Engineering Papers⌕ Search

Engineering topics

Lee, Michael H.

Publications and source records attributed to Lee, Michael H..

Bacterial amyloid curli acts as a carrier for DNA to elicit an autoimmune response via TLR2 and TLR9

Bacterial biofilms are associated with numerous human infections. The predominant protein expressed in enteric biofilms is the amyloid curli, which forms highly immunogenic complexes with DNA. Infection with curli-expressing bacteria or systemic exposure to purified curli-DNA complexes triggers autoimmunity via the generation of type I interferons (IFNs) and anti-double-stranded DNA antibodies. Here, we show that DNA complexed with amyloid curli powerfully stimulates Toll-like receptor 9 (TLR9) through a two-step mechanism. First, the cross beta-sheet structure of curli is bound by cell-surface Toll-like receptor 2 (TLR2), enabling internalization of the complex into endosomes. After internalization, the curli-DNA immune complex binds strongly to endosomal TLR9, inducing production of type I IFNs. Analysis of wild-type and TLR2-deficient macrophages showed that TLR2 is the major receptor that drives the internalization of curli-DNA complexes. Suppression of TLR2 internalization via endocytosis inhibitors led to a significant decrease in Ifnβ expression. Confocal microscopy analysis confirmed that the TLR2-bound curli was required for shuttling of DNA to endosomal TLR9. Structural analysis using small-angle X-ray scattering revealed that incorporation of DNA into curli fibrils resulted in the formation of ordered curli-DNA immune complexes. Curli organizes parallel, double-stranded DNA rods at an inter-DNA spacing that matches up well with the steric size of TLR9. We also found that production of anti-double-stranded DNA autoantibodies in response to curli-DNA was attenuated in TLR2- and TLR9-deficient mice and in mice deficient in both TLR2 and TLR9 compared to wild-type mice, suggesting that both innate immune receptors are critical for shaping the autoimmune adaptive immune response. We also detected significantly lower levels of interferon-stimulated gene expression in response to purified curli-DNA in TLR2 and TLR9 deficient mice compared to wild-type mice, confirming that TLR2 and TLR9 are required for the induction of type I IFNs. Finally, we showed that curli-DNA complexes, but not cellulose, were responsible elicitation of the immune responses to bacterial biofilms. This study defines the series of events that lead to the severe pro-autoimmune effects of amyloid-expressing bacteria and suggest a mechanism by which amyloid curli acts as a carrier to break immune tolerance to DNA, leading to the activation of TLR9, production of type I IFNs, and subsequent production of autoantibodies.

59 BASIC BIOLOGICAL SCIENCES↗

Coil system for plasmoid thruster

A coil system for a plasmoid thruster includes a bias coil, a drive coil and field coils. The bias and drive coils are interleaved with one another as they are helically wound about a conical region. A first field coil defines a first passage at one end of the conical region, and is connected in series with the bias coil. A second field coil defines a second passage at an opposing end of the conical region, and is connected in series with the bias coil.

Eskridge, Richard H.↗

Probing a Spray Using Frequency-Analyzed Light Scattering

Frequency-analyzed laser-light scattering (FALLS) is a relatively simple technique that can be used to measure principal characteristics of a sheet of sprayed liquid as it breaks up into ligaments and then the ligaments break up into droplets. In particular, through frequency analysis of laser light scattered from a spray, it is possible to determine whether the laser-illuminated portion of the spray is in the intact-sheet region, the ligament region, or the droplet region. By logical extension, it is possible to determine the intact length from the location of the laser beam at the transition between the intact-sheet and ligament regions and to determine a breakup frequency from the results of the frequency analysis. Hence, FALLS could likely be useful both as a means of performing research on sprays in general and as a means of diagnostic sensing in diverse applications in which liquid fuels are sprayed. Sprays are also used for drying and to deposit paints and other coating materials.

Eskridge, Richard↗

Magnetic and Langmuir Probe Measurements on the Plasmoid Thruster Experiment (PTX)

The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and ejecting them at high velocity. A plasmoid is a plasma with an imbedded closed magnetic field structure. The shape and magnetic field structure of the translating plasmoids have been measured with of an array of magnetic field probes. Six sets of two B-dot probes were constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes are wound on a square G10 form, and have an average (calibrated) NA of 9.37 x l0(exp -5) square meters, where N is the number of turns and A is the cross-sectional area. The probes were calibrated with a Helmholtz coil, driven by a high-voltage pulser to measure NA, and by a signal generator to determine the probe's frequency response. The plasmoid electron number density n(sub e) electron temperature T(sub e), and velocity ratio v/c(sub m), (where v is the bulk plasma flow velocity and c(sub m), is the ion thermal speed) have also been measured with a quadruple Langmuir probe. The Langmuir probe tips are 10 mm long, 20-mil diameter stainless steel wire, housed in a 6-inch long 4-bore aluminum rod. Measurements on PTX with argon and hydrogen from the magnetic field probes and quadruple Langmuir probe will be presented in this paper.

Koelfgen, Syri J.↗

Frequency Analyzed Laser Light Scattering (Falls)

A simple and robust light scattering technique for spray diagnostics was developed. The technique provides a spray's intact length and breakup frequency. Scattered light is collected from a laser sheet that illuminates a portion of the spray. The scattered light is imaged on a fast photodiode whose output is sampled at 20 kHz. Fast Fourier transform (FFT) analysis is performed on the sampled signal. The shape of the FFT produced can be correlated to one of three distinct spray regimes: intact sheet, ligaments, or droplets. Strobe and laser illuminated photographs are also shown for reference.

Rhys, Noah O.↗

A Simplified Pattern Match Algorithm for Star Identification

A true pattern matching star algorithm similar in concept to the Van Bezooijen algorithm is implemented using an iterative approach. This approach allows for a more compact and simple implementation which can be easily adapted to be either an all-sky, no a priori algorithm or a follow on to a direct match algorithm to distinguish between ambiguous matches. Some simple analysis is shown to indicate the likelihood of mis-identifications. The performance of the algorithm for the all-sky, no a priori situation is detailed assuming he SKYMAP star catalog describes the true sky. The impact of errors and omissions in the SKYMAP catalog on performance are investigated. In addition, differing levels of noise in the star observations are assumed and results shown. The implications for possible implementation on-board spacecraft are discussed.

Lee, Michael H.↗

A gyroscope calibration analysis for the Gamma Ray Observatory (GRO)

Current documentation and software do not adequately address the calculation and use of the optimal weight matrices involved in calibrating inertial reference units (IRU). Several facets of the GRO IRU calibration as it relates to the bias and misalignment weighting matrices are investigated. The physical meaning and use of the bias and misalignment weight matrices in IRU calibration are examined. The relation of the weighting and the final biases, misalignments, and their corrections are pursued. Methods for determining reliable, realistic weighting matrices to be used in the GRO IRU calibration (IRUCAL) utility are determined. Possible correlations among observation uncertainties are also explored. For the undetermined case where the maneuvers are insufficient to identify all calibration parameters, the weighting matrices allow as much information as possible to be extracted from the measurements. Finally, applicable simulated flight data are used, incorporating the appropriate calibration maneuvers, to test the weighting matrices in the IRUCAL utility, and examine correlation effects.

Ketchum, Eleanor A.↗