SU-F-T-519: Is Geometry Based Setup Sufficient for All of the Head and Neck Treatment Cases?: A Feasibility Study Towards the Dose Based Setup

Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported along with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.

60 APPLIED LIFE SCIENCES↗

SU-F-T-580: New Tumor Modeling Using 3D Gel Dosimeter for Brain Stereoctactic Radiotherpy (SRT)

Purpose: The purpose of this study is to develop new tumor model using 3D printing with 3D dosimeter for brain stereoctactic radiotherpy (SRT). Methods: BANG{sup 3} polymer gel was prepared and the gel-filled glass vials were irradiated with a 6 MV photon beam to acquire the calibration curve that present the change of R2 (1/T{sub 2}) value with dose. Graded doses from 0 to 12 Gy with an interval of 2 Gy were delivered. A kit for calibration of gel dosimeter and an 2 tumor model phantoms with a spherical shape were produced using a 3D printer with a polylactic acid after its 3D images were created using Autodesk software. 3D printed tumor phantoms and EBT3 films were irradiated to compare with treatment plan. After irradiation, vials for calibration and tumor model phantoms were scanned at 9.4T MRI. The spin-spin relaxation times (T{sub 2}) according to the each dose were calculated to evaluate the dose response. Acquired images were analyzed using an ImageJ. Scanned MRI images of tumor models were transferred treatment planning system and these were registered to the CT images. In all treatment plans, two arc plans (CW and CCW) were designed to deliver 50 Gy for 10 fractions. For first PTV, treatment plan was accurately designed that 95% of dose to cover 100% of PTV. But 2nd PTV was not intentionally cover 100% of PTV to evaluate the intensity of delivered tumor phantom with polymer gel. We compared the 3D dose distributions obtained from measurements with the 3D printed phantom and calculated with the TPS. Results: 3D printed phantom with a polymer gel was successfully produced. The dose distributions showed qualitatively good agreement among gel, film, and RTP data. Conclusion: A hybrid phantom represents a useful to validate the 3D dose distributions for patient-specific QA.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-01: A Novel 3D Printed Patient-Specific Phantom for Spine SBRT Quality Assurance: Comparison of 3D Printing Techniques

Purpose: The novel 3 dimensional (3D)-printed spine quality assurance (QA) phantoms generated by two different 3D-printing technologies, digital light processing (DLP) and Polyjet, were developed and evaluated for spine stereotactic body radiation treatment (SBRT). Methods: The developed 3D-printed spine QA phantom consisted of an acrylic body and a 3D-printed spine phantom. DLP and Polyjet 3D printers using the high-density acrylic polymer were employed to produce spine-shaped phantoms based on CT images. To verify dosimetric effects, the novel phantom was made it enable to insert films between each slabs of acrylic body phantom. Also, for measuring internal dose of spine, 3D-printed spine phantom was designed as divided laterally exactly in half. Image fusion was performed to evaluate the reproducibility of our phantom, and the Hounsfield unit (HU) was measured based on each CT image. Intensity-modulated radiotherapy plans to deliver a fraction of a 16 Gy dose to a planning target volume (PTV) based on the two 3D-printing techniques were compared for target coverage and normal organ-sparing. Results: Image fusion demonstrated good reproducibility of the fabricated spine QA phantom. The HU values of the DLP- and Polyjet-printed spine vertebrae differed by 54.3 on average. The PTV Dmax dose for the DLP-generated phantom was about 1.488 Gy higher than for the Polyjet-generated phantom. The organs at risk received a lower dose when the DLP technique was used than when the Polyjet technique was used. Conclusion: This study confirmed that a novel 3D-printed phantom mimicking a high-density organ can be created based on CT images, and that a developed 3D-printed spine phantom could be utilized in patient-specific QA for SBRT. Despite using the same main material, DLP and Polyjet yielded different HU values. Therefore, the printing technique and materials must be carefully chosen in order to accurately produce a patient-specific QA phantom.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-02: Dose Reduction in Contrast-Enhanced Digital Mammography Using a Photon-Counting Detector

Purpose: Photon-counting detectors (PCDs) allow multi-energy X-ray imaging without additional exposures and spectral overlap. This capability results in the improvement of accuracy of material decomposition for dual-energy X-ray imaging and the reduction of radiation dose. In this study, the PCD-based contrast-enhanced dual-energy mammography (CEDM) was compared with the conventional CDEM in terms of radiation dose, image quality and accuracy of material decomposition. Methods: A dual-energy model was designed by using Beer-Lambert’s law and rational inverse fitting function for decomposing materials from a polychromatic X-ray source. A cadmium zinc telluride (CZT)-based PCD, which has five energy thresholds, and iodine solutions included in a 3D half-cylindrical phantom, which composed of 50% glandular and 50% adipose tissues, were simulated by using a Monte Carlo simulation tool. The low- and high-energy images were obtained in accordance with the clinical exposure conditions for the conventional CDEM. Energy bins of 20–33 and 34–50 keV were defined from X-ray energy spectra simulated at 50 kVp with different dose levels for implementing the PCD-based CDEM. The dual-energy mammographic techniques were compared by means of absorbed dose, noise property and normalized root-mean-square error (NRMSE). Results: Comparing to the conventional CEDM, the iodine solutions were clearly decomposed for the PCD-based CEDM. Although the radiation dose for the PCD-based CDEM was lower than that for the conventional CEDM, the PCD-based CDEM improved the noise property and accuracy of decomposition images. Conclusion: This study demonstrates that the PCD-based CDEM allows the quantitative material decomposition, and reduces radiation dose in comparison with the conventional CDEM. Therefore, the PCD-based CDEM is able to provide useful information for detecting breast tumor and enhancing diagnostic accuracy in mammography.

60 APPLIED LIFE SCIENCES↗

TU-D-201-03: Results of a Survey On the Implementation of the TG-51 Protocol and Associated Addendum On Reference Dosimetry of External Beams

Purpose: The working group on the review and extension of the TG-51 protocol (WGTG51) collected data from American Association of Physicists in Medicine (AAPM) members with respect to their current TG-51 and associated addendum usage in the interest of considering future protocol addenda and guidance on reference dosimetry best practices. This study reports an overview of this survey on dosimetry of external beams. Methods: Fourteen survey questions were developed by WGTG51 and released in November 2015. The questions collected information on reference dosimetry, beam quality specification, and ancillary calibration equipment. Results: Of the 190 submissions completed worldwide (U.S. 70%), 83% were AAPM members. Of the respondents, 33.5% implemented the TG-51 addendum, with the maximum calibration difference for any photon beam, with respect to the original TG-51 protocol, being <1% for 97.4% of responses. One major finding is that 81.8% of respondents used the same cylindrical ionization chamber for photon and electron dosimetry, implying that many clinics are foregoing the use of parallel-plate chambers. Other evidence suggests equivalent dosimetric results can be obtained with both cylindrical and parallel-plate chambers in electron beams. This, combined with users comfort with cylindrical chambers for electrons will likely impact recommendations put forward in an upcoming electron beam addendum to the TG-51 protocol. Data collected on ancillary equipment showed 58.2% (45.0%) of the thermometers (barometers) in use for beam calibration had NIST traceable calibration certificates, but 48.4% (42.7%) were never recalibrated. Conclusion: This survey provides a snapshot of TG-51 external beam reference dosimetry practice in radiotherapy centers. Findings demonstrate the rapid take-up of the TG-51 photon beam addendum and raise issues for the WGTG51 to focus on going forward, including guidelines on ancillary equipment and the choice of chamber for electron beam dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-H-CAMPUS-IeP1-03: Comparison of Monte Carlo Simulation and Conversion Factor Based Method On Estimation of Effective Dose in Pediatric Patients Undergoing Interventional Cardiac Procedures

Purpose: Interventional cardiac procedures utilize frequent fluoroscopy and cineangiography, which impose considerable radiation risk to patients, especially pediatric patients. Accurate calculation of effective dose is important in order to estimate cancer risk over the rest of their lifetime. This study evaluates the difference in effective dose calculated by Monte Carlo simulation with those estimated by locally-derived conversion factors (CF-local) and by commonly quoted conversion factors from Karambatsakidou et al (CF-K). Methods: Effective dose (E),of 12 pediatric patients, age between 2.5–19 years old, who had undergone interventional cardiac procedures, were calculated using PCXMC-2.0 software. Tube spectrum, irradiation geometry, exposure parameters and dose-area product (DAP) of each projection were included in the software calculation. Effective doses for each patient were also estimated by two Methods: 1) CF-local: conversion factor derived locally by generalizing results of 12 patients, multiplied by DAP of each patient gives E-local. 2) CF-K: selected factor from above-mentioned literature, multiplied by DAP of each patient gives E-K. Results: Mean of E, E-local and E-K were 16.01 mSv, 16.80 mSv and 22.25 mSv respectively. A deviation of −29.35% to +34.85% between E and E-local, while a greater deviation of −28.96% to +60.86% between E and EK were observed. E-K overestimated the effective dose for patients at age 7.5–19. Conclusion: Effective dose obtained by conversion factors is simple and quick to estimate radiation risk of pediatric patients. This study showed that estimation by CF-local may bear an error of 35% when compared with Monte Carlo calculation. If using conversion factors derived by other studies may result in an even greater error, of up to 60%, due to factors that are not catered for in the estimation, including patient size, projection angles, exposure parameters, tube filtration, etc. Users must be aware of these potential inaccuracies when simple conversion method is employed.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks

Purpose: Radiotherapy treatment is specified by radiation dose prescriptions, but biological DNA damage actually controls treatment effectiveness. It is impractical to directly measure dose in the clinic, so we measure quantities, such as collected charge, and calculate the relationship to dose. At small fields, such as those in stereotactic radiosurgery (SRS), charged-particle equilibrium (CPE) breaks down and the accuracy of the measurement for delivered dose decreases. By measuring DNA double-strand breaks (DSB) directly, we believe treatment accuracy could improve by providing a more meaningful measurement. Methods: A DNA dosimeter, consisting of magnetic streptavidin beads attached to 4 kilobase pair DNA strands labeled with biotin and fluorescein amidite (FAM) on opposing ends, was suspended in phosphate-buffered saline (PBS). Twenty µL samples were placed in plastic micro-capillary tubes inside a water tank setup and irradiated with 10 cm, 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm radiation field sizes, where the three smallest sizes were cones. After irradiation, the dosimeters were mechanically separated into beads (intact DNA) and supernatant (broken DNA/FAM) using a magnet. The fluorescence was read and the probability of DSB was calculated. This was used to calculate the output factor for an SRS beam and compared to that measured using a diode detector. Results: The output factors relative to a 10 cm field were 0.89±0.07, 0.76±0.08, 0.59±0.04, and 0.78±0.12 for the field sizes of 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm, respectively. Some of the diode measurements do not fall within these uncertainties. Conclusion: This was the first attempt to measure output factors in a water tank with the DNA dosimeter. Although differences compared to the diode were observed, the uncertainty analysis ignored systematic errors. For future work, we will repeat this experiment to quantify and correct systematic errors, such as those caused by positional alignment and sample contamination. This work was funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

WE-FG-206-06: Dual-Input Tracer Kinetic Modeling and Its Analog Implementation for Dynamic Contrast-Enhanced (DCE-) MRI of Malignant Mesothelioma (MPM)

Purpose: To use dual-input tracer kinetic modeling of the lung for mapping spatial heterogeneity of various kinetic parameters in malignant MPM Methods: Six MPM patients received DCE-MRI as part of their radiation therapy simulation scan. 5 patients had the epitheloid subtype of MPM, while one was biphasic. A 3D fast-field echo sequence with TR/TE/Flip angle of 3.62ms/1.69ms/15° was used for DCE-MRI acquisition. The scan was collected for 5 minutes with a temporal resolution of 5-9 seconds depending on the spatial extent of the tumor. A principal component analysis-based groupwise deformable registration was used to co-register all the DCE-MRI series for motion compensation. All the images were analyzed using five different dual-input tracer kinetic models implemented in analog continuous-time formalism: the Tofts-Kety (TK), extended TK (ETK), two compartment exchange (2CX), adiabatic approximation to the tissue homogeneity (AATH), and distributed parameter (DP) models. The following parameters were computed for each model: total blood flow (BF), pulmonary flow fraction (γ), pulmonary blood flow (BF-pa), systemic blood flow (BF-a), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), fractional interstitial volume (vi), extraction fraction (E), volume transfer constant (Ktrans) and efflux rate constant (kep). Results: Although the majority of patients had epitheloid histologies, kinetic parameter values varied across different models. One patient showed a higher total BF value in all models among the epitheloid histologies, although the γ value was varying among these different models. In one tumor with a large area of necrosis, the TK and ETK models showed higher E, Ktrans, and kep values and lower interstitial volume as compared to AATH and DP and 2CX models. Kinetic parameters such as BF-pa, BF-a, PS, Ktrans values were higher in surviving group compared to non-surviving group across most models. Conclusion: Dual-input tracer kinetic modeling is feasible in determining micro-vascular characteristics of MPM. This project was supported from Cycle for Survival and MSK Imaging and radiation science (IMRAS) grants.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-06: Optimizing Four-Dimensional Digital Tomosynthesis Acquisition Based On Respiratory Guidance

Purpose: Patient breathing-related sorting method of projections in 4D digital tomosythesis (DTS) can be suffered from severe artifacts due to non-uniform angle distribution of projections and noncoplanar reconstructed images for each phase. In this study, we propose a method for optimally acquiring projection images in 4D DTS. Methods: In this method every pair of projections at x-ray tube’s gantry angles symmetrical with respect to the center of the range of gantry rotation is obtained at the same respiration amplitude. This process is challenging but becomes feasible with visual-biofeedback using a patient specific respiration guide wave which is in sinusoidal shape (i.e., smooth and symmetrical enough). Depending on scan parameters such as the number of acquisition points per cycle, total scan angle and projections per acquisition amplitude, acquisition sequence is pre-determined. A simulation study for feasibility test was performed. To mimic actual situation closely, a group of volunteers were recruited and breathing data were acquired both with/without biofeedback. Then, x-ray projections for a humanoid phantom were virtually performed following (1) the breathing data from volunteers without guide, (2) the breathing data with guide and (3) the planned breathing data (i.e., ideal situation). Images from all of 3 scenarios were compared. Results: Scenario #2 showed significant artifact reduction compared to #1 while did minimal increase from the ideal situation (i.e., scenario #3). We verified the performance of the method with regard to the degree of inaccuracy during respiratory guiding. Also, the scan angle dependence-related differences in the DTS images could reduce between using the proposed method and the established patient breathing-related sorting method. Conclusion: Through the proposed 4D DTS method, it is possible to improve the accuracy of image guidance between intra/inter fractions with relatively low imaging dose. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

SU-C-304-05: Use of Local Noise Power Spectrum and Wavelets in Comprehensive EPID Quality Assurance

Purpose: As EPIDs are increasingly used for IMRT QA and real-time treatment verification, comprehensive quality assurance (QA) of EPIDs becomes critical. Current QA with phantoms such as the Las Vegas and PIPSpro™ can fail in the early detection of EPID artifacts. Beyond image quality assessment, we propose a quantitative methodology using local noise power spectrum (NPS) to characterize image noise and wavelet transform to identify bad pixels and inter-subpanel flat-fielding artifacts. Methods: A total of 93 image sets including bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Quantitative metrics such as modulation transform function (MTF), NPS and detective quantum efficiency (DQE) were computed for each image set. Local 2D NPS was calculated for each subpanel. A 1D NPS was obtained by radial averaging the 2D NPS and fitted to a power-law function. R-square and slope of the linear regression analysis were used for panel performance assessment. Haar wavelet transformation was employed to identify pixel defects and non-uniform gain correction across subpanels. Results: Overall image quality was assessed with DQE based on empirically derived area under curve (AUC) thresholds. Using linear regression analysis of 1D NPS, panels with acceptable flat fielding were indicated by r-square between 0.8 and 1, and slopes of −0.4 to −0.7. However, for panels requiring flat fielding recalibration, r-square values less than 0.8 and slopes from +0.2 to −0.4 were observed. The wavelet transform successfully identified pixel defects and inter-subpanel flat fielding artifacts. Standard QA with the Las Vegas and PIPSpro phantoms failed to detect these artifacts. Conclusion: The proposed QA methodology is promising for the early detection of imaging and dosimetric artifacts of EPIDs. Local NPS can accurately characterize the noise level within each subpanel, while the wavelet transforms can detect bad pixels and inter-subpanel flat fielding artifacts.

60 APPLIED LIFE SCIENCES↗

SU-E-P-05: Electronic Brachytherapy: A Physics Perspective On Field Implementation

Purpose: We want to summarize our experience implementing a successful program of electronic brachytherapy at several dermatology clinics with the help of a cloud based software to help us define the key program parameters and capture physics QA aspects. Optimally developed software helps the physicist in peer review and qualify the physical parameters. Methods: Using the XOFT™ Axxent™ electronic brachytherapy system in conjunction with a cloud-based software, a process was setup to capture and record treatments. It was implemented initially at about 10 sites in California. For dosimetric purposes, the software facilitated storage of the physics parameters of surface applicators used in treatment and other source calibration parameters. In addition, the patient prescription, pathology and other setup considerations were input by radiation oncologist and the therapist. This facilitated physics planning of the treatment parameters and also independent check of the dwell time. From 2013–2014, nearly1500 such calculation were completed by a group of physicists. A total of 800 patients with multiple lesions have been treated successfully during this period. The treatment log files have been uploaded and documented in the software which facilitated physics peer review of treatments per the standards in place by AAPM and ACR. Results: The program model was implemented successfully at multiple sites. The cloud based software allowed for proper peer review and compliance of the program at 10 clinical sites. Dosimtery was done on 800 patients and executed in a timely fashion to suit the clinical needs. Accumulated physics data in the software from the clinics allows for robust analysis and future development. Conclusion: Electronic brachytherapy implementation experience from a quality assurance perspective was greatly enhanced by using a cloud based software. The comprehensive database will pave the way for future developments to yield superior physics outcomes.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-172: Bio-Physical Effects of Patients Set-Up Errors According to Whole Breast Irradiation Techniques

Purpose: The dose-related effects of patient setup errors on biophysical indices were evaluated for conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques. Methods: The treatment plans for 10 patients receiving whole left breast irradiation were retrospectively selected. Radiobiological and physical effects caused by dose variations were evaluated by shifting the isocenters and gantry angles of the treatment plans. Dose-volume histograms of the planning target volume (PTV), heart, and lungs were generated, and conformity index (CI), homogeneity index (HI), tumor control probability (TCP), and normal tissue complication probability (NTCP) were determined. Results: For “isocenter shift plan” with posterior direction, the D95 of the PTV decreased by approximately 15% and the TCP of the PTV decreased by approximately 50% for the FIF technique and by 40% for the CW; however, the NTCPs of the lungs and heart increased by about 13% and 1%, respectively, for both techniques. Increasing the gantry angle decreased the TCPs of the PTV by 24.4% (CW) and by 34% (FIF). The NTCPs for the two techniques differed by only 3%. In case of CW, the CIs and HIs were much higher than that of the FIF in all cases. It had a significant difference between two techniques (p<0.01). According to our results, however, the FIF had more sensitive response by set up errors rather than CW in bio-physical aspects. Conclusions: The radiobiological-based analysis can detect significant dosimetric errors then, can provide a practical patient quality assurance method to guide the radiobiological and physical effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after the same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye award; Disclosure/Conflict of interest: Raymond H. Mak: Stock ownership: Celgene, Inc. Consulting: Boehringer-Ingelheim, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-08: A Beam Source Model for Monte Carlo Simulations of a Double-Scattering Proton Beam Delivery System Using Beam Current Modulation

Purpose: To reconstruct phase-space information upstream of patient specific collimators for Monte Carlo simulations using only radiotherapy planning system data. Methods: The proton energies are calculated based on residual ranges, e.g., sum of prescribed ranges in a patient and SSD. The Kapchinskij and Vladimirskij (KV) distribution was applied to sample proton’s x-y positions and momentum direction and the beam shape was assumed to be a circle. Free parameters, e.g., the initial energy spread and the emittance of KV distribution were estimated from the benchmarking with commissioning data in a commercial treatment planning system for an operational proton therapy center. The number of histories, which defines the height of individual pristine Bragg peaks (BP) of Spread-out Bragg peak (SOBP), are weighted based on beam current modulation and a correction factor is applied to take into account the fluence reduction as the residual range decreases due to the rotation of the range modulator wheel. The timedependent behaviors, e.g., the changes of the residual range and histories per a pristine BP, are realized by utilizing TOPAS (Tool for Particle Simulation). Results: Benchmarking simulations for selected SOBPs ranging 7.5 cm to 15.5 cm matched within 2 mm in range and up to 5 mm in SOBP width against measurement data in water phantom. We found this model tends to underestimate entrance dose by about 5 % in comparison to measurement. This was attributed to the situation that the energy distribution used in the model was limited in its granularity at the limit of single energy spectrum for the narrow angle modulator steps used in the proximal pull back region of the SOBPs. Conclusion: Within these limitations the source modeling method proved itself an acceptable alternative of a full treatment head simulation when the machine geometry and materials information are not available.

60 APPLIED LIFE SCIENCES↗

SU-E-T-159: Characteristics of Fiber-Optic Radiation Sensor for Proton Therapeutic Beam

Purpose: A fiber-optic radiation sensor using Cerenkov radiation has been widely studied for use as a dosimeter for proton therapeutic beam. Although the fiber-optic radiation sensor has already been investigated for proton therapeutic, it has been examined relatively little work for clinical therapeutic proton beams. In this study, we evaluated characteristics of a fiber-optic radiation sensor for clinical therapeutic proton beams. We experimentally evaluated dose-rate dependence, dose response and energy dependence for the proton beam. Methods: A fiber-optic radiation sensor was placed in a water phantom. Beams with energies of low, middle and high were used in the passively-scattered proton therapeutic beam at the National Cancer Center in Korea. The sensor consists of two plastic optical fibers (POF). A reference POF and 2 cm longer POF were used to utilize the subtraction method for having sensitive volume. Each POF is optically coupled to the Multi-Anode Photo Multiplier Tube (MAPMT) and the MAPMT signals are processed using National Instruments Data Acquisition System (NI-DAQ). We were investigated dosimetric properties including dose-rate dependence, dose response and energy dependence. Results: We have successfully evaluated characteristics of a fiber optic radiation sensor using Cerenkov radiation. The fiber-optic radiation sensor showed the dose response linearity and low energy dependence. In addition, as the dose-rate was increased, Cerenkov radiation increased linearly. Conclusion: We evaluated the basic characteristics of the fiber optic radiation sensor, the dosimetry tool, to raise the quality of proton therapy. Based on the research, we developed a real time dosimetry system of the optic fiber to confirm the real time beam position and energy for therapeutic proton pencil beam.

60 APPLIED LIFE SCIENCES↗

SU-E-T-257: Development of a New Endorectal Balloon with An Unfoldable Radiochromic Film for In-Vivo Rectal Dosimetry During Prostate Cancer Radiotherapy

Purpose: We developed an endorectal balloon for in-vivo rectal dosimetry in two-dimensions, and evaluated its dosimetric properties for the radiation treatment of prostate cancer. Methods: The endorectal balloon for in-vivo rectal dosimetry is equipped with a radiochromic film so that two-dimensional dose distribution can be measured in the rectal wall. The film is unrolled as the balloon is inflated, and it is rolled as the balloon is deflated. The outer diameter of the balloon is about 14 mm before inflating it, but its outer diameter can be increased up to about 50 mm after inflating it with 80 ml distilled water. The size of the film is 80(L) x 64(W) mm2, so large as to measure a dose distribution of an anterior half of the rectal wall. After it was inserted into a fabricated rectal phantom, the phantom was scanned by a CT scanner and 5 Gy was delivered to a target inside the phantom with a 15 MV photon beam in AP direction. Finally, the dose distribution measured in the endorectal balloon was compared with that of the treatment plan. Results: The two dose distributions were compared each other in the parallel and the perpendicular directions along an axis of the balloon. The two dose profiles analyzed from the radiochromic film agreed well with the plan within 3% for 15 MV photon beam. Conclusion: An endorectal balloon for two-dimensional in-vivo rectal dosimetry was developed and its dosimetric effectiveness was evaluated for the radiation treatment of prostate cancer. The measured dose distributions showed good agreement with the plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗