Engineering Papers⌕ Search

Engineering topics

Lange, A. E.

Publications and source records attributed to Lange, A. E..

30 records · Page 2

A degree scale anisotropy measurement of the cosmic microwave background near the star Gamma Ursae Minoris

Results from a search for anisotropy in the cosmic microwave background (CMB) are presented from the third flight of the Millimeter-wave Anisotropy experiment. The CMB observation occurred over 1.37 hours and covered a 6.24 sq deg area of the sky where very little foreground emission is expected. Significant correlated structure is observed at 6 and 9/cm. At 12/cm we place an upper limit on the structure. The relative amplitudes at 6, 9, and 12/cm are consistent with a CMB spectrum. The spectrum of the structure is inconsistent with thermal emission from known forms of interstellar dust. Synchrotron and free-free emission would both require unusually flat spectral indices at cm wavelengths in order to account for the amplitude of the observed structure. Although known systematic errors are not expected to contribute significantly to any of the three optical channels, excess sidelobe contamination cannot be definitively ruled out. If all the structure is attributed to CMB anisotropy, a value of the weighted rms of the 6 and 9/cm channels of Delta T/T(CMB) = 4.7 +/- 0.8 x 10 exp -5 (+/- 1 sigma) was measured. If the CMB anisotropy is assumed to have a Gaussian autocorrelation function with a coherence angle of 25 arcmin, then the most probable value is Delta T/T(CMB) = 4.2 +1.7 or -1.1 x 10 exp -5, where the +/- refers to the 95 percent confidence limits.

Gundersen, J. O.↗

Observation of forbidden C II 158 micron emission from the diffuse interstellar medium at high Galactic latitude

We report the first detection of forbidden C II 158 micron line emission from the diffuse interstellar medium at high Galactic latitude. We have measured the integrated line intensity in a 36 arcmin field of view along a triangular scan path in a 5 x 20 deg region in Ursa Major using a rocket-borne, liquid-helium-cooled spectrophotometer. The scan included high-latitude infrared cirrus, molecular clouds, a bright external galaxy, M82, and the H I Hole, which is a region of uniquely low neutral hydrogen column density. Emission from forbidden C II is observed in all regions, and, in the absence of appreciable CO emission, it is well correlated with neutral hydrogen column density. We observe a forbidden C II gas cooling rate which varies from (1.18 +/- 0.4 to 3.25 +/- 0.8) x 10 exp -26 ergs/s/H atom. Regions with CO emission have enhanced forbidden C II line emission over that expected from the correlation with neutral hydrogen column density. We measure a line-to-continuum ratio which varies from 0.002 to 0.008 in comparison with the all-sky average of 0.0082 reported by FIRAS, which is heavily weighted toward the Galactic plane.

Bock, J. J.↗

A dc-coupled, high sensitivity bolometric detector system for the Infrared Telescope in Space

We report the performance of an ac bridge readout system that has been developed for use on the Infrared Telescope in Space which is scheduled for launch in 1994. The ac bridge readout provides excellent dc stability enabling observing strategies well-suited to space-borne observations. The ability to modulate the optical signal slowly allows the use of new, highly sensitive, long time-constant bolometers. At 300 mK, the bolometers have an electrical noise equivalent power of 3 x 10 exp -17 W/sq rt Hz. The total noise of the differential signal, including amplifier noise, is less than 8 x 10 exp -17 W/sq rt Hz at frequencies as low as 35 mHz.

Devlin, M.↗

A bolometric millimeter-wave system for observations of anisotropy in the cosmic microwave background radiation on medium angular scales

We report the performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0 deg 3 min to 3 deg. The system represents a collaborative effort combining a low-background 1 m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3 (90), 6 (180), 9 (270), and 12 (360) cm(exp -1) (GHz). The telescope was flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of Delta(T)/T(sub CMB) is approximately equal to 10(exp -5) with detectors operated at T = 0.3 K.

Fischer, M. L.↗

Design and construction of high-sensitivity, infrared bolometers for operation at 300 mK

The design and construction of 300-mK composite bolometers developed for millimeter-wave astronomical observations are described. Graphite fibers are used as the electrical leads for the thermistor to reduce the thermal conductance and heat capacity associated with the leads. A mechanical suspension made of Nylon fibers provides the required thermal conductance. Electrical noise equivalent powers below 1 x 10 exp -16 W/sq rt Hz have been achieved for detectors with thermal time constants of 11 ms. The detectors were installed in a millimeter-wave photometer and used to perform observations of the cosmic microwave background from a balloonborne platform. The flight performance was consistent with the measured laboratory properties.

Alsop, D. C.↗

A search for anisotrophy in the cosmic microwave background on intermediate angular scales

The results of a search for anisotropy in the cosmic microwave background on angular scales near 1 deg are presented. Observations were simultaneously performed in bands centered at frequencies of 6, 9, and 12 per cm with a multifrequency bolometric receiver mounted on a balloon-borne telescope. The statistical sensitivity of the data is the highest reported to date at this angular scale, which is of critical importance for understanding the formation of structure in the universe. Signals in excess of random were observed in the data. The experiment, data analysis, and interpretation are described.

Alsop, D. C.↗

A bolometric millimeter-wave system for observations of anisotropy in the cosmic microwave background radiation on medium angular scales

The performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0.3 to 3 deg is presented. The system represents a collaborative effort combining a low-background 1-m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3, 6, 9, and 12/cm (90, 180, 270, and 360 GHz). The telescope has been flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of about 0.00001 with detectors operated at 0.3 K.

Fischer, M. L.↗

A millimeter-wave anisotropy experiment (MAX) to search for anisotropy in the cosmic background radiation on medium angular scales

We report preliminary results from two balloon flights of a millimeter-wave telescope designed to measure anisotropy in the cosmic microwave background (CMB) on angular scales from 0.3 to 3 degrees. The receiver used in the first flight, in November 1989, was a dichroic, He-3-cooled bolometric photometer with passbands centered at 3, 6, 9, and 12/cm. The second flight, in July 1990, employed improved bolometric detectors. The 3/cm band was removed in order to increase the efficiency of the remaining bands. Preliminary analysis of the data gives a factor of 3 improvement in sensitivity over the first flight in the 6/cm band. Future plans include a new receiver to provide an additional factor of 5 improvement in sensitivity and a new balloon-borne telescope which is optimized for low-background bolometric detectors at millimeter wavelengths.

Fischer, M. L.↗

Improved low frequency stability of bolometric detectors

An ac bridge readout system has been developed that greatly improves the low-frequency stability of bolometric detectors. The readout can be implemented with a simple circuit appropriate for use in space applications. A matched pair of detectors was used in the readout to achieve system noise within a factor of two of the fundamental noise limit of the detectors at frequencies as low as 10 mHz. The low-frequency stability of the readout system allows slower, more sensitive detectors to be used in many applications, and it facilitates observing strategies that are well suited to spaceborne observations.

Wilbanks, T.↗

An ac bridge readout for bolometric detectors

The authors have developed a bolometer readout circuit which greatly improves the low-frequency stability of bolometric detectors. The circuit uses an ac bias voltage and two matched bolometers and allows stable dc bolometer operation for integration times greater than 10 s. In astronomical applications the readout allows for qualitatively different observation modes (e.g. staring or slow-drift scanning) which are particularly well suited for space observations and for the use of arrays. In many applications the readout can increase sensitivity. The authors present noise spectra for 4He temperature bolometers with no excess noise at frequencies greater than 0.1 Hz. The measured optical responsivity of a bolometer operated with the present readout is the same as that of a bolometer operated with a conventional readout.

Rieke, F. M.↗

Improved fabrication techniques for infrared bolometers

Ion implantation and sputter metallization are used to produce ohmic electrical contacts to Ge:Ga chips. The method is shown to give a high yield of small monolithic bolometers with very little low-frequency noise. It is noted that when one of the chips is used as the thermometric element of a composite bolometer it must be bonded to a dielectric substrate. The thermal resistance of the conventional epoxy bond is measured and found to be undesirably large. A procedure for soldering the chip to a metallized portion of the substrate in such a way as to reduce this resistance is outlined. An evaluation is made of the contribution of the metal film absorber to the heat capacity of a composite bolometer. It is found that the heat capacity of a NiCr absorber at 1.3 K can dominate the bolometer performance. A Bi absorber possesses significantly lower heat capacity. A low-temperature blackbody calibrator is built to measure the optical responsivity of bolometers. A composite bolometer system with a throughput of approximately 0.1 sr sq cm is constructed using the new techniques. The noise in this bolometer is white above 2.5 Hz and is slightly below the value predicted by thermodynamic equilibrium theory.

Lange, A. E.↗

Improved fabrication techniques for infrared bolometers

Techniques are described for producing improved infrared bolometers from doped germanium. Ion implantation and sputter metalization have been used to make ohmic electrical contacts to Ge:Ga chips. This method results in a high yield of small monolithic bolometers with very little low-frequency noise. When one of these chips is used as the thermometric element of a composite bolometer, it must be bonded to a dielectric substrate. The thermal resistance of the conventional epoxy bond has been measured and found to be undesirably large. A procedure for soldering the chip to a metalized portion of the substrate is described which reduced this resistance. The contribution of the metal film absorber to the heat capacity of a composite bolometer has been measured. The heat capacity of a NiCr absorber at 1.3 K can dominate the bolometer performance. A Bi absorber has significantly lower heat capacity. A low temperature blackbody calibrator has been built to measure the optical responsivity of bolometers. A composite bolometer system with a throughput of approx. 0.1 sr sq cm was constructed using the new techniques. In negligible background it has an optical NEP of 3.6 10((exp -15) W/sq root of Hz at 1.0 K with a time constant of 20 ms. The noise in this bolometer is white above 2.5 Hz and is somewhat below the value predicted by thermodynamic equilibrium theory. It is in agreement with calculations based on a recent nonequilibrium theory.

Lange, A. E.↗