Engineering PapersSearch

Engineering topics

Krebs, Carolyn

Publications and source records attributed to Krebs, Carolyn.

At least 19 records

Automated Figuring and Polishing of Replication Mandrels for X-Ray Telescopes

In support of the Constellation X mission the Optics Branch at Goddard Space Flight Center is developing technology for precision figuring and polishing of mandrels used to produce replicated mirrors that will be used in X-Ray telescopes. Employing a specially built machine controlled in 2 axes by a computer, we are doing automated polishing/figuring of 15 cm long, 20 cm diameter cylindrical, conical and Wolter mandrels. A battery of tests allow us to fully characterize all important aspects of the mandrels, including surface figure and finish, mid-frequency errors, diameters and cone angle. Parts are currently being produced with surface roughnesses at the .5nm RMS level, and half-power diameter slope error less than 2 arcseconds.

Krebs, Carolyn

Optical Dust Characterization in Manned Mars Analogue Research Stations

Martian dust has been identified as a potentially serious hazard to any manned Mars landing mission. NASA and other organizations realize this risk and continue to support Martian dust research through the Matador project led by researchers at the University of Arizona. The Mars Society can contribute to this work by beginning a regimen of monitoring and measuring dust properties at its Mars analogue research stations. These research facilities offer the unique opportunity to study the transport and distribution of dust particles within a crewed habitat supporting active geologic exploration. Information regarding the amount, location and size of dust particles that may accumulate in a Mars habitat will be required to design a real Mars habitat and habitat equipment. Beginning such an effort does not require a large outlay of equipment and can be accomplished using crewmembers experienced with station operations. Various optical techniques, such as dark-field illumination, coupled with image processing algorithms enable the collection of dust grain relative size and frequency information. Such approaches can be applied in several different zones within the research stations to evaluate the various dust reduction and isolation procedures implemented during a particular crew rotation. As the stations simulation fidelity increases, the applicability of such data to a functional Mars lander will increase. This presentation describes the optical equipment and procedures for measuring dust properties in Mars analogue research stations that can be implemented during the next field season.

Bos, B. J.

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.

LISA Optics Model

The LISA experiment has six telescopes, in three spacecraft, in orbit about the sun. There is a continuous laser link between all of the spacecraft. Because of the large, 5 million kilometer distances, between the spacecraft and the need to perform picometer level interferometry and the fact that the optical system is dynamic precludes the use of standard optical codes in the design and analysis of this optical system. A detailed description of the approach used to model all of the optics, in the spacecraft in orbit, is presented and the ability of this model to analyze requirements is discussed. A dynamic computer simulation will be shown to illustrate the laser link and the effects of this dynamic environment on the interferometry.

Waluschka, Eugene

Comparison of Stress Relief Procedures for Cryogenic Aluminum Mirrors

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter) and an engineering prototype for a potential design for the Next Generation Space Telescope/Multi-Object Spectrograph. IRMOS is a low-to mid-resolution (R = lambda/delta-lambda = 300-3800), near-IR (0.8-2.5 micron) spectrograph which produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arcmin field of view using a commercial MEMS multimirror array device. The instrument operating temperature is 80 K and the design is athermal --- the optical bench and mirrors are machined from aluminum 6061-T651. In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress, which, unless relieved during fabrication, may relieve and distort mirror figure to unacceptable levels at the operating temperature. Other cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of a test program designed to empirically determine the best stress relief procedure for the IRMOS mirrors. Identical test mirrors with spherical and flat optical prescriptions are processed with five different heat treatment formulae from the literature and compared to samples with out any additional processing. After figuring via diamond turning, the mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for several thermal cycles. The heat treatment procedure for the mirrors that yielded the least and most repeatable change in figure error and radius is applied to the IRMOS mirror blanks. We correlate the results of our optical testing with heat treatment and metallographic data.

Ohl, Raymond G.

Design, Fabrication, Optical Testing, and Performance of Diamond Machined Aspheric Mirrors for Ground-Based Near-IR Astronomy

Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.

Ohl, Raymond G.

LISA Telescope Sensitivity Analysis

The Laser Interferometer Space Antenna (LISA) for the detection of Gravitational Waves is a very long baseline interferometer which will measure the changes in the distance of a five million kilometer arm to picometer accuracies. As with any optical system, even one with such very large separations between the transmitting and receiving, telescopes, a sensitivity analysis should be performed to see how, in this case, the far field phase varies when the telescope parameters change as a result of small temperature changes.

Waluschka, Eugene

Antenna-Coupled Superconducting Tunnel Junctions with Single-Electron Transistor Readout for Detection of Sub-mm Radiation

Antenna-coupled superconducting tunnel junction detectors have the potential for photon-counting sensitivity at sub-mm wavelengths. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation using Superconducting Tunnel Junctions with Radio-Frequency Single-Electron Transistors

The science drivers for the SPIRIT/SPECS missions demand sensitive, fast, compact, low-power, large-format detector arrays for high resolution imaging and spectroscopy in the far infrared and submillimeter. Detector arrays with 10,000 pixels and sensitivity less than 10(exp 20)-20 W/Hz(exp 20)0.5 are needed. Antenna-coupled superconducting tunnel junction detectors with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique when forming arrays. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.

A Miniature Palladium-Iron Thermometer for Temperatures Down to 0.05 K

Magnetic thermometers are appealing at temperatures below about 0.1 Kelvin, because the avoid the noise self-heating problems associated with resistive thermometers. In practical, metallic dilute electronic thermometers add the advantages of chemical stability, high thermal conductivity, and easy in heat sinking work we describe a palladium-iron thermometer which was designed to be small and conveniently packaged and optimized for use at temperatures down to 0.05 Kelvin. The device showed Curie-Weiss behavior above about 0.06 Kelvin, and we achieve 41 nK/ square root of z temperature resolution at a temperature of 49 mK. We describe the design and operation of this thermometers and present the test results.

Tuttle, Jim

An Architecture Trade Study for Passive 10-km Soil Moisture Measurements from Low-Earth Orbit

In 1999 NASA HQ, as a result of an internal NASA study on potential Earth Science Enterprise Post-2002 Missions, directed the hydrology community to focus on achieving a 10-km spatial resolution global soil moisture mission. This type of resolution represents a significant technological challenge for an L-band radiometer in sun-synchronous low-earth orbit. An engineering trade study has been completed to determine alternative system configurations that could achieve the science requirements and to identify the most appropriate technology investments and development path for NASA to pursue in order to bring about such a mission. The results of the study are presented here together with a short discussion of future efforts.

Pellerano, Fernando

Low Power Silicon Germanium Electronics for Microwave Radiometers

Space-based radiometric observations of key hydrological parameters (e.g., soil moisture) at the spatial and temporal scales required in the post-2002 era face significant technological challenges. These measurements are based on relatively low frequency thermal microwave emission (at 1.4 GHz for soil moisture and salinity, 10 GHz and up for precipitation, and 19 and 37 GHz for snow). The long wavelengths at these frequencies coupled with the high spatial and radiometric resolutions required by the various global hydrology communities necessitate the use of very large apertures (e.g., greater than 20 m at 1.4 GHz) and highly integrated stable RF electronics on orbit. Radio-interferometric techniques such as Synthetic Thinned Array Radiometry (STAR), using silicon germanium (SiGe) low power radio frequency integrated circuits (RFIC), is one of the most promising technologies to enable very large non-rotating apertures in space. STAR instruments are composed of arrays of small antenna/receiving elements that are arranged so that the collecting area is smaller than an equivalent real aperture system, allowing very high packing densities for launch. A 20 meter aperture at L-band, for example, will require greater than 1000 of these receiving elements. SiGe RFIC's reduce power consumption enough to make an array like this possible in the power-limited environment of space flight. An overview of the state-of-the-art will be given, and current work in the area of SiGe radiometer development for soil moisture remote sensing will be discussed.

Doiron, Terence A.

Overview of Selected Light-Weight Mirror Development Programs at GSFC

This paper discusses selected light-weight mirror development programs at GSFC, including development of light-weight, precision, low scatter imaging mirror for ultraviolet applications, foam core mirrors for visible and IR applications, and light-weight SiC mirrors.

Keski-Kuha, Ritva A.

MODIS Solar Diffuser: Modelled and Actual Performance

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument's solar diffuser is used in its radiometric calibration for the reflective solar bands (VIS, NTR, and SWIR) ranging from 0.41 to 2.1 micron. The sun illuminates the solar diffuser either directly or through a attenuation screen. The attenuation screen consists of a regular array of pin holes. The attenuated illumination pattern on the solar diffuser is not uniform, but consists of a multitude of pin-hole images of the sun. This non-uniform illumination produces small, but noticeable radiometric effects. A description of the computer model used to simulate the effects of the attenuation screen is given and the predictions of the model are compared with actual, on-orbit, calibration measurements.

Waluschka, Eugene

UIT Observations of Early-Type Galaxies and Analysis of the FUSE Spectrum of a Subdwarf B Star

This work covers Ultraviolet Imaging Telescope (UIT) observations of early-type galaxies (155 nm) and Far Ultraviolet Spectroscopic Explorer (FUSE) spectra of a Galactic subdwarf B star (sdB). Early UV space astronomy missions revealed that early-type galaxies harbor a population of stars with effective temperatures greater than that of the main sequence turn-off (about 6,000 K) and UV emission that is very sensitive to characteristics of the stellar population. We present UV (155 nm) surface photometry and UV-B color profiles for 8 E and SO galaxies observed by UIT. Some objects have de Vaucouleurs surface brightness profiles, while others have disk-like profiles, but we find no other evidence for the presence of a disk or young, massive stars. There is a wide range of UV-B color gradients, but there is no correlation with metallicity gradients. SdB stars are the leading candidate UV emitters in old, high metallicity stellar populations (e.g., early-type galaxies). We observed the Galactic sdB star PG0749+658 with FUSE and derived abundances with the aim of constraining models of the heavy element distribution in sdB atmospheres. All of the elements measured are depleted with respect to solar, except for Cr and Mn, which are about solar, and Ni, which is enhanced. This work was supported in part by NASA grants NAG5-700 and NAG5-6403 to the University of Virginia and NAS5-32985 to Johns Hopkins University.

Ohl, Raymond G.

LISA Telescope Sensitivity Analysis

The results of a LISA telescope sensitivity analysis will be presented, The emphasis will be on the outgoing beam of the Dall-Kirkham' telescope and its far field phase patterns. The computed sensitivity analysis will include motions of the secondary with respect to the primary, changes in shape of the primary and secondary, effect of aberrations of the input laser beam and the effect the telescope thin film coatings on polarization. An end-to-end optical model will also be discussed.

Waluschka, Eugene

The HAWC and SAFIRE Adiabatic Demagnetization Refrigerators

The High-Resolution Airborne Wide-band Camera (HAWC) and Submillimeter and Far Infrared Experiment (SAFIRE) are far-infrared experiments which will fly on the Stratospheric Observatory for Infrared Astronomy (SOFIA) aircraft. HAWC's detectors will operate at 0.2 Kelvin, while those of SAFIRE will be at 0.1 Kelvin. Each instrument will include an adiabatic demagnetization refrigerator (ADR) to cool its detector stage from the liquid helium bath temperature (HAWC's at 4.2 Kelvin and SAFIRE's pumped to about 1.3 Kelvin) to its operating temperature. Except for the magnets used to achieve the cooling and a slight difference in the heat switch design, the two ADRs are nearly identical. We describe the ADR design and present the results of performance testing.

Tuttle, Jim

Passive Gas-Gap Heat Switches for Use in Adiabatic Demagnetization Refrigerators

We have designed, built, and tested a gas gap heat switch that works passively, without the need for a separate, thermally activated getter. This switch uses He-3 condensed as a thin film on alternating plates of copper. The switch is thermally conductive at temperatures above about 0.2 K, and is insulating if either end of the switch is below about 0.15 K. The "on" conductance (7 mW/K at 0.25K) is limited by the surface area and gap between the copper leaves, the saturated vapor pressure of the He-3, and the Kapitza boundary resistance between the He-3 and the copper. The "off" conductance is determined by the helium containment shell which physically supports the two conductive ends. We have also designed and are building passive gas gap heat switches which will passively turn off near 1 K and 4 K. For these switches we rely on the rapidly changing vapor pressure of He-4 above neon or copper substrates, respectively, when the coverage is less than one monolayer. The different binding energies of the He-4 to the neon or copper give rise to the different temperatures where the switches transition between the on and off states.

Shirron, P. J.