Enhanced Integer Permutation based Genetic Algorithm for Optimization of Tube-Fin Heat Exchanger Circuitry with Splits and Merges

Tube-fin heat exchangers (HXs) are widely used in air-conditioning and heat pump applications. The performance of these heat exchangers is strongly influenced by the refrigerant circuitry. Studies have proved that by optimizing the refrigerant circuitry, the performance of HXs can be significantly improved. In our previous research, an Integer Permutation based Genetic Algorithm (IPGA) was developed to obtain the optimal circuitry designs. Our previous research showed that IPGA demonstrates superior capability to obtain better refrigerant circuitries with lower computational cost than the other methods in literature. And the optimal circuitry designs obtained from IPGA are manufacturable with the available tooling. However, the IPGA developed previously cannot generate designs with splitting and merging of circuits. To remedy this limitation, a new chromosome which can represent circuitry with splitting and merging of circuits is developed. In addition to the six genetic operators implemented previously, two new genetic operators are developed to generate splits and merges. As a result, the enhanced IPGA can explore the solution space more thoroughly than the previous IPGA. A case study using an evaporator from an A-type indoor unit shows that, given the similar capacity improvements obtained from the enhanced IPGA compared with the previous IPGA, the refrigerant pressure drop reduction obtained from the enhanced IPGA is 26.5% compared against 1.0% pressure drop reduction from the previous IPGA. The benchmark of the enhanced IPGA with other methods in literature demonstrates that the enhanced IPGA can generate circuitry designs with performance superior to those obtained from other methods.

LI, Zhenning↗

Model-based Design Optimization to Achieve the Performance Goals (16.0 SEER/9.5 HSPF), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Usage of low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Our research in previous milestone report has shown that using heat exchangers with 5 mm diameter tubes instead of 9 mm diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants. In addition, the 5mm tube heat exchangers can lead to lower system refrigerant charge and as a result, reduce environmental impact further. However, shifting to small tube diameters requires in-depth heat exchanger design optimization to adapt to the transition to low-GWP refrigerants. In the 2nd quarter of FY21, we conducted multi-objective optimizations using Particle Swarm Optimization algorithm on a residential 5-ton air source heat pump to investigate the potential system performance improvements and material savings. 4 low-GWP refrigerants, ARM20A, ARM20B, R454A and R454C are investigated in this study. The objectives of the optimization are to minimize the heat pump material cost and to maximize the system performance simultaneously. As a result, the HXs material cost is reduced by up to 77% according to the copper and aluminum material price in current market. Under heating mode operation, the smart 4-way valve guarantees that the optimal low-GWP systems maintain or outperform the heating performance of the R410A baseline system. The model-based design optimization yields 18.3-18.9 SEER and 10.6-11.9 HSPF for optimal systems using different low-GWP refrigerants. The initial performance goals (16.0 SEER/9.5 HSPF) are achieved. Furthermore, up to 50% system refrigerant charge reduction is possible in the optimized low-GWP heat pump system using ARM20B. And 91%-95% predicted life-time direct CO 2 emission reduction is achieved by using the optimal 5mm tube low-GWP heat pumps. The significant material saving, charge reduction and direct CO 2 emission reduction help in reducing the environmental impacts of heat pump systems. The optimal heat exchangers resulting from this research can fit into the original baseline indoor and outdoor fan-coil unit. This can reduce the retrofitting effort by minimizing the change in manufacturing and installation of the heat pumps and guarantee the compatibility with end-users’ house structure. Finally, the new products can be easily accepted by manufacturers and end-users.

42 ENGINEERING↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗