Engineering PapersSearch

Engineering topics

Kruger, R.

Publications and source records attributed to Kruger, R..

At least 19 records

OSS-1/contamination monitor

A 20-cm high, 18-cm wide, and 30-cm long (8x7x12 inch) box weighing about 7 kg (15 lbs) and consuming about 7 watts of power was carried on the OSS-1 pallet to monitor the mass build-up or accretion of condensible, volatile materials on surfaces in the shuttle bay during all phases of ascent, on-orbit, and descent. Passively thermally controlled, the box holds two witness samples and four actively temperature controlled quartz crystal microbalances (TQCM) whose temperature can vary from -60 C to +80 C. Graphs show the accretion indicated by the TQCM during the launch and early orbital phase. Conditions during tail to the Sun, nose to the Sun, and bay to the Sun attitudes of the shuttle during STS-3 are reflected in temperatures indicated by the OSS-1 thermistor. These temperatures influence outgassing rates of various materials as well as measurements made by the contamination monitor package. The parameters that bear on TQCM measurements data are shown in graphs and discussed.

Kruger, R.

The NASA/GSFC hydrogen maser program: A review of recent data

Data is presented on the phase and frequency stability, over time periods extending to one week, of the new NR field operable hydrogen masers developed by the Applied Physics Laboratory (APL) and the older NX and NP field operable hydrogen masers developed by Goddard Space Flight Center and maintained and upgraded by Bendix Field Engineering Corporation (BFEC). Data is presented on the NR masers in the laboratory showing frequency stabilities well into the 10 to the -15th power range and phase stabilities well into the 100 ps range for periods of up to one day. Data is presented on upgraded NP masers in the laboratory showing that the frequency stability has been improved substantially to virtually the NR level. VLBI data is presented on the phase difference between NX-2 at Owens Valley, California and NR-2 at Fort Davis, Texas for a one week period showing, after removal of a constant frequency drift, a 350 ps RMS phase stability.

Chiu, M.

Results from a 'small box' realtime molecular contamination monitor on STS-3

On the basis of early estimates of the Shuttle induced environment, Scialdone (1979) concluded that in the vicinity of the cargo, the cargo would have the largest influence on the environment. As a contamination control device, realtime monitors can indicate safe operational periods for sensitive attached payloads. It was, therefore, decided to develop the OSS-1/Contamination Monitor Package (CMP) experiment which was seen as a forerunner of an operational monitor. A description of the CMP is provided, taking into account four actively temperature controlled quartz crystal microbalances (TQCM). The TQCM temperatures could be varied from -60 C to +80 C. The sensor consisted of a matched pair of quartz crystals. The crystals were designated as a sensor and reference crystal. Results obtained during the STS-3 mission are discussed. These results show the feasibility and advantages of a small real-time contamination monitor.

Triolo, J.

An approach to thermal-vacuum test optimization

An analytical model is presented that simulates failure rate characteristics of spacecraft equipment progressing through component and system level thermal-vacuum test programs and on into orbit. Costs for the test programs are part of the model as well as costs attributable to the mission. A lost value function combines the performance of the equipment with these costs and allows comparisons to be made among various test combinations and the resulting predicted mission performance. A minimum overall cost program is obtained by selecting that test program that yields the lowest lost value figure.

Kruger, R.

Estimation procedures to measure and monitor failure rates of components during thermal-vacuum testing

Estimation procedures are described for measuring component failure rates, for comparing the failure rates of two different groups of components, and for formulating confidence intervals for testing hypotheses (based on failure rates) that the two groups perform similarly or differently. Appendix A contains an example of an analysis in which these methods are applied to investigate the characteristics of two groups of spacecraft components. The estimation procedures are adaptable to system level testing and to monitoring failure characteristics in orbit.

Williams, R. E.

Experiments on the effect of ultraviolet on contamination in vacuum systems

A series of experiments designed to investigate the effect of irradiating a portion of a vacuum system with ultraviolet (UV) light are discussed. Data obtained with the quartz crystal microbalance show that, under ultraviolet irradiation, clean and contaminated mean different things than in situations that do not involve irradiation. The history of the chamber appears to be of paramount importance, not the pumping mechanism. UV irradiation check for contamination is recommended in critical experiments.

Kruger, R.

A thermal vacuum test optimization procedure

An analytical model was developed that can be used to establish certain parameters of a thermal vacuum environmental test program based on an optimization of program costs. This model is in the form of a computer program that interacts with a user insofar as the input of certain parameters. The program provides the user a list of pertinent information regarding an optimized test program and graphs of some of the parameters. The model is a first attempt in this area and includes numerous simplifications. The model appears useful as a general guide and provides a way for extrapolating past performance to future missions.

Kruger, R.

Quartz-crystal-oscillator hygrometer

Measuring device, which eliminates complex and expensive optical components by electronically sensing dewpoint of water vapor in gas, employs piezoelectric crystal oscillator, supportive circuitry, temperature regulators, and readout.

Kruger, R.

Estimation of outgassing from an expended apogee motor and its effects on spacecraft surfaces

An experimental and theoretical investigation was carried out to evaluate the degradation of the solar cells and other sensitive surfaces of a spacecraft, resulting from the molecular outgassing of an expended solid propellant apogee motor. The motor, following its burnout, is retained by the spacecraft and is a source of gases and particulates which will be released mainly by the unburned propellant-to-casing insulation. The deployment of the solar array within a few minutes after the motor burn results in the interception and reflection to the surfaces of the spacecraft of the molecular outgassing and particulates. Various methods, based on some experimental data, were used to analytically assess the magnitude of the outgassing from the engine.

Scialdone, J. J.

Optimization of spacecraft high temperature outgassing duration

Spacecraft systems are baked-out under vacuum to remove occluded and adsorbed gases, solvents, water, plasticizer, and other materials acquired during their manufacture. Two bakeouts of solar panels were carried out. Quartz crystal microbalances installed in the vacuum chamber during the tests and held at 273 K (0 C) provided an ongoing measure of the panels' outgassing. From these data, the panels' material weight losses versus time were obtained. A comparison of the total weight loss expected during a relatively long bakeout with that accomplished during a reasonable period of time was used as a criteria for an acceptable duration of the bakeout in order to optimize cost effectiveness.

Scialdone, J. J.

Experiments in determining the outgassing of spacecraft in the vacuum environment

As spacecraft become more sophisticated, their contamination becomes of increasing concern. The use of real-time monitors, such as the quartz crystal microbalance, and post-test methods such as the chemical analysis of residuals, has been combined with a number of analytical techniques in contamination-related investigations at the Goddard Space Flight Center. These include the establishment of the cause of an orbital failure, the determination of component outgassing rates, and the monitoring of contaminants in vacuum chambers and in orbit. Improved capabilities appear possible with measurement methods such as attenuated total reflectance and better analytical modeling of the contaminant flux environment.

Kruger, R.

A Comparison of Quartz Crystal Microbalance Measurements with Mass Spectrometer Determinations

An experimental program was undertaken in which mass accretion rates, as determined by a liquid nitrogen cooled quartz crystal microbalance, were compared with the mass flux rates, as determined by both a cycloidal type and a quadrupole type residual gas analyzer for five simple materials. The data indicate a high degree of correlation between these instruments insofar as the shape of the curves. There are large variations however among the absolute values.

Kruger, R.