Engineering Papers⌕ Search

Engineering topics

Lasnier, C. J.

Publications and source records attributed to Lasnier, C. J..

Divertor heat load estimates on NSTX and DIII-D using new and open-source 2D inversion analysis code

A thermography inversion algorithm has been developed in the open-source Python-based computer code, HYPERION, to calculate the heat flux incident on plasma-facing components (PFCs) in axisymmetric tokamaks. The chosen mesh size at the surface significantly affects the calculated transient heat flux results. The calculated transient heat flux will exceed the real value when the mesh size tends to zero but will underestimate the real value when the mesh size is large. A criterion for determining the appropriate mesh size for the transient heat flux calculation will be discussed. The numerical scheme for HYPERION uses a 2D fully implicit finite-difference approach, allowing temperature-dependent thermal properties of PFC materials. The inversion algorithm is benchmarked against established heat flux calculation codes, TACO and THEODOR, based on thermography data from NSTX and DIII-D respectively. The primary benefits of HYPERION compared to TACO and THEODOR are that it is open-source and it allows for the optimization of mesh thickness along the substrate. The algorithm also accounts for the thermal properties of thin surface layers that characteristically form on PFCs due to plasma-material interactions. The agreement between HYPERION and THEODOR is excellent, as the percent difference between the codes is ~5% on average in the case of the DIII-D data for moderate to high heat flux. Verification tests with TACO show slightly higher average percent differences of 8% and 12%. In using HYPERION to study filaments in heat flux, the initial results indicate that small ELMs filaments significantly broaden the divertor heat flux, and decrease divertor peak flux. Compared to the inter-ELM, the small ELM filaments decrease the divertor peak surface temperature. With intermittent divertor filaments, the divertor heat flux width is comparable with that found in L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and modeling of type-I and type-II ELMs heat flux to the DIII-D divertor

Type-I and type-II edge-localized-modes (ELMs) heat flux profiles measured at the DIII-D divertor feature a peak in the vicinity of the strike-point and a plateau in the scrape-off-layer (SOL), which extends to the first wall. The plateau is present in attached and detached divertors and it is found to originate with plasma bursts upstream in the SOL. The integrated ELM heat flux is distributed at ~65% in the peak and ~35% in this plateau. The parallel loss model, currently used at ITER to predict power loads to the walls, is benchmarked using these results in the primary and secondary divertors with unprecedented constraints using experimental input data for ELM size, radial velocity, energy, electron temperature and density, heat flux footprints and number of filaments. The model can reproduce the experimental near-SOL peak within ~20%, but cannot match the SOL plateau. Employing a two-component approach for the ELM radial velocity, as guided by intermittent data, the full radial heat flux profile can be well matched. The ELM-averaged radial velocity at the separatrix, which explains profile widening, increases from ~0.2 km s –1 in attached to ~0.8 km s –1 in detached scenarios, as the ELM filaments' path becomes electrically disconnected from the sheath at the target. The results presented here indicate filaments fragmentation as a possible mechanism for ELM transport to the far-SOL and provide evidence on the beneficial role of detachment to mitigate ELM flux in the divertor far-SOL. However, these findings imply that wall regions far from the strike points in future machines should be designed to withstand significant heat flux, even for small-ELM regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of EDGDE2D-EIRENE predicted 2D distributions of electron temperature and density against divertor Thomson scattering measurements in the low-field side divertor leg in DIII-D

Comparisons of profiles of the electron temperature (T e ), density (n e ) and pressure (p e ) measured with Divertor Thomson Scattering in DIII-D low-confinement mode discharges to predictions from the edge fluid code EDGE2D-EIRENE show that the models implemented in EDGE2D-EIRENE predict the measurements within their collective uncertainties if the T e at the separatrix (T e,sep ) is 10 eV, or higher. The simulations do not predict, however, the peaked T e and ne profiles measured adjacent to the target plate when T e,sep , is below 10 eV, i.e., for the plasma downstream from the region of ionization of deuterium atoms. Inclusion of cross-field drifts and a five-fold reduction of radial transport cannot reconcile the discrepancy between the measurements and predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying heat and particle flux to primary and secondary divertors for various types of edge-localized-modes

Between 15% and 30% of edge-localized-mode (ELM) heat flux can be deposited to regions outside the main divertor including the far scrape-off-layer (SOL), private flux region (PFR), and secondary divertor inner target. Analysis shown here demonstrates that type-I and small ELM plasmas are transported to the PFR and to the secondary inner divertor, which is magnetically isolated from the outer divertor, leading to well-defined heat flux profiles and with peak values that can surpass those at the secondary outer target. Such features are consistently observed for pedestal collisionalities from $ν$$^{*}_{e}$ ~1.5 to $ν$$^{*}_{e}$ ~3.9. Heat flux profiles of the examined ELM types feature rippled structures due to bursts in the outer far-SOL region but not on the secondary inner target, causing long decay lengths in the time-averaged ELM profiles. The contribution of each ELM type to the total time-averaged power deposited to the secondary divertor has been evaluated, showing that grassy ELMs contribute ~8%, small ELMs ~67%, and type-I ELMs ~85%. These findings imply that small ELMs may yet pose a concern for future machines if some regions of the main wall are not designed to withstand significant heat and particle fluxes. Due to the low intra-ELM heat flux contribution, however, the grassy ELM regime is an attractive option for an ELMing scenario in future machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlling the size of non-axisymmetric magnetic footprints using resonant magnetic perturbations

The structure of the non-axisymmetric heat load distribution at the divertor plates is determined not only by the toroidal but also from the poloidal spectrum of non-axisymmetric field perturbations. Whether they are intrinsic, like error fields, or they are applied through 3D coils, the non-axisymmetric fields produce complex 3D edge magnetic topologies (footprints) that alter the properties of the heat and particle flux distributions on the divertor target plates. In this manuscript, a study of the impact of applied 3D field poloidal spectrum on the footprint size and structure is done for the DIII-D tokamak using the resistive MHD code M3D-C1 coupled with the field line tracing code TRIP3D. To resolve the impact of the poloidal spectrum of the magnetic perturbation, the relative phase of the two rows of in-vessel 3D coils used to produce both a n = 2 and a n = 3 perturbation is varied, where n is the toroidal harmonic of the magnetic perturbation. This shows that the largest footprint is predicted when the relative phase of the two rows is close to zero, which is also where the resonant coupling with the plasma is maximized. These results suggest that it will be challenging to decouple the footprint size from the requisite resonant coupling for RMP–ELM control. The correlation between the measured heat load and particle flux distributions at the outer divertor plates in DIII-D and the magnetic measurements is in good agreement with the predicted dependence of the magnetic footprint size on the amplitude of the resonant component of the plasma response.

3D fields↗

Micro-trench measurements of the net deposition of carbon impurity ions in the DIII-D divertor and the resulting suppression of surface erosion

In this work, we report carbon impurity ion incident angles and deposition rates, along with silicon erosion rates, from measurements of micro-engineered trenches on a silicon surface exposed to L-mode deuterium plasmas at the DIII-D divertor. Post exposure ex-situ analysis determined elemental maps and concentrations, carbon deposition thicknesses, and erosion of silicon surfaces. Carbon deposition profiles on the trench floor showed carbon ion shadowing that was consistent with ERO calculations of average carbon ion angle distributions (IADs) for both polar and azimuthal angles. Measured silicon net erosion rates negatively correlated with the deposited carbon concentration at different locations. Differential erosion of surfaces on two different ion-downstream trench slope structures suggested that carbon deposition rate is affected by the carbon ion incident angle and significantly suppressed the surface erosion. The results suggest the C impurity ion incident angles, determined by the IADs and surface morphology, strongly affect erosion rates as well as the main ion (D, T, He) incident angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of fully detached divertor integrated with improved core confinement for tokamak fusion plasmas

Integration of divertor detachment with a high-performance (β N ~ 3, β p > 2, H 98 ~ 1.5) core plasma has been demonstrated in DIII-D high-β p (poloidal beta) plasmas associated with a sustained core internal transport barrier (ITB) and an H-mode edge transport barrier (ETB). Such good core-edge integration has been achieved for both neon and nitrogen seeding, for both favorable and unfavorable B-field directions, independently from the impurity puffing locations, though these variations play important roles on divertor characteristics. Compared to the standard H-mode plasmas, the high-β p plasma exhibits a much wider window of detachment compatible with high confinement core. Fully detached divertor plasmas with low plasma temperature (Te < 5 eV), low particle flux, and low heat flux across the entire divertor target plate were obtained by using nitrogen seeding. This detached high-β p plasma is compatible with a newly developed detachment control system which can help optimize the nitrogen gas flow rate. Several features, i.e., the high edge safety factor in the high-β p scenario, impurity injection, closed divertor and reduced heating power requirement due to the high confinement, facilitate the achievement of full divertor detachment at lower density. Instead of degrading global performance, the divertor detachment facilitates the access to an even stronger ITB at large radius with a relatively weak ETB through self-organized synergy between ITB and ETB, leading to sustained high confinement. The strengthening of the large-radius ITB compensates for the ETB degradation associated with divertor detachment. In addition, a weak ETB naturally has smaller edge localized modes (ELMs). In particular, with neon injection, a long-period no-ELM H-mode phase has been achieved simultaneously with high-performance core and partially detached divertor plasmas. Furthermore, these results demonstrate the possibility of integrating excellent core plasma performance with an effective divertor solution, an essential step toward steady-state operation of reactor-grade plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of full divertor detachment with improved core confinement for tokamak fusion plasmas

Divertor detachment offers a promising solution to the challenge of plasma-wall interactions for steady-state operation of fusion reactors. Here, we demonstrate the excellent compatibility of actively controlled full divertor detachment with a high-performance (β N ~ 3, H 98 ~ 1.5) core plasma, using high-β p (poloidal beta, β p > 2) scenario characterized by a sustained core internal transport barrier (ITB) and a modest edge transport barrier (ETB) in DIII-D tokamak. The high-β p high-confinement scenario facilitates divertor detachment which, in turn, promotes the development of an even stronger ITB at large radius with a weaker ETB. This self-organized synergy between ITB and ETB, leads to a net gain in energy confinement, in contrast to the net confinement loss caused by divertor detachment in standard H-modes. These results show the potential of integrating excellent core plasma performance with an efficient divertor solution, an essential step towards steady-state operation of reactor-grade plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of divertor material on neutral recycling and discharge fueling in DIII-D

We report that experiments with the lower divertor of DIII-D during the Metal Rings Campaign (MRC) show that the fraction F of atomic D in the total recycling flux is material-dependent and varies through the ELM cycle, which may affect divertor fueling. Between ELMs, F C ~ 10% and FW ~ 40%, consistent with expectations if all atomic recycling is due to reflections. During ELMs, F C increases to 50% and F W to 60%. In contrast, the total D recycling coefficient including atoms and molecules R stays close to unity near the strike point where the surface is saturated with D. During ELMs, R can deviate from unity, increasing during high energy ELM-ion deposition (net D release) and decreasing at the end of the ELM which leads to ability of the target to trap the ELM-deposited D. The increase of R > 1 in response to an increase in ion impact energy Ei has been studied with small divertor target samples using Divertor Materials Evaluation System (DiMES). An electrostatic bias was applied to DiMES to change E i by 90 eV. On all studied materials including C, Mo, uncoated and W-coated TZM (>99% Mo, Ti, and Zr alloy), W, and W fuzz, an increase of E i transiently increased the D yield (and R) by ~10%. On C there was also an increase in the molecular D 2 yield, probably due to ion-induced D 2 desorption. Despite the measured increase in F on W compared to C, attached H-mode shots with OSP on W during MRC did not demonstrate a higher pedestal density. About 8% increase in the edge density could be seen only in attached L-mode scenarios. The difference can be explained by higher D trapping in the divertor and lower divertor fueling efficiency in H- versus L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in DIII-D towards validating divertor power exhaust predictions

In this study, UEDGE simulations highlight the role of cross-field drifts on the onset of detached conditions, and new calibrated divertor vacuum ultra violet (VUV) spectroscopy is used to challenge the predictions of radiative constituents in these simulations. UEDGE simulations for DIII-D H-mode plasmas with the open divertor with the ion ∇B-drift towards the X-point show a bifurcated onset of the low field side (LFS) divertor detachment, consistent with experimentally observed step-like detachment onset (Jaervinen A.E. et al 2018 Phys. Rev. Lett. 121 075001). The divertor plasma in the simulations exhibits hysteresis in upstream separatrix density between attached and detached solution branches. Reducing the drift magnitude by a factor of 3 eliminates the step-like detachment onset in the simulations, confirming the strong role of drifts in the bifurcated detachment onset. When measured local plasma densities and temperatures are within proximity of predicted values in the simulations, there is no shortfall of the local emission of the dominant resonant radiating lines. However, the simulations systematically predict a factor of two lower total integrated radiated power than measured by the bolometer with the difference lost through radial heat flow out of the computational domain. Even though there is no shortfall in the emission of the dominant lines, a shortfall of total radiated power can be caused by underpredicted spatial extent of the radiation front, indicating a potential upstream or divertor transport physics origin for the radiation shortfall, or shortfall of radiated power in the spectrum between the dominant lines. In addition to the underpredicted spatial extent, in detached conditions, the simulations overpredict the peak radiation and dominant carbon lines near the X-point, which can be alleviated by manually increasing divertor diffusivity in the simulations, highlighting the ad hoc cross-field transport as one of the key limitations of the predictive capability of these divertor fluid codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗