Engineering Papers⌕ Search

Engineering topics

Leonard, D. S.

Publications and source records attributed to Leonard, D. S..

At least 19 records

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on Covariant Dark-Matter–Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the scalar WIMP-pion coupling with the first LUX-ZEPLIN data

Weakly interacting massive particles (WIMPs) may interact with a virtual pion that is exchanged between nucleons. This interaction channel is important to consider in models where the spin-independent isoscalar channel is suppressed. Using data from the first science run of the LUX-ZEPLIN dark matter experiment, containing 60 live days of data in a 5.5 tonne fiducial mass of liquid xenon, we report the results on a search for WIMP-pion interactions. We observe no significant excess and set an upper limit of 1.5 × 10$^{−46}$ cm$^{2}$ at a 90% confidence level for a WIMP mass of 33 GeV/c$^{2}$ for this interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New constraints on ultraheavy dark matter from the LZ experiment

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV / c 2 to a few TeV / c 2 . Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a reanalysis of the first science run of the LZ experiment, with an exposure of 0.9 tonne × yr , to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10 17 GeV / c 2 . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First constraints on WIMP-nucleon effective field theory couplings in an extended energy region from LUX-ZEPLIN

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead, South Dakota, USA, we report the initial limits on a model-independent nonrelativistic effective field theory describing the complete set of possible interactions of a weakly interacting massive particle (WIMP) with a nucleon. These results utilize the same 5.5 t fiducial mass and 60 live days of exposure collected for the LZ spin-independent and spin-dependent analyses while extending the upper limit of the energy region of interest by a factor of 7.5 to 270 keV. No significant excess in this high energy region is observed. Using a profile-likelihood ratio analysis, we report 90% confidence level exclusion limits on the coupling of each individual nonrelativistic WIMP-nucleon operator for both elastic and inelastic interactions in the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Cosmogenic production of 37 Ar in the context of the LUX-ZEPLIN experiment

We estimate the amount of 37 Ar produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth’s surface. We then calculate the resulting 37 Ar concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of 37 Ar in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average 37 Ar activity after 10 tons are purified and transported underground is 0.058 − 0.090 𝜇⁢Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic 37 Ar will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of 37 Ar should be considered when planning for future liquid-xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Projected sensitivity of the LUX-ZEPLIN experiment to the two-neutrino and neutrinoless double $\beta$ decays of $^{134}$Xe

The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of 134 Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of 134 Xe, for which xenon detectors enriched in 136 Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7 x 10 24 years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7 x 10 23 years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3 x 10 24 years at 90% CL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils

LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝⁢𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗