Engineering Papers⌕ Search

Engineering topics

Krygier, A.

Publications and source records attributed to Krygier, A..

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ~3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ~1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Optimized continuum x-ray emission from laser-generated plasma

We study continuum x-ray emission from hot plasma at the National Ignition Facility (NIF). We find that the x-ray yield in the multi-keV photon energy range is larger in Ti than in Ag or Au. This apparent paradox is due to Ti K-shell vacancies generated by the extraordinary energy density achieved by the NIF lasers. This is supported by direct observations of large continuum enhancement above the Ti K-series limit due to both free–bound (recombination) emission and strong Ly α (H-like) emission. Detailed calculations agree well with our measurements and support our conclusions. <!--/abstract content--><!--fulltext content--> X-ray emission from matter pervades the universe and plays an important role in the high-energy density (HED) regime (~10 5 J/cm 3 ). For example, the emission and absorption of x-rays controls the thermal state and evolution of stellar interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗