Engineering Papers⌕ Search

Engineering topics

Kulevoy, T V

Publications and source records attributed to Kulevoy, T V.

Numerical simulation of gridded electrostatic lens

Gridded electrostatic lenses are frequently used in extraction systems and low energy ion beam transport line. Typically, for numerical simulation the grid is treated as a metal plate transparent for beam particles. The influence of real grid geometry on the beam dynamics in the gridded lens has been investigated by KOBRA-3d code. Beam emittance growth for different lens parameters has been investigated. Approximating expressions for obtained results are presented. The grid geometry providing minimal beam distortions is proposed.

43 PARTICLE ACCELERATORS↗

Molecular phosphorus ion source for semiconductor technology

This paper presents results on the generation of molecular phosphorus ion beams in a hot filament ion source. Solid red phosphorous is evaporated mainly as tetra-atomic molecules up to a temperature of 800 deg. C. Thus, one of the main conditions for producing maximum P{sub 4}{sup +} fraction in the beam is to keep the temperature of the phosphorous oven, the steam line and the discharge chamber walls no greater than 800 deg. C. The prior version of our ion source was equipped with a discharge chamber cooling system. The modified source ensured a P{sub 4}{sup +} ion beam current greater than 30% of the total beam current.

43 PARTICLE ACCELERATORS↗

Rhenium ion beam for implantation into semiconductors

At the ion source test bench in Institute for Theoretical and Experimental Physics the program of ion source development for semiconductor industry is in progress. In framework of the program the Metal Vapor Vacuum Arc ion source for germanium and rhenium ion beam generation was developed and investigated. It was shown that at special conditions of ion beam implantation it is possible to fabricate not only homogenous layers of rhenium silicides solid solutions but also clusters of this compound with properties of quantum dots. At the present moment the compound is very interesting for semiconductor industry, especially for nanoelectronics and nanophotonics, but there is no very developed technology for production of nanostructures (for example quantum sized structures) with required parameters. The results of materials synthesis and exploration are presented.

36 MATERIALS SCIENCE↗

Ion Source of Pure Single Charged Boron Based on Planar Magnetron Discharge in Self-Sputtering Mode

A planar magnetron sputtering device with thermally isolated sintered boron target has been designed and demonstrated. The magnetron is intended to use for generation of boron ion beams, as well as in plasma immersion implantation. For a boron target, high target temperature is required because boron has low electrical conductivity at room temperature, which increases with temperature. The target is well insulated thermally and can be heated by an initial low-current, high-voltage DC discharge mode. A discharge power of 16 W was adequate to reach the required surface temperature, after that a transition of the discharge to a high-current, low-voltage mode is observed. Applying high current pulses over the DC heating discharge results in a self-sputtering operational mode of the magnetron discharge. Ion beam was extracted from the discharge plasma. Beam analysis was performed with a time-of-flight system. All the boron ions are single charged. The maximum boron ion fraction in the beam is greater than 99%, and the mean boron ion fraction, time-integrated over the whole pulse length, is about 95%. This kind of boron ion source could be competitive to conventional boron ion sources that utilize compounds such as BF{sub 3}, and could be useful for semiconductor industry application.

36 MATERIALS SCIENCE↗

Molecular Ion Beam Transportation for Low Energy Ion Implantation

A joint research and development of steady state intense boron ion sources for 100's of electron-volt ion implanters has been in progress for the past five years. Current density limitation associated with extracting and transporting low energy ion beams result in lower beam currents that in turn adversely affects the process throughput. The transport channel with electrostatic lenses for decaborane (B{sub 10}H{sub 14}) and carborane (C{sub 2}B{sub 10}H{sub 12}) ion beams transportation was developed and investigated. The significant increase of ion beam intensity at the beam transport channel output is demonstrated. The transport channel simulation, construction and experimental results of ion beam transportation are presented.

43 PARTICLE ACCELERATORS↗

Sources and transport systems for low energy extreme of ion implantation

For the past seven years a joint research and development effort focusing on the design of steady state, intense ion sources has been in progress with the ultimate goal being to meet the two, energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. However, since the last Fortier is low energy ion implantation, focus of the endeavor has shifted to low energy ion implantation. For boron cluster source development, we started with molecular ions of decaborane (B{sub 10}H{sub 14}), octadecaborane (B{sub 18}H{sub 22}), and presently our focus is on carborane (C{sub 2}B{sub 10}H{sub 12}) ions developing methods for mitigating graphite deposition. Simultaneously, we are developing a pure boron ion source (without a working gas) that can form the basis for a novel, more efficient, plasma immersion source. Our Calutron-Berna ion source was converted into a universal source capable of switching between generating molecular phosphorous P{sub 4}{sup +}, high charge state ions, as well as other types of ions. Additionally, we have developed transport systems capable of transporting a very large variety of ion species, and simulations of a novel gasless/plasmaless ion beam deceleration method were also performed.

36 MATERIALS SCIENCE↗

Boron ion source based on planar magnetron discharge in self-sputtering mode

An ion source based on a planar magnetron sputtering device with thermally isolated target has been designed and demonstrated. For a boron sputtering target, high target temperature is required because boron has low electrical conductivity at room temperature, increasing with temperature. The target is well-insulated thermally and can be heated by an initial low-current, high-voltage discharge mode. A discharge power of 16 W was adequate to attain the required surface temperature (400 C), followed by transition of the discharge to a high-current, low-voltage mode for which the magnetron enters a self-sputtering operational mode. Beam analysis was performed with a time-of-flight system; the maximum boron ion fraction in the beam is greater than 99%, and the mean boron ion fraction, time-integrated over the whole pulse length, is about 95%. We have plans to make the ion source steady state and test with a bending magnet. This kind of boron ion source could be competitive to conventional boron ion sources that utilize compounds such as BF3, and could be useful for semiconductor industry application.

43 PARTICLE ACCELERATORS↗

Sources for Low Energy Extreme of Ion Implantation

A joint research and development effort focusing on the design of steady state, intense ion sources has been in progress for the past four and a half years. The ultimate goal is to meet the two, energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has resulted in record steady state output currents of higher charge state Antimony and Phosphorous ions: P{sup 2+}(8.6 pmA), P{sup 3+}(1.9 pmA), and P{sup 4+}(0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. During the past year the effort was channeled towards low energy implantation, for which the effort involved molecular ions and a novel plasmaless/gasless deceleration method. To date, 3 emA of positive Decaborane ions were extracted at 14 keV and a smaller current of negative Decaborane ions were also extracted. Additionally, a Boron fraction of over 70% was extracted from a Bernas-Calutron ion source.

43 PARTICLE ACCELERATORS↗

Ion sources for energy extremes of ion implantation (invited)

For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques that meet the two energy extreme range needs of meV and hundreads of eV ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of antimony and phosphorus ions: P{sup 2+} [8.6 pmA (particle milliampere)], P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+}Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. For low energy ion implantation, our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA (electrical milliampere) of positive decaborane ions was extracted at 10 keV and smaller currents of negative decaborane ions were also extracted. Additionally, boron current fraction of over 70% was extracted from a Bernas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental comparison of time-of-flight mass analysis with magnetic mass analysis

A series of experiments was carried out in which both a magnetic analyzer (mass separator) and a time-of-flight (TOF) spectrometer were used for ion charge/mass spectral analysis of the ion beam formed by a dc Bernas ion source made for semiconductor implantation. The TOF analyzer was a detachable device that provides rapid analysis of charge-to-mass composition of moderate energy ion beams. The magnetic analyzer was a massive device using a 90 deg.-sector bending magnet with radius of the central orbit of 35 cm. Comparison of these two methods for measuring ion beam composition shows good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of ITEP decaborane ion source program

The joint research and development program is continued to develop steady-state ion source of decaborane beam for ion implantation industry. Both Freeman and Bernas ion sources for decaborane ion beam generation were investigated. Decaborane negative ion beam as well as positive ion beam were generated and delivered to the output of mass separator. Experimental results obtained in ITEP are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Front-end simulation of injector for terawatt accumulator

A terawatt accumulator (TWAC) accelerator/storage ring complex with the laser ion source is in progress at ITEP. The new injector I4 based on the radio frequency quadrupole (RFQ) and interdigital H-mode (IH) linear accelerator is under construction. The front end of the new TWAC injector consists of a laser ion source, an extraction system, and a low energy beam transport (LEBT). The KOBRA3-INP was used for the simulation and optimization of the ion source extraction system. The optimization parameter is the maximum brightness of the beam generated by the laser ion source. Also the KOBRA3-INP code was used for LEBT investigation. The LEBT based on electrostatic grid lenses is chosen for injector I4. The results of the extraction system and LEBT investigations for ion beam matching with RFQ are presented.

43 PARTICLE ACCELERATORS↗

Bernas ion source discharge simulation

As the technology and applications continue to grow up, the development of plasma and ion sources with clearly specified characteristic is required. Therefore comprehensive numerical studies at the project stage are the key point for ion implantation source manufacturing (especially for low energy implantation). Recently the most commonly encountered numerical approach is the Monte Carlo particle-in-cell (MCPIC) method also known as particle-in-cell method with Monte Carlo collisions. In ITEP the 2D3V numerical code PICSIS-2D realizing MCPIC method was developed in the framework of the joint research program. We present first results of the simulation for several materials interested in semiconductors. These results are compared with experimental data obtained at the ITEP ion source test bench.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗