Engineering Papers⌕ Search

Engineering topics

Kulisek, Jonathan A.

Publications and source records attributed to Kulisek, Jonathan A..

At least 19 records

Applied radiation tags for warhead dismantlement transparency

Here, this study explores the feasibility of applying radiation tags as a Chain of Custody tool to confirm the dismantlement of individual warheads by investigating time dependent emissions from special nuclear material. Precedents of photon and neutron sources that have been used to irradiate warhead components are presented. Measurements of irradiated Highly Enriched Uranium (HEU) are used to benchmark simulations with the CINDER90 library for MCNP. Delayed gamma emissions are simulated as a function of time since irradiation of moderated HEU and Weapons Grade Plutonium with photon and neutron sources. Models of commercial 9 MV and 15 MV linacs were found to induce ~10 9 fissions/g and ~10 11 fissions/g, respectively, creating 3 to 4 orders of magnitude more delayed gammas than neutron sources, modeled at 10 10 n/s. However, a DT neutron source was found to induce sufficient fissions, ~10 7 fissions/g, to create quantifiable signatures relative to intrinsic emissions. Applied radiation tagging is determined to be technically feasible, but its operational context and practical implementation requires significant development.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Neutron resonance transmission analysis prototype system for thorium fuel cycle safeguards

Emerging thorium-based reactor designs and fuel cycles present challenges to traditional non-destructive assay techniques used in international safeguards. Specifically, assaying the masses of 233 U and 235 U when they are present together in samples with high gamma ray backgrounds is difficult because of similar passive neutron signatures and relatively weak gamma-ray emissions of 233 U. The Pacific Northwest National Laboratory (PNNL) and the Massachusetts Institute of Technology (MIT) are developing a compact neutron resonance transmission analysis (NRTA) system as one potential solution to these challenges. The NRTA technique provides isotopic information for a sample via neutron time-of-flight (TOF) measurements that exploit a sample’s epithermal neutron resonance cross-sections. A recently developed portable NRTA system uses a commercially available, pulsed deuterium-tritium neutron generator with a ~2 m flight path and a GS20 lithium glass scintillator detector. Finally, this paper describes the prototype NRTA system design, a refined radiation transport model of the system, preliminary measurements with thorium and uranium sources, and demonstration of a quantitative isotopic estimation algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Mid-Project Report)

This project is developing new Non-Destructive Assay (NDA) safeguards techniques for emergent thorium fuel cycles based on Neutron Resonance Transmission Analysis (NRTA), which can assay 233 U and 235 U when they are present together in a sample with potentially high gamma-ray backgrounds from fission products and 232 U. Existing passive techniques face large challenges for this task so new active interrogation methods are needed. This effort is also exploring how gamma-ray signatures can complement NRTA for enhanced assayed performance. This project leverages an NRTA system being developed at PNNL in collaboration with MIT, which uses a commercially available deuterium-tritium neutron generator at short standoff (~2 m). We aim to assess the feasibility and performance of these new NDA techniques for the range of relevant samples in thorium fuel cycles. Key advancements described in this mid-project report include NRTA system design for thorium safeguards measurements, characterization of 233 U oxide powder at PNNL, a survey of detector technologies suitable for NRTA in high gamma background environments, successful preliminary demonstration of a quantitative isotopic estimation algorithm, and first NRTA measurements of a thorium sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Viability of an Unattended Verification Station for UF6 Cylinders: Phase I Findings

In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by the front end of the nuclear fuel cycle. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Station (UCVS), which could provide automated, independent verification of the declared relative enrichment, 235U mass, total uranium mass, and identification for all declared uranium hexafluoride (UF6) cylinders in a facility (e.g., uranium enrichment plants and fuel fabrication plants). Under the auspices of the United States and European Commission Support Programs to the IAEA, a project was undertaken to assess the technical and practical viability of the UCVS concept. Phase I of the UCVS viability study was centered on a long-term field trial of a prototype UCVS system at the Westinghouse Fuel Fabrication Facility in South Carolina, USA. A key outcome of the study was a quantitative performance evaluation of two nondestructive assay (NDA) methods being considered for inclusion in a UCVS: Hybrid Enrichment Verification Array (HEVA), and Passive Neutron Enrichment Meter (PNEM). This paper will provide context for the UCVS and potential implementation concepts, a description of the UCVS prototype design, and an overview of the long-term field trial at a fuel fabrication facility. Selected field-trial results and interpretation are presented, including the performance of PNEM and HEVA for the verification of declared enrichment and 235U mass in over 200 “typical” Type 30B cylinders. Example results from a modeling study provide a preliminary assessment of sensitivity to material-substitution scenarios, for the as-fielded NDA methods.

Smith, Leon E.↗

Analysis of an Indirect Neutron Signature for Enhanced UF6 Cylinder Verification

The International Atomic Energy Agency (IAEA) currently uses handheld gamma-ray spectrometers combined with ultrasonic wall-thickness gauges to verify the declared enrichment of uranium hexafluoride (UF6) cylinders. The current method provides relatively low accuracy for the assay of 235U enrichment, especially for natural and depleted UF6. Furthermore, the current method provides no capability to assay the absolute mass of 235U in the cylinder due to the localized instrument geometry and limited penetration of the 186-keV gamma-ray signature from 235U. Also, the current verification process is a time-consuming component of on-site inspections at uranium enrichment plants. Toward the goal of a more-capable cylinder assay method, the Pacific Northwest National Laboratory has developed the hybrid enrichment verification array (HEVA). HEVA measures both the traditional 186-keV direct signature and a non-traditional, high-energy neutron-induced signature (HEVANT). HEVANT enables full-volume assay of UF6 cylinders by exploiting the relatively larger mean free paths of the neutrons emitted from the UF6. In this work, Monte Carlo modeling is used as the basis for characterizing HEVANT in terms of the individual contributions to HEVANT from nuclides and hardware components. Monte Carlo modeling is also used to quantify the intrinsic efficiency of HEVA for neutron detection in a cylinder-assay geometry. Modeling predictions are validated against neutron-induced gamma-ray spectra from laboratory measurements and a relatively large population of Type 30B cylinders spanning a range of enrichments. Implications of the analysis and findings on the viability of HEVA for cylinder verification are discussed, such as the resistance of the HEVANT signature to manipulation by the nearby placement of neutron-conversion materials.

Monte Carlo↗

Viability Study for an Unattended UF 6 Cylinder Verification Station: Phase I Final Report

In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by the front end of the nuclear fuel cycle. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Station (UCVS) that could provide automated, independent verification of the declared relative enrichment, 235 U mass, total uranium mass and identification for all declared UF 6 cylinders in a facility (e.g., uranium enrichment plants and fuel fabrication plants). Under the auspices of the United States and European Commission Support Programs to the IAEA, a project was undertaken to assess the technical and practical viability of the UCVS concept. The US Support Program team consisted of Pacific Northwest National Laboratory (PNNL, lead), Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL) and Savanah River National Laboratory (SRNL). At the core of the viability study is a long-term field trial of a prototype UCVS system at a Westinghouse fuel fabrication facility. A key outcome of the study is a quantitative performance evaluation of two nondestructive assay (NDA) methods being considered for inclusion in a UCVS: Hybrid Enrichment Verification Array (HEVA), and Passive Neutron Enrichment Meter (PNEM). This report provides context for the UCVS concept and the field trial: potential UCVS implementation concepts at an enrichment facility; an overview of UCVS prototype design; field trial objectives and activities. Field trial results and interpretation are presented, with a focus on the performance of PNEM and HEVA for the assay of over 200 “typical” Type 30B cylinders, and the viability of an “NDA Fingerprint” concept as a high-fidelity means to periodically verify that the contents of a given cylinder are consistent with previous scans. A modeling study, combined with field-measured instrument uncertainties, provides an assessment of the partial-defect sensitivity of HEVA and PNEM for both one-time assay and (repeated) NDA Fingerprint verification scenarios. The findings presented in this report represent a significant step forward in the community’s understanding of the strengths and limitations of the PNEM and HEVA NDA methods, and the viability of the UCVS concept in front-end fuel cycle facilities. This experience will inform Phase II of the UCVS viability study, should the IAEA pursue it.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hybrid Enrichment Verification Array: Module Characterization Studies

The work presented in this report is focused on the characterization and refinement of the Hybrid Enrichment Verification Array (HEVA) approach, which combines the traditional 186-keV 235 U signature with high-energy prompt gamma rays from neutron capture in the detector and surrounding collimator material, to determine the relative enrichment and 235 U mass of the cylinder. The design of the HEVA modules (hardware and software) deployed in the current field trial builds on over seven years of study and evolution by PNNL, and consists of a ø3''×3'' NaI(Tl) scintillator coupled to an Osprey digital multi-channel analyzer tube base from Canberra. The core of the HEVA methodology, the high-energy prompt gamma-ray signature, serves as an indirect method for the measurement of total neutron emission from the cylinder. A method for measuring the intrinsic efficiency of this “non-traditional” neutron signature and the results from a benchmark experiment are presented. Also discussed are potential perturbing effects on the non-traditional signature, including short-lived activation of materials in the HEVA module. Modeling and empirical results are presented to demonstrate that such effects are expected to be negligible for the envisioned implementation scenario. In comparison to previous versions, the new design boosts the high-energy prompt gamma-ray signature, provides more flexible and effective collimation, and improves count-rate management via commercially available pulse-processing electronics with a special modification prompted by PNNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo

Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide an estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead Slowing Down Spectrometry Analysis of Data from Measurements on Nuclear Fuel

Improved non-destructive assay of isotopic masses in used nuclear fuel would be valuable for nuclear safeguards operations associated with the transport, storage and reprocessing of used nuclear fuel. Our collaboration is examining the feasibility of using lead slowing down spectrometry techniques to assay the isotopic fissile masses in used nuclear fuel assemblies. We present the application of our analysis algorithms on measurements conducted with a lead spectrometer. The measurements involved a single fresh fuel pin and discrete 239Pu and 235U samples. We are able to describe the isotopic fissile masses with root mean square errors over seven different configurations to 6.35% for 239Pu and 2.7% for 235U over seven different configurations. Funding Source(s):

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulations of Material-Dependent Detector Responses for Airborne Gamma-Ray Spectroscopy

The aim of this work is to create a library of predicted detector responses used for real-time background estimation during airborne gamma-ray spectroscopy. The simulated spectra are a function of naturally occurring radioactive potassium, uranium, and thorium (KUT) and radioactive daughter products which are present in terrestrial-based materials. Self-attenuation within these materials varies, such that the gamma spectra emitted from the surfaces can differ, despite all having KUT origins. This study also compared various simulated detector responses among materials to determine if some could be accurately scaled from another across reasonable helicopter altitudes and orientations, relative to the ground. Results show that materials with comparable sample thicknesses can be scaled consistently across altitude. This work allows for efficient background estimation via aggregation of simulated detector responses in real time.

radioactive potassium, uranium, and thorium, KUT, ↗

Estimating radiological background using imaging spectroscopy

Optical imaging spectroscopy is investigated as a method to estimate radiological background by spectral identification of soils, sediments, rocks, minerals and building materials derived from natural materials and assigning tabulated radiological emission values to these materials. Radiological airborne surveys are undertaken by local, state and federal agencies to identify the presence of radiological materials out of regulatory compliance. Detection performance in such surveys is determined by (among other factors) the uncertainty in the radiation background; increased knowledge of the expected radiation background will improve the ability to detect low-activity radiological materials. Radiological background due to naturally occurring radiological materials (NORM) can be estimated by reference to previous survey results, use of global 40K, 238U, and 232Th (KUT) values, reference to existing USGS radiation background maps, or by a moving average of the data as it is acquired. Each of these methods has its drawbacks: previous survey results may not include recent changes, the global average provides only a zero-order estimate, the USGS background radiation map resolutions are coarse and are accurate only to 1 km – 25 km sampling intervals depending on locale, and a moving average may essentially low pass filter the data to obscure small changes in radiation counts. Imaging spectroscopy from airborne or spaceborne platforms can offer higher resolution identification of materials and background, as well as provide imaging context information. AVIRIS hyperspectral image data is analyzed using commercial exploitation software to determine the usefulness of imaging spectroscopy to identify qualitative radiological background emissions when compared to airborne radiological survey data.

background radiation estimation↗

Hybrid Enrichment Verification Array: Investigations of the High-Energy Gamma-Ray Signature Origin and Use for Partial Defect Detection

The International Atomic Energy Agency (IAEA) is exploring the use of an Unattended Cylinder Verification Station (UCVS) to provide independent verification of the declared relative 235U enrichment, 235U mass and total uranium mass of the declared UF6 cylinders moving through modern centrifuge enrichment plants. The Hybrid Enrichment Verification Array (HEVA) method is a candidate nondestructive assay method for inclusion in a UCVS. Modeling and measured data from several field campaigns have demonstrated the potential of the HEVA method to assay relative cylinder enrichment with a precision comparable to or substantially better than today’s high-resolution handheld devices. The HEVA instrument is comprised of an array of sodium iodide gamma-ray detectors that measure two primary spectral components. One of these components is the traditional, direct, weakly-penetrating 235U gamma-ray signature, which contains the 186 keV photopeak. The other spectral component is a non-traditional, high-energy (above ~3 MeV) gamma-ray signature, which is generated indirectly from neutrons emitted from within the UF6 cylinder. These neutrons are more penetrating and create high-energy gamma rays through neutron capture reactions in the steel collimators surrounding the detectors and within the detector crystals. This paper will present results from Monte Carlo simulations and analyses of the HEVA method with a focus on the origins of this high-energy signature, the optimization of instrument design to enhance the signature, and the ability of this non-traditional signature to reveal partial defect scenarios wherein material is missing or substituted in the interior of the cylinder.

Enrichment↗

Measurement and Analysis of Gamma-Rays Emitted From Spent Nuclear Fuel Above 3 MeV

The gamma-ray spectrum of spent nuclear fuel in the 3- to 6-MeV energy range is important for active interrogation since emitted gamma rays emitted from nuclear decay are not expected to interfere with measurements in this energy region. There is, unfortunately, a dearth of empirical measurements from spent nuclear fuel in this region. This work is an initial attempt to partially ll this gap by presenting an analysis of gamma-ray spectra collected from a set of spent nuclear fuel sources using a high-purity germanium detector array. This multi-crystal array possesses a large collection volume, providing high energy resolution up to 16 MeV. The results of these measurements establish the continuum count-rate in the energy region between 3- and 6-MeV. Also assessed is the potential for peaks from passive emissions to interfere with peak measurements resulting from active interrogation delayed emissions. As one of the first documented empirical measurements of passive emissions from spent fuel for energies above 3 MeV, this work provides a foundation for active interrogation model validation and detector development.

delayed gamma rays↗

Lead Slowing Down Spectrometer FY2013 Annual Report

Executive Summary The Lead Slowing Down Spectrometry (LSDS) project, funded by the Materials Protection And Control Technology campaign, has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner.

Warren, Glen A.↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗

Update on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) of next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to address the feasibility of Lead Slowing Down Spectroscopy (LSDS) as an active, nondestructive assay method. LSDS has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than today’s confirmatory assay methods, for which typical uncertainties are approximately 10%. LSDS techniques are sensitive to the fission resonances in the energy range of ~0.1-1000 eV, enabling their use to determine the mass content of the fissile isotopes in used fuel. This paper will present an update with regard to applying LSDS for used fuel assay and the development of algorithms to extract fissile isotopic masses from the used fuel.

Lead Slowing Down Spectroscopy, Used Fuel, Spent F↗

Assaying Used Nuclear Fuel Assemblies Using Lead Slowing-Down Spectroscopy and Singular Value Decomposition

This study investigates the use of a Lead Slowing-Down Spectrometer (LSDS) for the direct and independent measurement of fissile isotopes in light-water nuclear reactor fuel assemblies. The current study applies MCNPX, a Monte Carlo radiation transport code, to simulate the measurement of the assay of the used nuclear fuel assemblies in the LSDS. An empirical model has been developed based on the calibration of the LSDS to responses generated from the simulated assay of six well-characterized fuel assemblies. The effects of self-shielding are taken into account by using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the self-shielding functions from the assay of assemblies in the calibration set. The performance of the empirical algorithm was tested on version 1 of the Next-Generation Safeguards Initiative (NGSI) used fuel library consisting of 64 assemblies, as well as a set of 27 diversion assemblies, both of which were developed by Los Alamos National Laboratory. The potential for direct and independent assay of the sum of the masses of Pu-239 and Pu-241 to within 2%, on average, has been demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗