both H1705-250 and H1743-322 should be in the 'soft' category. Data have been reexamined for the archetypal 'soft' transient A0600-00 taken by the SAS 3 satellite, but no evidence is found there for a high-energy spectral component. Thus consideration of a wider X-ray energy range makes the 'hard'/'soft' distinction between X-ray transients much less clear.

Cooke, B. A.

The HEAO 1 A-4 catalog of high-energy X-ray sources

Results are reported from an all-sky survey carried out at high X-ray energies (13-180 keV) from August 1977 until January 1979 using data obtained with the UCSD/MIT Hard X-Ray and Low-Energy Gamma-Ray Instrument on the HEAO 1 satellite. Visual displays are presented which indicate qualitatively the location, intensities, and time variability of the detected high-energy X-ray sources. A model-dependent procedure for the quantitative analysis of the sky survey data is described. The results of this procedure are presented in tabular form and include fitted count rates in four broad energy bands for about 70 sources. All sources which were detected at a level of statistical significance of not less than about 6 sigma were clearly evident in the visual displays of sky survey data. The survey is therefore complete, except in regions of source confusion, down to an intensity level of about 1/75 of the Crab Nebula in the 13-80 keV band. Forty-four sources were detected in the 40-80 keV energy band, and 14 were detected in the 80-180 keV band. Although most of the detected sources are galactic, seven are extragalactic.

Levine, A. M.

HEAO 1 high-energy X-ray observations of Centaurus X-3

Pulsations of 4.8 sec were detected up to energies above 38 keV by the present High Energy X-ray and Low Energy Gamma-Ray HEAO 1 satellite experiment observations of Cen X-3, and an analysis of the X-ray spectrum as a function of pulse phase indicates that the spectrum hardens during an interval of about 1.2 sec which lags the pulse peak by about 0.6 sec. The results of correlated observations of pulse period and X-ray intensity include (1) the detection of a high intensity state during which the pulse period is on the average increasing, (2) the measurement of comparable high intensities during episodes of both period increase and decrease, (3) the detection of X-ray pulsations at a much reduced level during a period of low intensity, and (4) the detection of a transition between spin-down, and spin-up episodes that coincides with a rapid decrease in X-ray intensity.

Howe, S. K.

Observations of 12-200 keV X-rays from GX 339-4

X-ray spectra of GX 339-4 measured on three occasions in 1977 and 1978 are presented. These are the first reported measurements above 10 keV. The spectra can be described as the superposition of a soft component, which is dominant below about 20 keV, and a hard component at higher energy. Simultaneous measurements at lower energy show that the soft component vanished during the observation in early 1978. The behavior of these two components is similar to that of the spectrum of Cygnus X-1; this reinforces the previously noted resemblance in rapid X-ray variability.

Nolan, P. L.

On the orbital phase dependence of the turn-on times of Hercules X-1

The present investigation is concerned with the dynamics of tilted accretion disks in binary systems. It is shown that the expected motion of a ring of matter in an accretion disk is more complicated than simple precession at a uniform rate. The motion is found to be better described by a vector normal to the plane of the ring of matter whose tip periodically traces out a small ellipse centered on the tip of a uniformly precessing vector. It is also demonstrated that this 'wobble' can be utilized to explain why the turn-ons of Hercules X-1 preferentially occur around orbital phases 0.2 and 0.7. If an accretion disk in a binary system is tilted with respect to the binary orbital plane, then it must undergo forced precession with the corresponding 'wobble'. This 'wobble' may be, at least, partially responsible for the phase dependence of the distribution of X-ray turn-on times of Hercules X-1.

Levine, A. M.

HEAO 1 observations of high-energy X-rays from the Seyfert I galaxy Mkn 509

The results of observations of the Seyfert I galaxy Mkn 509 at high X-ray energies (14-140 keV) with the UCSD/MIT instrument aboard HEAO 1 are reported. The source is detected at energies above 40 keV, and the spectrum is consistent with an extrapolation of the power-law spectrum obtained at lower X-ray energies. Observations on four separate days in 1978 October indicate that the source is varying on a time scale of days.

Dil, S.

Hard X-ray spectrum of Cygnus X-1

Long-term measurements of the hard X-ray spectrum from 3 keV to 8 MeV of the black-hole candidate Cygnus X-1 in its low state are reported. Observations were made from October 26 to November 18, 1977 with the A2 (Cosmic X-ray) and A4 (Hard X-ray and Low-Energy Gamma-Ray) experiments on board HEAO 1 in the spacecraft's scanning mode. The measured spectrum below 200 keV is found to agree well with previous spectra which have been fit by a model of the Compton scattering of optical or UV photons in a very hot plasma of electron temperature 32.4 keV and optical depth 3.9 or 1.6 for spherical or disk geometry, respectively. At energies above 300 keV, however, flux excess is observed which may be accounted for by a distribution of electron temperatures from 15 to about 100 keV.

Nolan, P. L.

The hard X-ray spectrum of X Persei

Results of observations of 3U 0352 + 30, the source associated with the X Persei system, in the energy range 12-180 keV are reported. The measurements were made on 1978 August 22 with the UCSD/MIT High-Energy X-ray and Low-Energy Gamma-ray Experiment on HEAO 1. Data taken simultaneously in the energy range 2-50 keV indicate that, in addition to a 7 keV thermal bremsstrahlung component, there is a second component of higher energy. It is found that this higher energy component fits a power law of photon index 1.3 (+0.4, -0.5) and is pulsed at the 13.95 minute period of the lower energy component.

Worrall, D. M.

High energy X-ray observations of the 38-second pulsar

The results of observations of the 38-second pulsar obtained at high X-ray energies (13-180 keV) with the UCSD/MIT instrument aboard HEAO 1 are reported. The results include a measurement of the source location, measurement of the pulse profile, and determination of the average intensity and spectrum during each of three time intervals spanning a baseline of 1 year. The total intensity of the pulsar is seen to vary on a 6-month time scale. The spectrum is hard but, like other X-ray pulsars, steepens at energies above 20 keV.

Byrne, P. F.

Rapid variability of 10-140 keV X-rays from Cygnus X-1

On five occasions in 1977 and 1978, Cygnus X-1 was observed using the low-energy detectors of the UCSD/MIT Hard X-ray and Low-Energy Gamma Ray experiment on the HEAO 1 satellite. Rapid (times between 0.08 and 1000 sec) variability was found in the 10-140 keV band. The power spectrum was white for frequencies between 0.001 and 0.05 Hz and was proportional to the inverse of the frequency for frequencies between 0.05 and 3 Hz, indicating correlations on all time scales less than approximately 20 s. The shape of the energy spectrum was correlated with intensity; it was harder at higher intensity. If the emission is produced by Comptonization of a soft photon flux in a hot cloud, the heating of the cloud cannot be constant; it must vary on time scales up to approximately 20 s. A variable accretion rate could cause the observed effects.

Nolan, P. L.

HEAO 1 observations of the Perseus cluster above 10 keV

Results are presented of HEAO 1 observations of the Perseus cluster from 10 to 150 keV in 1977 August and 1978 February and August. The spectrum exhibits a previously unknown hard (greater than 25 keV) component in addition to the previously known thermal bremsstrahlung emission. The data presented show no significant evidence of variability from 10.5 keV to 93.5 keV, and a comparison of our results with earlier results indicates no strong evidence for variability above 25 keV over a time scale of 4 yr. If the hard-component excess is due to NGC 1275, the data imply a 2-6 keV X-ray luminosity of 1 x 10 to the 44th ergs/s for the galaxy, or about 15% of the total cluster emission from 2 to 6 keV and a 25-40 keV luminosity of 8 x 10 to the 43rd ergs/s.

Primini, F. A.