Engineering PapersSearch

Engineering topics

Lawing, P. L.

Publications and source records attributed to Lawing, P. L..

At least 19 records

Flow diagnostics and visualization in wind tunnels and flight

The Langley Research Center has a concentrated and directed effort under way to develop both conventional and non-intrusive diagnostic instrumentation. These instruments are being developed to operate over large Mach number, total temperature, and total pressure ranges. Efforts are being made to evaluate the measurements made by the various instruments to determine the most accurate and reliable instrument to be used under a given flow environment. Although only one flow visualization technique was described, there are many different types presently being used at Langley Research Center.

Stainback, P. C.

Cryogenic wind tunnels for high Reynolds number testing

A compilation of lectures presented at various Universities over a span of several years is discussed. A central theme of these lectures has been to present the research facility in terms of the service it provides to, and its potential effect on, the entire community, rather than just the research community. This theme is preserved in this paper which deals with the cryogenic transonic wind tunnels at Langley Research Center. Transonic aerodynamics is a focus both because of its crucial role in determining the success of aeronautical systems and because cryogenic wind tunnels are especially applicable to the transonics problem. The paper also provides historical perspective and technical background for cryogenic tunnels, culminating in a brief review of cryogenic wind tunnel projects around the world. An appendix is included to provide up to date information on testing techniques that have been developed for the cryogenic tunnels at Langley Research Center. In order to be as inclusive and as current as possible, the appendix is less formal than the main body of the paper. It is anticipated that this paper will be of particular value to the technical layman who is inquisitive as to the value of, and need for, cryogneic tunnels.

Lawing, P. L.

Wall shear stress measurements using a new transducer

A new instrument has been developed for direct measurement of wall shear stress. This instrument is simple and symmetric in design with small moving mass and no internal friction. Features employed in the design of this instrument eliminate most of the difficulties associated with the traditional floating element balances. Vibration problems associated with the floating element skin friction balances have been found to be minimized by the design features and optional damping provided. The unique design of this instrument eliminates or reduces the errors associated with conventional floating-element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Measurement made in three different tunnels show good agreement with theory and data obtained by the floating element devices.

Vakili, A. D.

Summary of test techniques used in the NASA Langley 0.3-meter Transonic Cryogenic Tunnel

This paper describes test techniques used to obtain data in the 0.3-m Transonic Cryogenic Tunnel. Main sections include steady aerodynamic testing, unsteady aerodynamics, non-intrusive measurements, tunnel performance, and fluid mechanics. Test techniques with adequate previous documentation are briefly presented and referenced, and those for which no documentation yet exists are more thoroughly discussed. Attention is given to the model building and instrumentation technology necessary for testing at high Reynolds numbers in the presence of free transition. It is concluded that the testing techniques thus far demonstrated in the 0.3-m TCT are on par with modern transonic tunnels, and that the specialized techniques needed to exploit the advantages of cryogenic operation can be realized.

Lawing, P. L.

The construction of airfoil pressure models by the plate method: Achievements, current research, technology development and potential applications

A method of constructing airfoils by inscribing pressure channels on the face of opposing plates, bonding them together to form one plate with integral channels, and contour machining this plate to form an airfoil model is described. The research and development program to develop the bonding technology is described as well as the construction and testing of an airfoil model. Sample aerodynamic data sets are presented and discussed. Also, work currently under way to produce thin airfoils with camber is presented. Samples of the aft section of a 6 percent airfoil with complete pressure instrumentation including the trailing edge are pictured and described. This technique is particularly useful in fabricating models for transonic cryogenic testing, but it should find application in a wide ange of model construction projects, as well as the fabrication of fuel injectors, space hardware, and other applications requiring advanced bonding technology and intricate fluid passages.

Lawing, P. L.

Measurements in the flow field of a cylinder with a laser transit anemometer and a drag rake in the Langley 0.3 m transonic cryogenic tunnel

An experiment was conducted at the 0.3 m Transonic Cryogenic Tunnel using a Laser Transit Anemometer (LTA) to probe the flow field around a 3.05 centimeter-diameter circular cylinder. Measurements were made along the stagnation line and determination of particle size was evaluated by their ability to follow the flow field. The LTA system was also used to scan into the boundary layer near the 45 degree point on the model. Results of these scans are presented in graphic and tabular form. Flow field particle seeding was accomplished by inbleeding dry service air. The residual moisture (5-10 ppm) condensed and formed ice particles which served as Mie scattering centers for the LTA detection system. Comparison of data taken along the stagnation streamline with theory indicated that these particles tracked the velocity gradient of the flow. Tunnel operating conditions for the tests were a Mach number of 0.3, a pressure of 1.93 x 100000 n/m squared, and a temperature of 225 degrees K. Free stream Mach number and pressure were varied for the particle size determination.

Honaker, W. C.

Description of the insulation system for the Langley 0.3-Meter Transonic Cryogenic Tunnel

The thermal insulation system of the Langley 0.3 Meter Transonic Cryogenic Tunnel is described. The insulation system is designed to operate from room temperature down to about 77.4 K, the temperature of liquid nitrogen at 1 atmosphere. A detailed description is given of the primary insulation sytem consists of glass fiber mats, a three part vapor barrier, and a dry positive pressure purge system. Also described are several secondary insulation systems required for the test section, actuators, and tunnel supports. An appendix briefly describes the original insulation system which is considered inferior to the one presently in place. The time required for opening and closing portions of the insulation system for modification or repair to the tunnel has been reduced, typically, from a few days for the original thermal insulating system to a few hours for the present system.

Lawing, P. L.

An external insulation system for a cryogenic wind tunnel

The thermal insulation system of the 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT) at the NASA Langley Research Center is described in text, photographs, and drawings. The system is designed to operate from room temperature down to about 77.4 K, the temperature of liquid nitrogen at 1 atmosphere. A detailed description is given of the primary insulation system which consists of glass fiber mats, a 3-part vapor barrier, and a dry nitrogen positive-pressure purge system. Also described are several secondary insulation systems required for the test section, actuators, and tunnel supports. An appendix briefly describes the original insulation system which is considered inferior to the one presently in place. Time required for opening and closing portions of the insulation system for modification or repair to the tunnel has been reduced, typically, from a few days for the original thermal insulating system to a few hours for the present system.

Dress, D. A.

Support interference of wind tunnel models: A selective annotated bibliography

This bibliography, with abstracts, consists of 143 citations arranged in chronological order by dates of publication. Selection of the citations was made for their relevance to the problems involved in understanding or avoiding support interference in wind tunnel testing throughout the Mach number range. An author index is included.

Tuttle, M. H.

Effect of upstream sidewall boundary layer removal on an airfoil test

Sidewall boundary layer effects were investigated by applying partial upstream sidewall boundary layer removal in the Langley 0.3-m transonic cryogenic tunnel. Over the range of sidewall boundary layer displacement thickness of these tests the influence on pressure distribution was found to be small for subcritical conditions; however, for supercritical conditions the shock position was affected by the sidewall boundary layer. For these tests (with and without boundary layer remove) comparisons with predictions of the GRUMFOIL computer code indicated that Mach number corrections due to the sidewall boundary layer improve the agreement for both subcritical and supercritical conditions. The results also show that sidewall boundary layer removal reduces the magnitude of the sidewall correction; however, a suitable correction must still be made.

Johnson, C. B.

Flow rate/pressure drop data gathered from testing a sample of the Space Shuttle Strain Isolation Pad (SIP): Effects of ambient pressure combined with tension and compression conditions

Tests were conducted on a sample of strain isolation pad (SIP) typical of that used in the shuttle orbiter thermal protection system to determine the characteristics of SIP internal flow. Data obtained were pressure drop as a function of flow rate for a range of ambient pressures representing various points along the Shuttle trajectory and for stretched and compressed conditions of the SIP. Flow was in the direction of the weave parallel to most of the fibers. The data are plotted in several standard engineering formats in order to be of maximum utility to the user. In addition to providing support to the Space Shuttle Program, these data are a source of experimental information on flow through fiberous (rather than the more usual sand bed type) porous media.

Springfield, R. D.

Studies of sidewall boundary layer in the Langley 0.3 meter transonic cryogenic tunnel with and without suction

Boundary layer measurements on the sidewalls of the Langley 0.3 Meter Transonic Cryogenic Tunnel were made to determine the effectiveness of the passive boundary layer bleed system over a Reynolds number range from 20 to 200 x 10 to the sixth power per meter at Mach numbers from 0.30 to 0.76. The tunnel sidewall boundary layer displacement thickness was about 2 percent of the width of the test section without the boundary layer bleed. Measured velocity profiles correlated well with the defect law of Hama. With the boundary layer bleed equivalent to about 2 percent of the test section mass flow, the boundary layer displacement thickness reduced to about 1 percent of the test section width, which is generally considered acceptable for testing airfoils. It was also noticed that effectiveness of the bleed was nearly independent of the Mach number and Reynolds number over the range of conditions tested. A comparison of the measured suction effectiveness of the bleed with the finite difference and integral methods of boundary layer calculation showed good agreement.

Murthy, A. V.

Investigation of the effects of upstream sidewall boundary-layer removal on a supercritical airfoil

Sidewall boundary-layer effects have been investigated by applying partial upstream sidewall boundary-layer removal in the Langley 0.3-m Transonic Cryogenic Tunnel. Over the range of sidewall boundary-layer displacement thickness of these tests the influence on pressure distributions was found to be small for subcritical conditions; however, for supercritical conditions the shock position was affected by the sidewall boundary layer. For these tests, with and without boundary-layer removal, comparisons with predictions of the GRUMFOIL computer code indicated that Mach number corrections due to the sidewall boundary layer improves the agreement for both subcritical and supercritical conditions. The results show the necessity for accounting for sidewall effects even when the top and bottom wall effects are small.

Murthy, A. V.

Increasing Metal Fracture Toughness

In technique developed at Langley Research Center several thin sheets of metal are diffusion-brazed together in vacuum furnace to create thick piece of metal that retains much of fracture toughness of its thin components. Technique is expected to make many of high-strength stainless steels, not currently suitable, usable at cryogenic temperatures.

Lawing, P. L.

Recent sidewall boundary-layer investigations with suction in the Langley 0.3-m Transonic Cryogenic Tunnel

An experimental and theoretical study of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) sidewall boundary-layer with and without suction, has been made. Without suction, the boundary-layer displacement thickness at a station ahead of the model varied from about 1.6 mm to 1.3 mm over a Reynolds number range of 20 million to 200 million per m at Mach numbers from 0.30 to 0.76. Measured velocity profiles were correlated using the defect law of Hama. The boundary-layer displacement thickness decreased when suction was applied; however, after suction of about 2 percent of test section mass flow, the change in the thickness was small. A comparison of the measured suction effectiveness with finite difference and integral methods of boundary-layer calculation showed that both methods predicted the right trend over the range of suction velocities (up to a suction to free-stream velocity ratio of -0.02).

Murthy, A. V.

Model experience in the Langley 0.3-m transonic cryogenic tunnel

The model building, development, and testing experience gained during 8 years of operation of the 0.3-m Transonic Cryogenic Tunnel (TCT) is summarized. The summary is divided into four portions: (1) models tested in the 0.3-m TCT's original octagonal test section; (2) models tested in the present two dimensional test section; (3) models tested as a part of tunnel calibration and the development of advanced technology airfoils; and (4) development of a new way to construct two dimensional airfoil models. Design requirements imposed on the models by high Reynolds number testing at cryogenic temperatures are reviewed.

Lawing, P. L.

Preliminary results on the development of vacuum brazed joints for cryogenic wind tunnel aerofoil models

The results of initial experiments show that high-strength void-free bonds can be formed by vacuum brazing of stainless steels using copper and nickel-based filler metals. In Nitronic 40, brazed joints have been formed with strengths in excess of the yield strength of the parent metal, and even at liquid nitrogen temperatures the excellent mechanical properties of the parent metal are only slightly degraded. The poor toughness of 15-5 P.H. stainless steel at cryogenic temperatures is lowered even further by the presence of the brazed bonds investigated. It is highly unlikely that the technique would be used for any critical areas of aerofoil models intended for low-temperature service. Nevertheless, the potential advantages of this simplified method of construction still have attractions for use at ambient temperatures.

Wigley, D. A.

Cooling system for high speed aircraft

The system eliminates the necessity of shielding an aircraft airframe constructed of material such as aluminum. Cooling is accomplished by passing a coolant through the aircraft airframe, the coolant acting as a carrier to remove heat from the airframe. The coolant is circulated through a heat pump and a heat exchanger which together extract essentially all of the added heat from the coolant. The heat is transferred to the aircraft fuel system via the heat exchanger and the heat pump. The heat extracted from the coolant is utilized to power the heat pump. The heat pump has associated therewith power turbine mechanism which is also driven by the extracted heat. The power turbines are utilized to drive various aircraft subsystems, the compressor of the heat pump, and provide engine cooling.

Lawing, P. L.