Engineering Papers⌕ Search

Engineering topics

Lane, T. J.

Publications and source records attributed to Lane, T. J..

Mechanism and dynamics of fatty acid photodecarboxylase

Photoenzymes are rare biocatalysts driven by absorption of a photon at each catalytic cycle; they inspire development of artificial photoenzymes with valuable activities. Fatty acid photodecarboxylase (FAP) is a natural photoenzyme that has potential applications in the bio-based production of hydrocarbons, yet its mechanism is far from fully understood. RATIONALE To elucidate the mechanism of FAP, we studied the wild-type (WT) enzyme from Chlorella variabilis (CvFAP) and variants with altered active-site residues using a wealth of techniques, including static and time-resolved crystallography and spectroscopy, as well as biochemical and computational approaches. RESULTS A 1.8-Å-resolution CvFAP x-ray crystal structure revealed a dense hydrogen-bonding network positioning the fatty acid carboxyl group in the vicinity of the flavin adenine dinucleotide (FAD) cofactor. Structures solved from free electron laser and low-dose synchrotron x-ray crystal data further highlighted an unusual bent shape of the oxidized flavin chromophore, and showed that the bending angle (14°) did not change upon photon absorption (step 1) or throughout the photocycle. Calculations showed that bending substantially affected the energy levels of the flavin. Structural and spectroscopic analysis of WT and mutant proteins targeting two conserved active-site residues, R451 and C432, demonstrated that both residues were crucial for proper positioning of the substrate and water molecules and for oxidation of the fatty acid carboxylate by 1 FAD* (~300 ps in WT FAP) to form FAD ∙– (step 2). Time-resolved infrared spectroscopy demonstrated that decarboxylation occured quasi-instantaneously upon this forward electron transfer, consistent with barrierless bond cleavage predicted by quantum chemistry calculations and with snapshots obtained by time-resolved crystallography. Transient absorption spectroscopy in H 2 O and D 2 O buffers indicated that back electron transfer from FAD ∙– was coupled to and limited by transfer of an exchangeable proton or hydrogen atom (step 3). Unexpectedly, concomitant with FAD ∙– reoxidation (to a red-shifted form FAD RS ) in 100 ns, most of the CO 2 product was converted, most likely into bicarbonate (as inferred from FTIR spectra of the cryotrapped FAD RS intermediate). Calculations indicated that this catalytic transformation involved an active-site water molecule. Cryo-Fourier transform infrared spectroscopy studies suggested that bicarbonate formation (step 4) was preceded by deprotonation of an arginine residue (step 3). At room temperature, the remaining CO 2 left the protein in 1.5 μs (step 4'). The observation of residual electron density close to C432 in electron density maps derived from time-resolved and cryocrystallography data suggests that this residue may play a role in stabilizing CO 2 and/or bicarbonate. Three routes for alkane formation were identified by quantum chemistry calculations; the one shown in the figure is favored by the ensemble of experimental data. CONCLUSION Finally, we provide a detailed and comprehensive characterization of light-driven hydrocarbon formation by FAP, which uses a remarkably complex mechanism including unique catalytic steps. We anticipate that our results will help to expand the green chemistry toolkit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Holographic phase retrieval and reference design

Here, a general mathematical framework and recovery algorithm is introduced for the holographic phase retrieval problem. In this problem, which arises in holographic coherent diffraction imaging, a 'reference' portion of the signal to be recovered via phase retrieval is a priori known from experimental design. A generic formula is additionally derived for the expected recovery error when the measurement data is corrupted by Poisson shot noise. This facilitates an optimization perspective towards reference design and analysis. We employ this optimization perspective towards quantifying the performance of various reference choices.

97 MATHEMATICS AND COMPUTING↗

Electron Ghost Imaging

Here in this paper, we report a demonstration of electron ghost imaging. A digital micromirror device directly modulates the photocathode drive laser to control the transverse distribution of a relativistic electron beam incident on a sample. Correlating the structured illumination pattern to the total sample transmission then retrieves the target image, avoiding the need for a pixelated detector. In our example, we use a compressed sensing framework to improve the reconstruction quality and reduce the number of shots compared to raster scanning a small beam across the target. Finally, compressed electron ghost imaging can reduce both acquisition time and sample damage in experiments for which spatially resolved detectors are unavailable (e.g., spectroscopy) or in which the experimental architecture precludes full frame direct imaging.

43 PARTICLE ACCELERATORS↗