Engineering Papers⌕ Search

Engineering topics

Lee, H.

Publications and source records attributed to Lee, H..

At least 55 records · Page 3

Band Dependent Interlayer f -Electron Hybridization in CeRhIn 5

A key issue in heavy fermion research is how subtle changes in the hybridization between the 4 f (5 f ) and conduction electrons can result in fundamentally different ground states. CeRhIn 5 stands out as a particularly notable example: when replacing Rh with either Co or Ir, antiferromagnetism gives way to superconductivity. In this photoemission study of CeRhIn 5 , we demonstrate that the use of resonant angle-resolved photoemission spectroscopy with polarized light allows us to extract detailed information on the 4 f crystal field states and details on the 4 f and conduction electron hybridization, which together determine the ground state. We directly observe weakly dispersive Kondo resonances of f electrons and identify two of the three Ce4 f $^{1}_{5/2}$ crystal-electric-field levels and band-dependent hybridization, which signals that the hybridization occurs primarily between the Ce 4 f states in the CeIn 3 layer and two more three-dimensional bands composed of the Rh 4 d and In 5 p orbitals in the RhIn 2 layer. Our conclusions allow us to connect the properties observed at elevated temperatures with the unusual low-temperature properties of this enigmatic heavy fermion compound.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct observation of a two-dimensional hole gas at oxide interfaces

The discovery of a two-dimensional electron gas (2DEG) at the LaAlO 3 /SrTiO 3 interface has resulted in the observation of many properties not present in conventional semiconductor heterostructures, and so become a focal point for device applications. Its counterpart, the two-dimensional hole gas (2DHG), is expected to complement the 2DEG. However, although the 2DEG has been widely observed, the 2DHG has proved elusive. Here in this paper we demonstrate a highly mobile 2DHG in epitaxially grown SrTiO 3 /LaAlO 3 /SrTiO 3 heterostructures. Using electrical transport measurements and in-line electron holography, we provide direct evidence of a 2DHG that coexists with a 2DEG at complementary heterointerfaces in the same structure. First-principles calculations, coherent Bragg rod analysis and depth-resolved cathodoluminescence spectroscopy consistently support our finding that to eliminate ionic point defects is key to realizing a 2DHG. Lastly, the coexistence of a 2DEG and a 2DHG in a single oxide heterostructure provides a platform for the exciting physics of confined electron-hole systems and for developing applications.

36 MATERIALS SCIENCE↗

Particle damage sources for fused silica optics and their mitigation on high energy laser systems

High energy laser systems are ultimately limited by laser-induced damage to their critical components. This is especially true of damage to critical fused silica optics, which grows rapidly upon exposure to additional laser pulses. Much progress has been made in eliminating damage precursors in as-processed fused silica optics (the advanced mitigation process, AMP3), and very high damage resistance has been demonstrated in laboratory studies. However, the full potential of these improvements has not yet been realized in actual laser systems. In this work, we explore the importance of additional damage sources–in particular, particle contamination–for fused silica optics fielded in a high-performance laser environment, the National Ignition Facility (NIF) laser system. We demonstrate that the most dangerous sources of particle contamination in a system-level environment are laser-driven particle sources. In the specific case of the NIF laser, we have identified the two important particle sources which account for nearly all the damage observed on AMP3 optics during full laser operation and present mitigations for these particle sources. Finally, with the elimination of these laser-driven particle sources, we demonstrate essentially damage free operation of AMP3 fused silica for ten large optics (a total of 12,000 cm 2 of beam area) for shots from 8.6 J/cm 2 to 9.5 J/cm 2 of 351 nm light (3 ns Gaussian pulse shapes). Potentially many other pulsed high energy laser systems have similar particle sources, and given the insight provided by this study, their identification and elimination should be possible. The mitigations demonstrated here are currently being employed for all large UV silica optics on the National Ignition Facility

36 MATERIALS SCIENCE↗

Rb based alkali antimonide high quantum efficiency photocathodes for bright electron beam sources and photon detection applications

In this paper, high quantum efficiency alkali antimonide photocathodes have been grown over both stainless steel and glass substrates using sequential evaporation of Sb, K, Rb, and Cs. Quantum efficiencies well above 25% have been measured at 400 nm. Finally, a bi-alkali Rb-K-Sb photocathode grown on a stainless steel substrate has been installed in a high voltage DC gun at Cornell University and the intrinsic electron beam emittance was measured at different photon energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra low emittance electron beams from multi-alkali antimonide photocathode operated with infrared light

The intrinsic emittance of electron beams generated from a multi-alkali photocathode operated in a high voltage DC gun is reported. The photocathode showed sensitivity extending to the infrared part of the spectrum up to 830 nm. The measured intrinsic emittances of electron beams generated with light having wavelength longer than 800 nm are approaching the limit imposed by the thermal energy of electrons at room temperature with quantum efficiencies comparable to metallic photocathodes used in operation of modern photoinjectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Remote monitoring of Alpha Gamma hot cell facility by ARG-US RFID system - 15177

Argonne National Laboratory (Argonne) has developed a monitoring and tracking system for nuclear materials based on radio frequency identification (RFID) technology. The system, called ARG-US ('Watchful Guardian'), has been in fielding testing and applications at selected U.S. Department of Energy (DOE) sites since 2010. ARG-US utilizes battery-powered tags to remotely and continuously monitor the environmental parameters, e.g., radiation levels, of the tagged items such as containers of radioactive materials. To demonstrate that the system can monitor nuclear and radiological facilities as well, a compact system was installed in the Alpha Gamma Hot Cell Facility (AGHCF) at Argonne in 2013. AGHCF is a Hazard Category 2 non-reactor nuclear facility that is being decommissioned. It is also being used to support de-inventory of other facilities on the Argonne site. As such, large quantities of radioactive materials and wastes are being discharged from the hot cell, loaded into transport containers, and shipped away. The deployed ARG-US system monitors worker areas, material transfer areas, cell exhaust HEPA filters, and?on a rover/robot?in-cell locations of AGHCF. Thus far, the system is performing as designed and yielding results that can be corroborated by existing surveillance means. The in-cell unit is particularly valuable, as it yields information that would otherwise be hard to obtain. In time, the benefits of automated monitoring 24/7 by ARG-US should become apparent and may lead to a fuller system with more distributed tags in the hot cell areas until the facility is fully decommissioned. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface segregation and oxidation of Pt 3 Ni(1 1 1) alloys under oxygen environment

Utilizing ambient pressure X-ray photoelectron spectroscopy (AP-XPS), the surface segregation and oxidation of Pt 3 Ni(1 1 1) alloys are investigated as a function of temperature and oxygen pressure. The in situ AP-XPS measurements of oxygen oxidation process show that the Pt “skin” surface is not stable under the exposure of oxygen pressure of 100 mTorr at room temperature. As the temperature and pressure are elevated, the formations of Ni 2 O 3 , NiO x , and NiO are observed on surface while Pt atom starts to reduce its adsorbed oxygen, which is a clear sign of surface segregation of Ni to surface. Upon the evacuation of oxygen gas, i.e. ultrahigh vacuum condition, both of NiO x and NiO oxide get reduced and Ni 2 O 3 remains on the surface. Finally, the DFT calculation is employed to explain the formation of surface oxides under oxidation condition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of pion production in eA with the CLAS detector

Preliminary results on semi-inclusive charged pion production in eA collisions at E{sub beam}=5 GeV/c{sup 2} are presented. The data were collected using the CLAS detector, which is a multipurpose, large acceptance, magnetic spectrometer located in Hall B at the Thomas Jefferson National Accelerator Facility. Selected distributions in W, Q{sup 2}, p{sub π}, and θ{sub π} are shown for data produced using deuterium, carbon, iron and lead targets. Preliminary comparisons with data simulated using the GENIE generator are made. The motivation for this work is to provide distributions useful for tuning the hadronic final state interaction models in order to reduce uncertainties in the results extracted from current and next-generation neutrino oscillation experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bottom-Up Cost Analysis of a High Concentration PV Module; NREL (National Renewable Energy Laboratory)

We present a bottom-up model of III-V multi-junction cells, as well as a high concentration PV (HCPV) module. We calculate $0.65/Wp(DC) manufacturing costs for our model HCPV module design with today’s capabilities, and find that reducing cell costs and increasing module efficiency offer the promising pathways for future cost reductions. Cell costs could be significantly reduced via an increase in manufacturing scale, substrate reuse, and improved manufacturing yields. We also identify several other significant drivers of HCPV module costs, including the Fresnel lens primary optic, module housing, thermal management, and the receiver board. These costs could potentially be lowered by employing innovative module designs.

$/W↗

Direct evidence of anomalous interfacial magnetization in metamagnetic Pd doped FeRh thin films

Palladium doped iron rhodium is a magnetic material of significant interest for it’s close to room temperature magnetostructural phase transition from antiferromagnetic (AF) to ferromagnetic (FM) ordering. Here we report on the peculiarities of the magnetization distribution in thin films of FeRh(Pd) probed by Polarized Neutron Reflectometry. Remarkably, we’ve found thin interfacial regions with strong magnetization that have unique thermomagnetic properties as compared to the rest of the system. These regions exist at the top and bottom interfaces of the films while the central regions behave similarly to the bulk with a clear AF-FM order transition. Further we explore the impact of an additional Pt interlayer introduced in the middle of the FeRh(Pd) film and reveal that it serves to replicate the strong interfacial magnetization found at the top and bottom interfaces. In conclusion, these results are of great value both in understanding the fundamental physics of such an order transition, and in considering FeRh(Pd) for magnetic media and spintronics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray diagnostic developments in the perspective of DEMO

Soft X-ray diagnostics at present are not adequate for a burning plasma experiment, neither in term of hardware nor as diagnostic conception. Detectors have to be radiation tolerant, easily shielded, with low sensitivity to neutrons and gammas and with energy discrimination. Layout and viewing capability should be more flexible, thanks to the use also of optical devices, going toward a configuration intermediate between discrete tomography and pure imaging. The general conception of these diagnostics should therefore evolve in the direction of pattern recognition for a real time feedback. This work is focused on the diagnostic developments undertaken at the ENEA- Frascati X-ray Laboratory, following in particular three directions: gas detector for fast and advanced high density tomography, C-MOS solid state imaging detectors for slow control and X-ray polycapillary optics. GEM gas detectors in photon counting mode (noise free) were developed in the range 1-30 keV having high efficiency, high time resolution (up to microseconds), energy discrimination in bands and optical flexibility. Discrimination of X-rays, neutrons and gammas has been demonstrated, thanks to the combination of intrinsic gain and discrimination thresholds, at neutron fluxes (10{sup 7} n/s*cm{sup 2}) comparable with the expected ones at the ports of ITER. GEM detectors are also extremely flexible in the design, allowing optimization of the measurements and solutions for shielding or minimization of the effect of background radiation. Two solid state C-MOS imagers working in photon counting mode, one based on Si semiconductor (Medipix-2, range 5-30 keV) and the other one having a CdTe sensor (Pixirad, range 2-100 keV) have been characterized in laboratory. C-MOS imagers have features and performances thoroughly complementary to the GEM detector and, thanks to their higher pixel density, could be used as remote imaging detectors coupled to optics. X-ray polycapillary lenses have been therefore studied in the laboratory both as imaging optical device (full lens) or to define a line of sight (cylinder lens); the preliminary results are encouraging toward the goal of using these lenses to transport X-ray radiation far from the reactor. Reflective or diffractive X-ray optics can be also an option for tomography. A GEM detector has been installed at KSTAR and in the next future hopefully the other approaches will be tested there: once their feasibility will be demonstrated, the issue of the improvement of the radiation tolerance will be faced and the development of algorithms for data analysis as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-16: Reproducibility of Computed Tomography Quantitative Structural Features Using the FDA Thoracic Phantom Image Database

Purpose: To assess the reproducibility of quantitative structural features using images from the computed tomography thoracic FDA phantom database under different scanning conditions. Methods: Development of quantitative image features to describe lesion shape and size, beyond conventional RECIST measures, is an evolving area of research in need of benchmarking standards. Gavrielides et al. (2010) scanned a FDA-developed thoracic phantom with nodules of various Hounsfield units (HU) values, shapes and sizes close to vascular structures using several scanners and varying scanning conditions/parameters; these images are in the public domain. We tested six structural features, namely, Convexity, Perimeter, Major Axis, Minor Axis, Extent Mean and Eccentricity, to characterize lung nodules. Convexity measures lesion irregularity referenced to a convex surface. Previously, we showed it to have prognostic value in lung adenocarcinoma. The above metrics and RECIST measures were evaluated on three spiculated (8mm/-300HU, 12mm/+30HU and 15mm/+30HU) and two non-spiculated (8mm/+100HU and 10mm/+100HU) nodules (from layout 2) imaged at three different mAs values: 25, 100 and 200 mAs; on a Phillips scanner (16-slice Mx8000-IDT; 3mm slice thickness). The nodules were segmented semi-automatically using a commercial software tool; the same HU range was used for all nodules. Results: Analysis showed convexity having the lowest maximum coefficient of variation (MCV): 1.1% and 0.6% for spiculated and non-spiculated nodules, respectively, much lower compared to RECIST Major and Minor axes whose MCV were 10.1% and 13.4% for spiculated, and 1.9% and 2.3% for non-spiculated nodules, respectively, across the various mAs. MCVs were consistently larger for speculated nodules. In general, the dependence of structural features on mAs (noise) was low. Conclusion: The FDA phantom CT database may be used for benchmarking of structural features for various scanners and scanning conditions; we used only a small fraction of available data. Our feature convexity outperformed other structural features including RECIST measures.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-17: Dependence of 3D/4D PET Quantitative Image Features On Noise

Purpose: Quantitative imaging is a fast evolving discipline where a large number of features are extracted from images; i.e., radiomics. Some features have been shown to have diagnostic, prognostic and predictive value. However, they are sensitive to acquisition and processing factors; e.g., noise. In this study noise was added to positron emission tomography (PET) images to determine how features were affected by noise. Methods: Three levels of Gaussian noise were added to 8 lung cancer patients PET images acquired in 3D mode (static) and using respiratory tracking (4D); for the latter images from one of 10 phases were used. A total of 62 features: 14 shape, 19 intensity (1stO), 18 GLCM textures (2ndO; from grey level co-occurrence matrices) and 11 RLM textures (2ndO; from run-length matrices) features were extracted from segmented tumors. Dimensions of GLCM were 256×256, calculated using 3D images with a step size of 1 voxel in 13 directions. Grey levels were binned into 256 levels for RLM and features were calculated in all 13 directions. Results: Feature variation generally increased with noise. Shape features were the most stable while RLM were the most unstable. Intensity and GLCM features performed well; the latter being more robust. The most stable 1stO features were compactness, maximum and minimum length, standard deviation, root-mean-squared, I30, V10-V90, and entropy. The most stable 2ndO features were entropy, sum-average, sum-entropy, difference-average, difference-variance, difference-entropy, information-correlation-2, short-run-emphasis, long-run-emphasis, and run-percentage. In general, features computed from images from one of the phases of 4D scans were more stable than from 3D scans. Conclusion: This study shows the need to characterize image features carefully before they are used in research and medical applications. It also shows that the performance of features, and thereby feature selection, may be assessed in part by noise analysis.

60 APPLIED LIFE SCIENCES↗