Engineering Papers⌕ Search

Engineering topics

Kutsaev, S. V.

Publications and source records attributed to Kutsaev, S. V..

Experimental studies of a high-gradient X-band welded hard-copper split accelerating structure

We report on recent research on high-gradient radio frequency (RF) accelerating structures indicates that the use of hard copper alloys provides improvement in high gradient performance over annealed copper. Such structures are made by bonding individually manufactured parts. However, there are no well-established bonding techniques that preserve the hardness, surface finish and cleanliness required for high gradient operation. To preserve the copper hardness, RadiaBeam has developed a novel high-gradient split accelerating structure, based on electron beam welding joining technique. This technique provides efficient bonding with strong, clean welds and minimal thermal loading, while maintaining a clean inner RF environment. Our RF design and fabrication methodology limits the small heat affected zone to the outer cavity envelop, with virtually no distortions or thermal loading of critical RF surfaces. It also incorporates provisions to precisely control the gap despite conventional issues with weld joint shrinkage. To date we have manufactured and validated an RF accelerating structure joined by electron-beam welding that incorporates a novel open split design to significantly reduce the assembly complexity and cost. In this paper, we will present the electromagnetic design of this structure, discuss bonding, and present the results of high-power tests, where the accelerating gradients of 140 MV m -1 with surface peak fields of 400 MV m -1 were achieved for flat-top pulse length of 600 ns with an RF breakdown rate of 10 -4 1/(pulsecm).

43 PARTICLE ACCELERATORS↗

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interposed pulsed power system for fast separation of radioactive beams

This paper presents the novel design of an interposed pulsed power system, developed to drive a fast-switching magnet with a large multi-mH load inductance, and high field amplitude (> 1 T). This modulator can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The system employs a novel over-voltage topology to overcome the inherent inductance and achieve the fast rise and fall times, switching to a precision DC supply to efficiently maintain the flattop without requiring many-kV voltage. We present a power source design consideration, including the results of computer modeling as well as the first experimental results of a modulator scaled test model will also be presented.

47 OTHER INSTRUMENTATION↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Test Results of a High-Gradient 2.856-GHz Negative Harmonic Accelerating Waveguide

We report the high-gradient tests results of a novel traveling wave accelerating structure for β=0.3 based on a novel approach of operating at the first negative spatial harmonic. Accelerating gradients of 50 MV/m and peak electric fields of 160 MV/m were achieved in a single structure consisting of 15 coupled cells during tests at the advanced photon source. This work was performed by RadiaBeam, in collaboration with the Argonne National Laboratory, as a part of a Research and Development Program for the development of an ultrahigh-gradient linear accelerator, the Advanced Compact Carbon Ion Linac, for hadron therapy.

42 ENGINEERING↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Nanosecond rf-Power Switch for Gyrotron-Driven Millimeter-Wave Accelerators

The development of alternative mm-wave high-gradient, >200 MV/m, accelerating structures offers a promising path to reduce the cost and footprint of future TeV-scale linear colliders, as well as linacs for industrial, medical, and security applications. The major factor limiting accelerating gradient is vacuum rf breakdown. The probability of such breakdowns increases with pulse length. For reliable operation, millimeter-wave structures require nanoseconds-long pulses at the megawatt level. This power is available from gyrotrons, which have a minimum pulse length on the order of microseconds. To create shorter pulses and to reliably detect rf breakdowns, we developed the following devices: a laser-based rf switch capable of selecting 10 ns long pulses out of the microseconds long gyrotron pulses, thus enabling the use of the gyrotrons as power sources for mm-wave high-gradient linacs, and a shot-to-shot sub-THz spectrometer with high-frequency resolution, capable of detecting pulse shortening due to rf breakdowns. We will describe the principle of operation of these devices and their achieved parameters. Here, we also report on the experimental demonstration of these devices with the high-power gyrotron at the Massachusetts Institute of Technology. In the experiments, we demonstrate nanosecond rf power modulation, shot-to-shot measurements of the pulse spectra, and detection of rf breakdowns.

43 PARTICLE ACCELERATORS↗

Four-harmonic buncher for radioactive and stable beams switching at the ATLAS facility [Four-harmonic buncher for radioactive and stable beams combination at the ATLAS facility]

Here, the Argonne Tandem Linac Accelerator System (ATLAS) is planning an upgrade to a multi-user facility to simultaneously accelerate both stable beams from an ECR ion source and radioactive beams from an Electron Beam Ion Source charge breeder. The ATLAS Multi-User Upgrade will need to provide high transmission of ion beams with a mass-to-charge ratio up to 7 as it enables more options to alternate radioactive and stable beams. Currently, the bunching is provided with a lumped circuit multi-harmonic buncher, which cannot effectively operate at the required amplitude of the saw-tooth voltage for ions with mass-to-charge ratio of 7 due to thermal issues. RadiaBeam Systems in collaboration with Argonne National Laboratory has designed a four-harmonic coaxial resonator buncher with the ATLAS fundamental frequency of 12.125 MHz, and a compact, less than 2-m-long, footprint, capable of providing the required voltage of 6.2 kV. This device allows fast and reliable pre-bunching of DC ion beams with the capability of fast switching of heavy-ion radioactive and stable beams for delivery to multiple users. In this paper, we will discuss the RF and engineering design considerations of this buncher.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗