Kuvin, Sean Andrew

Publications and source records attributed to Kuvin, Sean Andrew.

At least 19 records

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Chlorine Nuclear Data Evaluation Aided Through New LANSCE Measurements

The collaboration between the Los Alamos National Laboratory Neutron Science Center (LANSCE) and TerraPower LLC enables the enhanced understanding of fast spectrum critical systems consisting of chlorine. Specifically, TerraPower is interested in updating the nuclear data for the stable isotopes of chlorine, 35 Cl and 37 Cl, because these nuclides are the primary constituents of the chloride fuel salt in the Molten Chloride Reactor Experiment (MCRE), for which TerraPower is leading the design. The Cooperative Research and Development Agreement (CRADA) between the parties is funded by DOE’s Office of Nuclear Energy’s Gateway for Accelerated Innovation in Nuclear (GAIN) initiative to provide the nuclear community with access to the technical, regulatory, and financial support necessary to motivate innovative nuclear reactor technologies toward commercialization. New measurements of 35 Cl(n,p total ) and 35 Cl(n,Ξ± total ) were completed at LANSCE to constrain the reaction theory models that are used to generate the updated evaluations. The updated evaluations were then tested across the sensitivities of the MCRE by TerraPower to provide direct feedback to the evaluation for application specific sensitivities.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Differential cross sections of the 16 O (𝑛,𝛼) reaction at neutron energies from 3.8 to 15 MeV

The importance of studying the 16 O (𝑛,𝛼) reaction is motivated by multiple nuclear applications which rely on an accurate nuclear reaction data library for oxygen. Discrepancies between past experimental data on the 16 O (𝑛,𝛼) 13 C reaction and its time-reverse 13 C ⁑(𝛼,𝑛) 16 O reaction have led to various different nuclear data evaluations. Here, we have measured 16 O (𝑛,𝛼) reaction cross sections using the LENZ instrument with the unmoderated white neutron source at LANSCE. Results from 2016/2017 data are discussed and used to benchmark the mcnp and geant simulations of the LENZ experimental setup. We report partial differential cross sections of 16 O (𝑛,𝛼 0 ) at 𝐸 𝑛 = 3.8–15 MeV and 16 O ⁑(𝑛,𝛼 1 +𝛼 2 +𝛼 3 ) at 𝐸 𝑛 =9–15 MeV, based on the new measurement in 2021. The resonances that we observed are in good agreement with the levels in 17 O that were previously measured. The LENZ cross sections are in better agreement with the ENDF/B-VIII.0 evaluation than the with reduced cross section found in ENDF/B-VII.1 up to 6 MeV. However, the current results for 16 O ⁑(𝑛,𝛼 0 ) 13 C g.s. appear to be in the best agreement over the entire energy range with that of JENDL/AN-2005 (ENDF/B-VI.0).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrospraying deposition and characterization of potassium chloride targets for nuclear science measurements

Natural and isotopically enriched KCl targets were prepared using specially formulated KCl solutions, deposited by electrospraying on thin (1.5 ΞΌm) gold backings, followed by a short annealing in a preheated (350-450 Β°C) furnace. Various techniques, such as X-ray fluorescence (XRF), scanning electron microscopy (SEM) imaging, and energy-dispersive X-ray spectroscopy (EDS), were used to characterize the produced targets. A white neutron beam at the Los Alamos Neutron Science Center (LANSCE) facility was also used to verify the estimated atomic percentages of the enriched 40 KCl targets. KCl was deposited relatively uniformly as large particles rather than films on the gold surface. As a result, this method can be broadly extended to make stable targets that are difficult to produce with other methods and more exotic radioactive targets required for research in fundamental sciences and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

The LANSCE experimental program: accelerator requirements

The LANSCE accelerator complex exploits a flexible, high power 800 MeV proton linear accelerator to enable a broad swath of experimental work supporting multiple scientific programs. The beam requirements for these programs are diverse and change over time. The purpose of this document is to record, at a high level, the experimental requirements driving the beam delivery requirements for each experimental facility at LANSCE. Revision 0 serves to baseline the current set of experiments, and we expect to revise the document on an as-needed basis when either the experimental requirements change or are found to require a more complete definition.

43 PARTICLE ACCELERATORS↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt Ξ³-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic Ξ³-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Direct measurement of 59 Ni( n, p ) 59 Co and 59 Ni( n, Ξ± ) 56 Fe at fast-neutron energies from 500 keV to 10 MeV

We report nuclear reaction data for neutron induced reactions on unstable nuclei are critical for a wide range of applications spanning studies of nuclear astrophysics, nuclear reactor designs, and radiochemistry diagnostics. However, nuclear data evaluations of the reaction cross sections are largely based on calculations due to the difficulty in performing this class of measurements and the resulting lack of experimental data. For neutron induced charged particle reactions at fast neutron energies, at the MeV scale, these cross section predictions are predominately driven by statistical Hauser-Feshbach calculations. In this work, we present partial and total 59 Ni(n, p) and 59 Ni(n, Ξ±) cross sections, measured directly with a radioactive 59 Ni target, and compare the results to the present nuclear data evaluations. In addition, the results from this work are compared to a recent study of the 59 Ni(n, xp) reaction cross section that was performed via an indirect surrogate ratio method. The expected energy trend of the cross section, based on the current work, is inconsistent with that of the surrogate work. This calls into question the reliability of that application of the surrogate ratio method and highlights the need for direct measurements on unstable nuclei, when feasible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE

A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , Ξ± 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , Ξ± 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonstatistical fluctuations in the 35 Cl(n,p) 35 S reaction cross section at fast-neutron energies from 0.6 to 6 MeV

The lack of experimental data on the 35 Cl(n,p) 35 S reaction above 100 keV has led to nuclear data evaluations that are relatively unconstrained at fast neutron energies. As a result, efforts to explore, develop, and potentially certify next generation reactor designs that incorporate chloride salts as a coolant material have been hindered. Here, we report partial cross section data for the 35 Cl(n,p) 35 S and 35 Cl(n,Ξ±) 32 P reactions at incident neutron energies between 0.6 MeV and 6 MeV. The measurement was performed using the pulsed beam of neutrons at the unmoderated WNR spallation neutron source at the Los Alamos Neutron Science Center, with the outgoing charged particles detected by the LENZ experimental setup, consisting of annular silicon detectors. Nonstatistical fluctuations in the 35 Cl(n,p 0 ) cross section were observed up to around 3 MeV, and the magnitude of the cross section was systematically lower than all available data evaluations at energies above 1 MeV. Modifications to the ENDF/B-VIII.0 data evaluation are suggested to better reproduce the energy averaged experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New evaluation on angular distributions and energy spectra for neutron-induced charged-particle measurements

Recent development on neutron-induced charged particle reaction measurements can provide high-quality double differential cross sections at Los Alamos Neutron Science Center. With newly measured cross section data, we found lacking nuclear outputs for neutron-induced charged particle reactions in the latest ENDF/B-VIII.0 library, when compared with Monte Carlo simulations. Here, this paper presents how we improved the missing angular distributions and energy spectra for these reactions and the validation of our new evaluations with the measurements performed with the LENZ instrument at LANSCE. The impact of this additional evaluation is demonstrated by comparing the MCNP simulations with the LENZ experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—