Engineering Papers⌕ Search

Engineering topics

Kulecz, Walter B.

Publications and source records attributed to Kulecz, Walter B..

Device and Method for Digital-To-Analog Transformations and Reconstructions of Multi-Channel Electrocardiograms

The present invention includes a method and apparatus for digital to analog conversion and reconstruction of multichannel electrocardiograms. The method may include receiving digital information representative of a plurality of independent signals, producing a plurality of analog outputs from said digital information wherein a first analog output is designated as a common reference, and imposing a predetermined voltage on a second analog output with respect to said common reference, which provides for a substantial recreation of the original independent signals. The apparatus may comprise a processor operable for receiving digital information representative of independent lead signals from a first ECG machine and digital to analog circuitry for substantially reproducing the original lead signals for analysis on a second ECG machine for convenient and efficient second opinions of cardiac data.

Schlegel, Todd T.↗

Visual Performance Challenges to Low-Frequency Perturbations After Long-Duration Space Flight, and Countermeasure Development

Astronauts experience sensorimotor disturbances after long-duration space flight. After a water landing, crewmembers may need to egress the vehicle within a few minutes for safety and operational reasons in various sea state conditions. Exposure to even low-frequency motions induced by sea conditions surrounding a vessel can cause significant motor control problems affecting critical functions. The first objective of this study was to document human visual performance during simulated wave motion below 2.0 Hz. We examined the changes in accuracy and reaction time when subjects performed a visual target acquisition task in which the location of the target was offset vertically during horizontal rotation at an oscillating frequency of 0.8 Hz. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements occurring when vertical targets were acquired at perturbing frequencies of 0.8 Hz in the horizontal plane. A second objective was to develop a countermeasure, base d on stochastic resonance (SR), to enhance sensorimotor capabilities with the aim of facilitating rapid adaptation to gravitational transitions after long-duration space flight. SR is a mechanism by which noise can enhance the response of neural systems to relevant sensory signals. Recent studies have shown that applying imperceptible stochastic electrical stimulation to the vestibular system (SVS) significantly improved balance and oculomotor responses. This study examined the effectiveness of SVS on improving balance performance. Subjects performed a standard balance task while bipolar SVS was applied to the vestibular system using constant current stimulation through electrodes placed over the mastoid process. The main finding of this study was that balance performance with the application of SR showed significant improvement in the range of 10%-25%. Ultimately an SR-based countermeasure might be fielded either as preflight training to enhance adaptability, or as a miniature patch-type stimulator worn post flight.

Mulavara, Ajitkumar↗

Effect of Passive Horizontal Rotations and Vertical Oscillations on Dynamic Visual Acuity

Astronauts experience sensorimotor disturbances after long duration space flight. These crewmembers may need to egress the vehicle within a few minutes for safety and operational reasons in various sea state conditions following a water landing. Exposure to even low frequency motions induced by sea conditions surrounding a vessel can cause significant fine and gross motor control problems affecting critical functions. The objective of this study was to document human motor and visual performance during simulated wave motion in the 0.1 to 2.0 Hz range. We examined in 12 healthy subjects the changes in accuracy when performing a seated visual target acquisition task in which the location of target was offset vertically during horizontal full body rotation at an oscillating frequency of 0.8 Hz (peak velocity of 160 deg/s). The main finding was that the accuracy of performance degraded in 7 of 12 subjects when acquiring vertical targets at perturbing frequencies of 0.8 Hz in the horizontal plane by one step size. We also examined in a separate study on 12 healthy subjects seated dynamic visual acuity (DVA) task performance during vertical full body oscillations at perturbing frequencies of 2 Hz (peak to peak motion of 5 cm). The main finding was that DVA was significantly reduced when acquiring targets at perturbing oscillations at frequencies of 2 Hz in the vertical plane by approximately 1 chart line. Thus low frequencies of perturbations in the horizontal and vertical planes can cause decrement in visual performance.

Mulavara, Ajitkumar↗

Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

Software↗

System Collects And Displays Demultiplexed Data

Electronic system collects, manipulates, and displays in real time results of manipulation of streams of data transmitted from remote scientific instrumentation. Interface circuit shifts data-and-clock signal from differential logic levels of multiplexer to single-ended logic levels of computer. System accommodates nonstandard data-transmission protocol. Software useful in applications where Macintosh computers used in real-time display and recording of data.

Reschke, Millard F.↗

Role of otolith endorgans in the genesis of vestibular-visual conflict sickness (pitch) in the squirrel monkey (First report)

The effects of ablation of the macula utriculi and macula sacculi on vestibular-visual conflict emesis in squirrel monkeys are investigated. An optokinetic drum and a turntable were used for the direction conflict experiment. A significant difference between the preoperative condition and postunilateral and postbilateral utriculo-sacculectomy conditions is observed. It is detected that after unilateral sacculectomy the conflict sickness decreases and no emesis occurs; however, 4.5 months after sacculectomy, the animals regain their conflict sickness. The data reveal that macular afferents are important in the genesis of sensory conflict emesis and two submodalities may be needed to cause conflict sickness onset.

Igarashi, Makoto↗

Vestibular-visual conflict training

Squirrel monkeys susceptible to vestibular-visual conflict (similar to that produced in space motion) were successfully trained to lesser sensitivity by repeated exposures to various randomly mixed patterns of vestibular-visual conflict in sagittal plane. As long as the training effect was retained, trained animals exhibited low sickness scores and no emesis. It is suggested that the adaptation maneuvers described in this study can be effective as a training routine for crew members immediately prior to their space flight missions.

Igarashi, Makoto↗

Vestibular-visual conflict in pitch and yaw planes in the squirrel monkey

Direction conflicting vestibular and visual (optokinetic) stimuli either in the pitch or yaw plane were given to squirrel monkey subjects. The conflict sickness symptom score in the pitch plane was significantly higher than that in the yaw plane for the initial exposure session (p less than 0.01). A significant score difference was also encountered when the exposure sessions were repeated (p less than 0.05).

Igarashi, Makoto↗