Engineering Papers⌕ Search

Engineering topics

Konno, T.

Publications and source records attributed to Konno, T..

At least 55 records · Page 3

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of branching fractions and asymmetry parameters of $ {\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0} $, $ {\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0} $, and $ {\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -} $ decays at Belle

Using a data sample of 980 fb -1 collected with the Belle detector at the KEKB asymmetric-energy e + e - collider, we study the processes of ${\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}$, ${\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0}$, and ${\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -}$ for the first time. The relative branching ratios to the normalization mode of ${\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}$ are measured to be ${\displaystyle \begin{array}{c}\mathcal{B}\left({\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}\right)/\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)=0.18\pm 0.02\left(\mathrm{stat}.\right)\pm 0.01\left(\mathrm{syst}.\right),\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0}\right)/\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)=0.69\pm 0.03\left(\mathrm{stat}.\right)\pm 0.03\left(\mathrm{syst}.\right),\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -}\right)/\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)=0.34\pm 0.06\left(\mathrm{stat}.\right)\pm 0.02\left(\mathrm{syst}.\right),\end{array}}$ where the uncertainties are statistical and systematic, respectively. We obtain ${\displaystyle \begin{array}{c}\mathcal{B}\left({\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}\right)=\left(3.3\pm 0.3\left(\mathrm{stat}.\right)\pm 0.2\left(\mathrm{syst}.\right)\pm 1.0\left(\mathrm{ref}.\right)\right)\times {10}^{-3},\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0}\right)=\left(12.4\pm 0.5\left(\mathrm{stat}.\right)\pm 0.5\left(\mathrm{syst}.\right)\pm 3.6\left(\mathrm{ref}.\right)\right)\times {10}^{-3},\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast 0}\right)=\left(6.1\pm 1.0\left(\mathrm{stat}.\right)\pm 0.4\left(\mathrm{syst}.\right)\pm 1.8\left(\mathrm{ref}.\right)\right)\times {10}^{-3},\end{array}}$ where the uncertainties are statistical, systematic, and from $\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)$, respectively. The asymmetry parameters $\alpha \left({\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}\right)$ and $\alpha \left({\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -}\right)$ are 0.15 ± 0.22(stat.) ± 0.04(syst.) and -0.52 ± 0.30(stat.) ± 0.02(syst.), respectively, where the uncertainties are statistical followed by systematic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the energy dependence of the e+e- → $ B\overline{B} $, $ B{\overline{B}}^{\ast } $ and $ {B}^{\ast }{\overline{B}}^{\ast } $ exclusive cross sections

We report the first measurement of the exclusive cross sections e + e - → $B\overline{B}$, e + e - → $B{\overline{B}}^{\ast }$, and e + e - → ${B}^{\ast }{\overline{B}}^{\ast }$ in the energy range from 10.63 GeV to 11.02 GeV. The B mesons are fully reconstructed in a large number of hadronic final states and the three channels are identified using a beam-constrained-mass variable. The shapes of the exclusive cross sections show oscillatory behavior with several maxima and minima. The results are obtained using data collected by the Belle experiment at the KEKB asymmetric-energy e + e - collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for the dark photon in B 0 → A'A', A' → e + e – , μ + μ – , and π + π – decays at Belle

We present a search for the dark photon A' in the B 0 → A'A' decays, where A' subsequently decays to e + e – , μ + μ – , and π + π – . The search is performed by analyzing 772 × 10 6 $B$$\overline{B}$ events collected by the Belle detector at the KEKB e + e – energy-asymmetric collider at the Υ(4S) resonance. No signal is found in the dark photon mass range 0.01 GeV/c 2 ≤ m A' ≤ 2.62 GeV/c 2 , and we set upper limits of the branching fraction of B0 → A'A' at the 90% confidence level. The products of branching fractions, B(B 0 →A'A')×B(A'→e + e – ) 2 and B(B 0 →A'A')×B(A'→μ + μ – ) 2 , have limits of the order of 10 –8 depending on the A' mass. Furthermore, considering A' decay rate to each pair of charged particles, the upper limits of B(B 0 →A'A') are of the order of 10 –8 –10 –5 . From the upper limits of B(B 0 →A'A'), we obtain the Higgs portal coupling for each assumed dark photon and dark Higgs mass. The Higgs portal couplings are of the order of 10 –2 –10 –1 at m h' ≃m B 0 ± 40 MeV/c 2 and 10 –1 –1 at m h' ≃m B 0 ± 3 GeV/c 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of PMTs for the JSNS 2 experiment

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate γ-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS 2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS 2 did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS 2 experiment, and 120 PMTs were installed in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of θ 13 From Delayed Neutron Capture on Hydrogen in the Double Chooz Experiment

The Double Chooz experiment has determined the value of the neutrino oscillation parameter θ 13 from an analysis of inverse beta decay interactions with neutron capture on hydrogen. The analysis presented here uses a three times larger fiducial volume than the standard Double Chooz assessment, which is restricted to a region doped with gadolinium (Gd), yielding an exposure of 113.1 GW-ton-years. The data sample used in this analysis is distinct from that of the Gd analysis, and the systematic uncertainties are also largely independent, with some exceptions, such as the reactor neutrino flux prediction. A combined rate- and energy-dependent fit finds sin 2 2θ 13 = 0.097±0.034(stat.)±0.034(syst.), excluding the no-oscillation hypothesis at 2.0σ. This result is consistent with previous measurements of sin 2 2θ 13 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗